title: "Thornova Solar TS-SBT60(490) Specs (490.0W, 43.42V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-sbt60-490/
description: "CEC datasheet for Thornova Solar TS-SBT60(490): 490.0W STC, 43.42V Voc, 17-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-SBT60(490) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-SBT60(490) is a 490.0 W STC (466.2 W PTC) Mono-c-Si solar module ranking #4,659 of 21,677 CEC listings (top 21.8%; higher than 78.2% of peers). It delivers 22.9% efficiency, 43.42 V Voc at 25 C, and 46.93 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 490.0 W

- **PTC Wattage** : 466.2 W

- **Voc @ 25C** : 43.42 V

- **Efficiency** : 22.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-SBT60(490) Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-SBT60(490) handles rooftop heat (466.2 W PTC), 8 kW sizing, and cold winter string voltage.

Thornova Solar builds the Thornova Solar TS-SBT60(490) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 229.0 W/m2 (2.99 percentage points above 19.91% CEC median). Compared against DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M (490.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Mid-range 43.42 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.43 A overcurrent floor served by a 25 A breaker.

## Where Does Thornova Solar TS-SBT60(490) Fall Across Listed CEC Models?

Where Thornova Solar TS-SBT60(490) (490.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-SBT60(490)?

Percentile placement of Thornova Solar TS-SBT60(490) across power density (229.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Thornova Solar TS-SBT60(490)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-SBT60(490) specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #4,659 / 21,677

### Top 21.8% STC Output

490.0 W STC (+105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,295

### 22.9% Aperture Efficiency

Power density 229.0 W/m2 (2.99 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.93 V at -10 C (563.2 V string) and 47.93 V at -20 C (12 max).

 8 kW Reference Array

### 17 Panels = 8,330 W STC

Occupies 36.4 m2 (392 sq ft) producing 7,925 W PTC; NEC 690.8 OCPD floor is 21.43 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.42 * (1 + (-0.231/100) * (-10 - 25)) = 46.93 V | OCPD = 1.56 * 13.74 = 21.43 A

Inputs from CEC Modules.csv for Thornova Solar TS-SBT60(490): Voc=43.42 V, beta_Voc=-0.231%/C, Isc=13.74 A, STC=490.0 W, Area=2.14 m2.

**Result:** 12 panels max on 600 V (563.2 V); 17 panels for 8 kW (392 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-SBT60(490)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-SBT60(490).

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-SBT60(490).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 490.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 466.2 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.42 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.2 V / 13.18 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.9% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Thornova Solar TS-SBT60(490) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-SBT60(490) (490.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.37 kW | 299 sq ft | $1,594 | $2,696 |
| **8 kW Class** | 17 | 8.33 kW | 392 sq ft | $2,085 | $3,525 |
| **10 kW Class** | 21 | 10.29 kW | 484 sq ft | $2,575 | $4,355 |

## How Many Thornova Solar TS-SBT60(490) Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-SBT60(490) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.42V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 47.93 V | 12 panels | 575.2 V | 20 panels |
| **-10 C (14 F)** | 46.93 V | 12 panels | 563.2 V | 21 panels |
| **0 C (32 F)** | 45.93 V | 13 panels | 597.1 V | 21 panels |
| **25 C (77 F STC)** | 43.42 V | 13 panels | 564.5 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SBT60(490)?

Alternative CEC solar modules from competing brands near Thornova Solar TS-SBT60(490) (490.0 W), including DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M**](https://epri-peac.com/solar-equipment/modules/dongguan-sunworth-solar-energy-co-ltd/dongguan-sunworth-solar-energy-co-ltd-sw490m/) DONGGUAN SUNWORTH SOLAR ENERGY CO LTD | 490.0 W | Tie (0 W) | 44.21 V | 25.79% | 95.0% |
| [**Hanersun Energy Co Ltd HN18N-60HT485W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-60ht485w/) Hanersun Energy Co Ltd | 485.0 W | -5.0 W | 43.0 V | 22.99% | 94.9% |
| [**Auxin Solar AXN10M485B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485b/) Auxin Solar | 485.0 W | -5.0 W | 43.98 V | 22.56% | 92.0% |
| [**Auxin Solar AXN10M485W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485w/) Auxin Solar | 485.0 W | -5.0 W | 43.98 V | 22.56% | 91.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SBT60(490)?

Evaluate Thornova Solar TS-SBT60(490) (490.0 W STC, 43.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SBT60(490) reaches 47.93 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 392 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (392 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SBT60(490) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-SBT60(490) 8 kW Residential Fit

Needs 17 modules (392 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 466.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-SBT60(490) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-SBT60(490)?

Multiplying Thornova Solar TS-SBT60(490)'s 13.74 A short-circuit current by 1.56 equals 21.43 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-SBT60(490) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 46.93 V cold Voc at 14 F and handles 13.74 A Isc; string inverters cap Thornova Solar TS-SBT60(490) at 12 panels on 600 V.

### Is Thornova Solar TS-SBT60(490) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-SBT60(490) rely on utility bill offset (~$2,085/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-SBT60(490).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)