---
title: "Toledo Solar Inc TS1 Specs (115.0W, 87.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/toledo-solar-inc/toledo-solar-inc-ts1/
description: "CEC datasheet for Toledo Solar Inc TS1: 115.0W STC, 87.1V Voc, 70-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Toledo Solar Inc TS1 — CEC Solar Module Specifications

Manufacturer: [**Toledo Solar Inc**](https://epri-peac.com/solar-equipment/brands/toledo-solar-inc/) Registry: **CEC Verified Engineering Specification**

Toledo Solar Inc TS1 is a 115.0 W STC (106.8 W PTC) CdTe solar module ranking #21,511 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.97% efficiency, 87.1 V Voc at 25 C, and 96.31 V cold Voc at -10 C (6 panels max per 600 V string).

- **STC Wattage** : 115.0 W

- **PTC Wattage** : 106.8 W

- **Voc @ 25C** : 87.1 V

- **Efficiency** : 15.97%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Toledo Solar Inc TS1 Compare Against Peer CEC Listings?

How Toledo Solar Inc Toledo Solar Inc TS1 handles rooftop heat (106.8 W PTC), 8 kW sizing, and cold winter string voltage.

Toledo Solar Inc builds the Toledo Solar Inc TS1 (CdTe) as a compact residential or specialty off-grid module delivering 159.7 W/m2 (3.94 percentage points below 19.91% CEC median). Compared against First Solar Inc FS-4115-3 (115.0 W), this model holds strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Higher 87.1 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 2.82 A overcurrent floor served by a 15 A breaker.

## Where Does Toledo Solar Inc TS1 Fall Across Listed CEC Models?

Where Toledo Solar Inc TS1 (115.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Toledo Solar Inc TS1?

Percentile placement of Toledo Solar Inc TS1 across power density (159.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Toledo Solar Inc TS1?

Four critical engineering numbers homeowners and solar installers check first when reviewing Toledo Solar Inc TS1 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #21,511 / 21,677

### 115.0 W STC · Higher Than 0.7%

115.0 W STC (-270.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,237

### 15.97% Aperture Efficiency

Power density 159.7 W/m2 (3.94 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 6 Panels Max @ -10 C (600 V)

Cold Voc reaches 96.31 V at -10 C (577.9 V string) and 98.94 V at -20 C (6 max).

 8 kW Reference Array

### 70 Panels = 8,050 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 2.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.1 * (1 + (-0.302/100) * (-10 - 25)) = 96.31 V | OCPD = 1.56 * 1.81 = 2.82 A

Inputs from CEC Modules.csv for Toledo Solar Inc TS1: Voc=87.1 V, beta_Voc=-0.302%/C, Isc=1.81 A, STC=115.0 W, Area=0.72 m2.

**Result:** 6 panels max on 600 V (577.9 V); 70 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Toledo Solar Inc TS1?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Toledo Solar Inc TS1.

Official California Energy Commission (NREL SAM) test parameters for Toledo Solar Inc TS1.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 115.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 106.8 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 87.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 1.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 69.0 V / 1.7 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.302 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.97% (0.72 m2) | Array roof footprint density |
| **Cell Count & Technology** | 108 cells (CdTe) | Monofacial backsheet |

## How Many Toledo Solar Inc TS1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Toledo Solar Inc TS1 (115.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 53 | 6.09 kW | 411 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 70 | 8.05 kW | 543 sq ft | $2,015 | $3,407 |
| **10 kW Class** | 87 | 10.01 kW | 674 sq ft | $2,505 | $4,236 |

## How Many Toledo Solar Inc TS1 Modules Fit in a Cold-Weather String?

Maximum series module counts for Toledo Solar Inc TS1 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=87.1V and beta_Voc=-0.302%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 98.94 V | 6 panels | 593.6 V | 10 panels |
| **-10 C (14 F)** | 96.31 V | 6 panels | 577.9 V | 10 panels |
| **0 C (32 F)** | 93.68 V | 6 panels | 562.1 V | 10 panels |
| **25 C (77 F STC)** | 87.1 V | 6 panels | 522.6 V | 11 panels |

## Which Cross-Brand Solar Modules Compare Closest to Toledo Solar Inc TS1?

Alternative CEC solar modules from competing brands near Toledo Solar Inc TS1 (115.0 W), including First Solar Inc FS-4115-3.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**First Solar Inc FS-4115-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4115-3/) First Solar Inc | 115.0 W | Tie (0 W) | 87.6 V | 15.97% | 93.3% |
| [**First Solar Inc FS-4115A-3**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4115a-3/) First Solar Inc | 115.0 W | Tie (0 W) | 87.6 V | 15.97% | 93.3% |
| [**First Solar Inc FS-4115-2**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4115-2/) First Solar Inc | 115.0 W | Tie (0 W) | 87.8 V | 15.97% | 91.5% |
| [**First Solar Inc FS-4115A-2**](https://epri-peac.com/solar-equipment/modules/first-solar-inc/first-solar-inc-fs-4115a-2/) First Solar Inc | 115.0 W | Tie (0 W) | 87.8 V | 15.97% | 91.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Toledo Solar Inc TS1?

Evaluate Toledo Solar Inc TS1 (115.0 W STC, 87.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Toledo Solar Inc TS1 reaches 98.94 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 70 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Toledo Solar Inc TS1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Toledo Solar Inc TS1 8 kW Residential Fit

Needs 70 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4115-3.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 106.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Toledo Solar Inc TS1 by Toledo Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Toledo Solar Inc TS1?

Multiplying Toledo Solar Inc TS1's 1.81 A short-circuit current by 1.56 equals 2.82 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Toledo Solar Inc TS1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 96.31 V cold Voc at 14 F and handles 1.81 A Isc; string inverters cap Toledo Solar Inc TS1 at 6 panels on 600 V.

### Is Toledo Solar Inc TS1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Toledo Solar Inc TS1 rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

## Related Pages

Compare Toledo Solar Inc equipment, First Solar Inc FS-4115-3 specs, utility payback rates, and NEC string calculators alongside Toledo Solar Inc TS1.

[All Toledo Solar Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/toledo-solar-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Toledo Solar Inc

- [All Toledo Solar Inc Specs](https://epri-peac.com/solar-equipment/brands/toledo-solar-inc/)
