---
title: "Trina Solar TSM-260PA05A08 Specs (260.0W, 38.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-260pa05a08/
description: "CEC datasheet for Trina Solar TSM-260PA05A08: 260.0W STC, 38.2V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Trina Solar TSM-260PA05A08 — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-260PA05A08 is a 260.0 W STC (238.5 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.07% efficiency, 38.2 V Voc at 25 C, and 42.61 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 238.5 W

- **Voc @ 25C** : 38.2 V

- **Efficiency** : 16.07%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-260PA05A08 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-260PA05A08 handles rooftop heat (238.5 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-260PA05A08 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). Compared against Centrosolar America DM60 260 (260.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Lower 38.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.07 A overcurrent floor served by a 15 A breaker.

## Where Does Trina Solar TSM-260PA05A08 Fall Across Listed CEC Models?

Where Trina Solar TSM-260PA05A08 (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Trina Solar TSM-260PA05A08?

Percentile placement of Trina Solar TSM-260PA05A08 across power density (160.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Trina Solar TSM-260PA05A08?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-260PA05A08 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,013

### 16.07% Aperture Efficiency

Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.61 V at -10 C (596.5 V string) and 43.87 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 50.2 m2 (540 sq ft) producing 7,394 W PTC; NEC 690.8 OCPD floor is 14.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.2 * (1 + (-0.33/100) * (-10 - 25)) = 42.61 V | OCPD = 1.56 * 9.02 = 14.07 A

Inputs from CEC Modules.csv for Trina Solar TSM-260PA05A08: Voc=38.2 V, beta_Voc=-0.33%/C, Isc=9.02 A, STC=260.0 W, Area=1.618 m2.

**Result:** 14 panels max on 600 V (596.5 V); 31 panels for 8 kW (540 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-260PA05A08?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-260PA05A08.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-260PA05A08.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 238.5 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.02 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.3 V / 8.31 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.07% (1.618 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-260PA05A08 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-260PA05A08 (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 418 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 540 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 679 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-260PA05A08 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Trina Solar TSM-260PA05A08 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Trina Solar TSM-250PA05A08** | 250.0 W | 229.1 W | 37.8 V | 30.5 V | 15.45% |
| **Trina Solar TSM-255PA05A08** | 255.0 W | 233.8 W | 38.0 V | 30.9 V | 15.76% |
| **Trina Solar TSM-260PA05A08** | 260.0 W | 238.5 W | 38.2 V | 31.3 V | 16.07% |
| **Trina Solar TSM-265PA05A08** | 265.0 W | 243.2 W | 38.3 V | 31.6 V | 16.37% |
| **Trina Solar TSM-270PA05A08** | 270.0 W | 247.9 W | 38.5 V | 31.9 V | 16.68% |

## How Many Trina Solar TSM-260PA05A08 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-260PA05A08 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.2V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.87 V | 13 panels | 570.3 V | 22 panels |
| **-10 C (14 F)** | 42.61 V | 14 panels | 596.5 V | 23 panels |
| **0 C (32 F)** | 41.35 V | 14 panels | 578.9 V | 24 panels |
| **25 C (77 F STC)** | 38.2 V | 15 panels | 573.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-260PA05A08?

Alternative CEC solar modules from competing brands near Trina Solar TSM-260PA05A08 (260.0 W), including Centrosolar America DM60 260.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM60 260**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm60-260/) Centrosolar America | 260.0 W | Tie (0 W) | 38.2 V | 15.86% | 90.8% |
| [**Centrosolar America DP60 260**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-260/) Centrosolar America | 260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |
| [**BYD Company Limited BYD 260P6C-30**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-260p6c-30/) BYD Company Limited | 260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| [**BYD Company Limited BYD260P6K-30**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd260p6k-30/) BYD Company Limited | 260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-260PA05A08?

Evaluate Trina Solar TSM-260PA05A08 (260.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-260PA05A08 reaches 43.87 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 540 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (540 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-260PA05A08 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-260PA05A08 8 kW Residential Fit

Needs 31 modules (540 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 260.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-260PA05A08 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-260PA05A08?

Multiplying Trina Solar TSM-260PA05A08's 9.02 A short-circuit current by 1.56 equals 14.07 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Trina Solar TSM-260PA05A08 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.61 V cold Voc at 14 F and handles 9.02 A Isc; string inverters cap Trina Solar TSM-260PA05A08 at 14 panels on 600 V.

### Is Trina Solar TSM-260PA05A08 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-260PA05A08 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Trina Solar equipment, Centrosolar America DM60 260 specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-260PA05A08.

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)
