title: "Thornova Solar TS-SBT60(510) Specs (510.0W, 44.02V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-sbt60-510/
description: "CEC datasheet for Thornova Solar TS-SBT60(510): 510.0W STC, 44.02V Voc, 16-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-SBT60(510) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-SBT60(510) is a 510.0 W STC (485.7 W PTC) Mono-c-Si solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 23.83% efficiency, 44.02 V Voc at 25 C, and 47.58 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 510.0 W

- **PTC Wattage** : 485.7 W

- **Voc @ 25C** : 44.02 V

- **Efficiency** : 23.83%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-SBT60(510) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Thornova Solar TS-SBT60(510) (Mono-c-Si) residential solar systems.

Homeowners evaluating Thornova Solar TS-SBT60(510) need 12 panels for 6 kW or 16 panels (369 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (369 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.231%/C) pushes open-circuit voltage to 47.58 V at 14 F and 48.6 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Thornova Solar TS-SBT60(510) Fall Across Listed CEC Models?

Comparison of Thornova Solar TS-SBT60(510) (510.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Thornova Solar TS-SBT60(510)?

Relative ranking of Thornova Solar TS-SBT60(510) across nameplate watts, 95.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Thornova Solar TS-SBT60(510)?

Summary of Thornova Solar TS-SBT60(510) output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,386 / 21,677

### Top 20.5% STC Output

510.0 W STC (+125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #293

### 23.83% Aperture Efficiency

Power density 238.3 W/m2 (3.92 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.58 V at -10 C (571.0 V string) and 48.6 V at -20 C (12 max).

 8 kW Reference Array

### 16 Panels = 8,160 W STC

Occupies 34.2 m2 (369 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 21.98 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.02 * (1 + (-0.231/100) * (-10 - 25)) = 47.58 V | OCPD = 1.56 * 14.09 = 21.98 A

Inputs from CEC Modules.csv for Thornova Solar TS-SBT60(510): Voc=44.02 V, beta_Voc=-0.231%/C, Isc=14.09 A, STC=510.0 W, Area=2.14 m2.

**Result:** 12 panels max on 600 V (571.0 V); 16 panels for 8 kW (369 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-SBT60(510)?

Complete CEC test sheet for Thornova Solar TS-SBT60(510) including Isc (14.09 A), Voc (44.02 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-SBT60(510).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 510.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 485.7 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.61 V / 13.57 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.83% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Thornova Solar TS-SBT60(510) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Thornova Solar TS-SBT60(510).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.12 kW | 276 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 16 | 8.16 kW | 369 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 20 | 10.2 kW | 461 sq ft | $2,553 | $4,317 |

## How Many Thornova Solar TS-SBT60(510) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Thornova Solar TS-SBT60(510) (44.02 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.02V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 48.6 V | 12 panels | 583.2 V | 20 panels |
| **-10 C (14 F)** | 47.58 V | 12 panels | 571.0 V | 21 panels |
| **0 C (32 F)** | 46.56 V | 12 panels | 558.7 V | 21 panels |
| **25 C (77 F STC)** | 44.02 V | 13 panels | 572.3 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SBT60(510)?

Four comparable CEC modules such as Auxin Solar AXN10M510W (510.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN10M510W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m510w/) Auxin Solar | 510.0 W | Tie (0 W) | 44.3 V | 23.72% | 91.9% |
| [**CSI Solar Co Ltd CS61-60TM-510H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-510h/) CSI Solar Co Ltd | 510.0 W | Tie (0 W) | 43.6 V | 23.29% | 94.8% |
| [**Elin Energy (Sirius PV) ELNSM66M-HC-510**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm66m-hc-510/) Elin Energy (Sirius PV) | 510.0 W | Tie (0 W) | 46.05 V | 21.61% | 94.3% |
| [**Elin Energy (Sirius PV) ELNSM66M-HC-LV-510**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm66m-hc-lv-510/) Elin Energy (Sirius PV) | 510.0 W | Tie (0 W) | 46.05 V | 21.61% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SBT60(510)?

Evaluate Thornova Solar TS-SBT60(510) (510.0 W STC, 44.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SBT60(510) reaches 48.6 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 369 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (369 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SBT60(510) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-SBT60(510) 8 kW Residential Fit

Needs 16 modules (369 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN10M510W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 485.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-SBT60(510) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Thornova Solar TS-SBT60(510) PTC wattage (485.7 W) lower than STC (510.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 485.7 W PTC (95.2% retention) across Thornova Solar TS-SBT60(510)'s 2.14 m2 aperture.

### Who should skip Thornova Solar TS-SBT60(510) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 Thornova Solar TS-SBT60(510) panels (369 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M510W.

### What is the 1,000 V commercial string limit for Thornova Solar TS-SBT60(510)?

On 1,000 V commercial inverters at -10 C (47.58 V cold Voc), Thornova Solar TS-SBT60(510) fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-SBT60(510).

## Related Pages

Compare Thornova Solar equipment, Auxin Solar AXN10M510W specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-SBT60(510).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)