title: "Trina Solar TSM-180DA01 Specs (180.0W, 44.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-180da01/
description: "CEC datasheet for Trina Solar TSM-180DA01: 180.0W STC, 44.2V Voc, 45-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Trina Solar TSM-180DA01 — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-180DA01 is a 180.0 W STC (163.1 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 14.26% efficiency, 44.2 V Voc at 25 C, and 49.15 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 180.0 W

- **PTC Wattage** : 163.1 W

- **Voc @ 25C** : 44.2 V

- **Efficiency** : 14.26%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-180DA01 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-180DA01 handles rooftop heat (163.1 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-180DA01 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 142.6 W/m2 (5.65 percentage points below 19.91% CEC median). Compared against Guangdong Golden Glass Technologies GG180S1-36/1589x807 (180.0 W), this model holds typical 90.6% PTC-to-STC thermal output (163.1 W real-world rating). Mid-range 44.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.35 A overcurrent floor served by a 15 A breaker.

## Where Does Trina Solar TSM-180DA01 Fall Across Listed CEC Models?

Where Trina Solar TSM-180DA01 (180.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Trina Solar TSM-180DA01?

Percentile placement of Trina Solar TSM-180DA01 across power density (142.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Trina Solar TSM-180DA01?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-180DA01 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #21,232 / 21,677

### 180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,651

### 14.26% Aperture Efficiency

Power density 142.6 W/m2 (5.65 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.15 V at -10 C (589.8 V string) and 50.56 V at -20 C (11 max).

 8 kW Reference Array

### 45 Panels = 8,100 W STC

Occupies 56.8 m2 (611 sq ft) producing 7,340 W PTC; NEC 690.8 OCPD floor is 8.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.32/100) * (-10 - 25)) = 49.15 V | OCPD = 1.56 * 5.35 = 8.35 A

Inputs from CEC Modules.csv for Trina Solar TSM-180DA01: Voc=44.2 V, beta_Voc=-0.32%/C, Isc=5.35 A, STC=180.0 W, Area=1.262 m2.

**Result:** 12 panels max on 600 V (589.8 V); 45 panels for 8 kW (611 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-180DA01?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-180DA01.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-180DA01.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 163.1 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.8 V / 4.9 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.32 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.26% (1.262 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-180DA01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-180DA01 (180.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 34 | 6.12 kW | 462 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 45 | 8.1 kW | 611 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 56 | 10.08 kW | 761 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-180DA01 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-180DA01 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Trina Solar TSM-175DA01** | 175.0 W | 158.5 W | 43.9 V | 36.2 V | 13.86% |
| **Trina Solar TSM-180DA01** | 180.0 W | 163.1 W | 44.2 V | 36.8 V | 14.26% |
| **Trina Solar TSM-185DA01** | 185.0 W | 164.3 W | 44.5 V | 37.5 V | 14.66% |

## How Many Trina Solar TSM-180DA01 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-180DA01 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.2V and beta_Voc=-0.32%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.56 V | 11 panels | 556.2 V | 19 panels |
| **-10 C (14 F)** | 49.15 V | 12 panels | 589.8 V | 20 panels |
| **0 C (32 F)** | 47.74 V | 12 panels | 572.9 V | 20 panels |
| **25 C (77 F STC)** | 44.2 V | 13 panels | 574.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-180DA01?

Alternative CEC solar modules from competing brands near Trina Solar TSM-180DA01 (180.0 W), including Guangdong Golden Glass Technologies GG180S1-36/1589x807.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Guangdong Golden Glass Technologies GG180S1-36/1589x807**](https://epri-peac.com/solar-equipment/modules/guangdong-golden-glass-technologies/guangdong-golden-glass-technologies-gg180s1-36-1589x807/) Guangdong Golden Glass Technologies | 180.0 W | Tie (0 W) | 44.2 V | 14.04% | 90.8% |
| [**Alps Technology ATI-S572-180**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-s572-180/) Alps Technology | 180.0 W | Tie (0 W) | 44.06 V | 13.98% | 86.5% |
| [**Anji Technology AJP-S572-180**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-s572-180/) Anji Technology | 180.0 W | Tie (0 W) | 44.06 V | 13.84% | 86.5% |
| [**Solarbest Energy-Tech (Zhejiang) ZSB-M180(125)**](https://epri-peac.com/solar-equipment/modules/solarbest-energy-tech-zhejiang/solarbest-energy-tech-zhejiang-zsb-m180-125/) Solarbest Energy-Tech (Zhejiang) | 180.0 W | Tie (0 W) | 44.35 V | 14.1% | 89.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-180DA01?

Evaluate Trina Solar TSM-180DA01 (180.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-180DA01 reaches 50.56 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 611 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (611 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-180DA01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-180DA01 8 kW Residential Fit

Needs 45 modules (611 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Guangdong Golden Glass Technologies GG180S1-36/1589x807.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-180DA01 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-180DA01?

Multiplying Trina Solar TSM-180DA01's 5.35 A short-circuit current by 1.56 equals 8.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Trina Solar TSM-180DA01 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.15 V cold Voc at 14 F and handles 5.35 A Isc; string inverters cap Trina Solar TSM-180DA01 at 12 panels on 600 V.

### Is Trina Solar TSM-180DA01 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-180DA01 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Trina Solar equipment, Guangdong Golden Glass Technologies GG180S1-36/1589x807 specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-180DA01.

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)