title: "Trina Solar TSM-295PE06HT0 Specs (295.0W, 39.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-295pe06ht0/
description: "CEC datasheet for Trina Solar TSM-295PE06HT0: 295.0W STC, 39.5V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Trina Solar TSM-295PE06HT0 — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-295PE06HT0 is a 295.0 W STC (271.5 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 17.77% efficiency, 39.5 V Voc at 25 C, and 43.65 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 271.5 W

- **Voc @ 25C** : 39.5 V

- **Efficiency** : 17.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-295PE06HT0 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-295PE06HT0 handles rooftop heat (271.5 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-295PE06HT0 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 177.7 W/m2 (2.14 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W), this model holds strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677). Lower 39.5 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 15.09 A overcurrent floor served by a 20 A breaker.

## Where Does Trina Solar TSM-295PE06HT0 Fall Across Listed CEC Models?

Where Trina Solar TSM-295PE06HT0 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Trina Solar TSM-295PE06HT0?

Percentile placement of Trina Solar TSM-295PE06HT0 across power density (177.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Trina Solar TSM-295PE06HT0?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-295PE06HT0 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,438

### 17.77% Aperture Efficiency

Power density 177.7 W/m2 (2.14 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.65 V at -10 C (567.4 V string) and 44.83 V at -20 C (13 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 46.5 m2 (500 sq ft) producing 7,602 W PTC; NEC 690.8 OCPD floor is 15.09 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.5 * (1 + (-0.3/100) * (-10 - 25)) = 43.65 V | OCPD = 1.56 * 9.67 = 15.09 A

Inputs from CEC Modules.csv for Trina Solar TSM-295PE06HT0: Voc=39.5 V, beta_Voc=-0.3%/C, Isc=9.67 A, STC=295.0 W, Area=1.66 m2.

**Result:** 13 panels max on 600 V (567.4 V); 28 panels for 8 kW (500 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-295PE06HT0?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-295PE06HT0.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-295PE06HT0.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 271.5 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.1 V / 9.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.3 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.77% (1.66 m2) | Array roof footprint density |
| **Cell Count & Technology** | 40 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-295PE06HT0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-295PE06HT0 (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 375 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 500 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 608 sq ft | $2,510 | $4,245 |

## How Many Trina Solar TSM-295PE06HT0 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-295PE06HT0 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.5V and beta_Voc=-0.3%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.83 V | 13 panels | 582.8 V | 22 panels |
| **-10 C (14 F)** | 43.65 V | 13 panels | 567.4 V | 22 panels |
| **0 C (32 F)** | 42.46 V | 14 panels | 594.4 V | 23 panels |
| **25 C (77 F STC)** | 39.5 V | 15 panels | 592.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-295PE06HT0?

Alternative CEC solar modules from competing brands near Trina Solar TSM-295PE06HT0 (295.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/60295**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60295/) GCL System Integration Technology Co Ltd | 295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| [**CSI Solar Co Ltd CS3K-295MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-295ms/) CSI Solar Co Ltd | 295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| [**AXITEC AC-290M/60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-60s/) AXITEC | 290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |
| [**AXITEC AC-290M/60V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-290m-60v/) AXITEC | 290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-295PE06HT0?

Evaluate Trina Solar TSM-295PE06HT0 (295.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-295PE06HT0 reaches 44.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 500 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (500 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-295PE06HT0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-295PE06HT0 8 kW Residential Fit

Needs 28 modules (500 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-295PE06HT0 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-295PE06HT0?

Multiplying Trina Solar TSM-295PE06HT0's 9.67 A short-circuit current by 1.56 equals 15.09 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Trina Solar TSM-295PE06HT0 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.65 V cold Voc at 14 F and handles 9.67 A Isc; string inverters cap Trina Solar TSM-295PE06HT0 at 13 panels on 600 V.

### Is Trina Solar TSM-295PE06HT0 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-295PE06HT0 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare Trina Solar equipment, GCL System Integration Technology Co Ltd GCL-M6/60295 specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-295PE06HT0.

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)