title: "Trina Solar TSM-300DD05A08(II) Specs (300.0W, 39.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-300dd05a08-ii/
description: "CEC datasheet for Trina Solar TSM-300DD05A08(II): 300.0W STC, 39.9V Voc, 27-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Trina Solar TSM-300DD05A08(II) — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-300DD05A08(II) is a 300.0 W STC (270.6 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.33% efficiency, 39.9 V Voc at 25 C, and 44.75 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 300.0 W

- **PTC Wattage** : 270.6 W

- **Voc @ 25C** : 39.9 V

- **Efficiency** : 18.33%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-300DD05A08(II) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-300DD05A08(II) (Mono-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-300DD05A08(II) need 20 panels for 6 kW or 27 panels (476 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (476 sq ft). Under NEC 690.7(A), beta_Voc (-0.347%/C) pushes open-circuit voltage to 44.75 V at 14 F and 46.13 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Trina Solar TSM-300DD05A08(II) Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-300DD05A08(II) (300.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Trina Solar TSM-300DD05A08(II)?

Relative ranking of Trina Solar TSM-300DD05A08(II) across nameplate watts, 90.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Trina Solar TSM-300DD05A08(II)?

Summary of Trina Solar TSM-300DD05A08(II) output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,498 / 21,677

### 300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,597

### 18.33% Aperture Efficiency

Power density 183.3 W/m2 (1.58 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.75 V at -10 C (581.8 V string) and 46.13 V at -20 C (13 max).

 8 kW Reference Array

### 27 Panels = 8,100 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 15.04 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.9 * (1 + (-0.347/100) * (-10 - 25)) = 44.75 V | OCPD = 1.56 * 9.64 = 15.04 A

Inputs from CEC Modules.csv for Trina Solar TSM-300DD05A08(II): Voc=39.9 V, beta_Voc=-0.347%/C, Isc=9.64 A, STC=300.0 W, Area=1.637 m2.

**Result:** 13 panels max on 600 V (581.8 V); 27 panels for 8 kW (476 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-300DD05A08(II)?

Complete CEC test sheet for Trina Solar TSM-300DD05A08(II) including Isc (9.64 A), Voc (39.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-300DD05A08(II).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 270.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.6 V / 9.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.347 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.33% (1.637 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-300DD05A08(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-300DD05A08(II).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.0 kW | 352 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 27 | 8.1 kW | 476 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 34 | 10.2 kW | 599 sq ft | $2,553 | $4,317 |

## How Many Trina Solar TSM-300DD05A08(II) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-300DD05A08(II) (39.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.9V and beta_Voc=-0.347%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.13 V | 13 panels | 599.7 V | 21 panels |
| **-10 C (14 F)** | 44.75 V | 13 panels | 581.8 V | 22 panels |
| **0 C (32 F)** | 43.36 V | 13 panels | 563.7 V | 23 panels |
| **25 C (77 F STC)** | 39.9 V | 15 panels | 598.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-300DD05A08(II)?

Four comparable CEC modules such as Enphase Energy Inc XACM-IQ7-LR6-60PB-300M (300.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Enphase Energy Inc XACM-IQ7-LR6-60PB-300M**](https://epri-peac.com/solar-equipment/modules/enphase-energy-inc/enphase-energy-inc-xacm-iq7-lr6-60pb-300m/) Enphase Energy Inc | 300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| [**FreeVolt PV-GRAF-60M6-300/M**](https://epri-peac.com/solar-equipment/modules/freevolt/freevolt-pv-graf-60m6-300-m/) FreeVolt | 300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| [**CertainTeed CT300M10-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m10-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| [**CertainTeed CT300M11-03**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct300m11-03/) CertainTeed | 300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-300DD05A08(II)?

Evaluate Trina Solar TSM-300DD05A08(II) (300.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-300DD05A08(II) reaches 46.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (476 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-300DD05A08(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-300DD05A08(II) 8 kW Residential Fit

Needs 27 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-300DD05A08(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Trina Solar TSM-300DD05A08(II) PTC wattage (270.6 W) lower than STC (300.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.6 W PTC (90.2% retention) across Trina Solar TSM-300DD05A08(II)'s 1.637 m2 aperture.

### Who should skip Trina Solar TSM-300DD05A08(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Trina Solar TSM-300DD05A08(II) panels (476 sq ft) leave unusable roof gaps vs. Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.

### What is the 1,000 V commercial string limit for Trina Solar TSM-300DD05A08(II)?

On 1,000 V commercial inverters at -10 C (44.75 V cold Voc), Trina Solar TSM-300DD05A08(II) fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-300DD05A08(II).

## Related Pages

Compare Trina Solar equipment, Enphase Energy Inc XACM-IQ7-LR6-60PB-300M specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-300DD05A08(II).

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)