---
title: "Thornova Solar TS-SBT54(440) Specs (440.0W, 39.03V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-sbt54-440/
description: "CEC datasheet for Thornova Solar TS-SBT54(440): 440.0W STC, 39.03V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-SBT54(440) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-SBT54(440) is a 440.0 W STC (418.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.68% efficiency, 39.03 V Voc at 25 C, and 42.19 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 418.6 W

- **Voc @ 25C** : 39.03 V

- **Efficiency** : 22.68%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-SBT54(440) Compare Against Peer CEC Listings?

Solar engineering breakdown for Thornova Solar TS-SBT54(440): PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-SBT54(440) stands 30.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Lower 39.03 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Thornova Solar TS-SBT54(440) Fall Across Listed CEC Models?

Distribution marker showing Thornova Solar TS-SBT54(440) (440.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Thornova Solar TS-SBT54(440)?

Dataset percentiles tracking Thornova Solar TS-SBT54(440) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Thornova Solar TS-SBT54(440)?

Benchmark highlights for Thornova Solar TS-SBT54(440) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,656

### 22.68% Aperture Efficiency

Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.19 V at -10 C (590.7 V string) and 43.09 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,953 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.03 * (1 + (-0.231/100) * (-10 - 25)) = 42.19 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for Thornova Solar TS-SBT54(440): Voc=39.03 V, beta_Voc=-0.231%/C, Isc=13.73 A, STC=440.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (590.7 V); 19 panels for 8 kW (397 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-SBT54(440)?

Official CEC datasheet figures for Thornova Solar TS-SBT54(440) (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-SBT54(440).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 418.6 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.48 V / 13.15 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.231 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.68% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Thornova Solar TS-SBT54(440) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Thornova Solar TS-SBT54(440) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 292 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 397 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 480 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-SBT54(440) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-SBT54(440) (42.19 V at 14 F).

Computed from Voc=39.03V and beta_Voc=-0.231%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.09 V | 13 panels | 560.2 V | 23 panels |
| **-10 C (14 F)** | 42.19 V | 14 panels | 590.7 V | 23 panels |
| **0 C (32 F)** | 41.28 V | 14 panels | 577.9 V | 24 panels |
| **25 C (77 F STC)** | 39.03 V | 15 panels | 585.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SBT54(440)?

Competing CEC solar panels closest to Thornova Solar TS-SBT54(440) in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-108-MFN10-440W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MFN10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mfn10-440w/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 39.0 V | 22.68% | 95.1% |
| [**Bluesun Solar CoLtd BSM440M10-54HNH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm440m10-54hnh/) Bluesun Solar CoLtd | 440.0 W | Tie (0 W) | 38.9 V | 22.68% | 95.1% |
| [**AEG SOLAR ENERGY SRL ALPS54D30-440/TP**](https://epri-peac.com/solar-equipment/modules/aeg-solar-energy-srl/aeg-solar-energy-srl-alps54d30-440-tp/) AEG SOLAR ENERGY SRL | 440.0 W | Tie (0 W) | 39.5 V | 22.11% | 94.3% |
| [**CSI Solar Co Ltd CS61-54TM-440H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-54tm-440h/) CSI Solar Co Ltd | 440.0 W | Tie (0 W) | 38.5 V | 22.22% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SBT54(440)?

Evaluate Thornova Solar TS-SBT54(440) (440.0 W STC, 39.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SBT54(440) reaches 43.09 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SBT54(440) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-SBT54(440) 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MFN10-440W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 418.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-SBT54(440) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-SBT54(440)?

Multiplying Thornova Solar TS-SBT54(440)'s 13.73 A short-circuit current by 1.56 equals 21.42 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-SBT54(440) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.19 V cold Voc at 14 F and handles 13.73 A Isc; string inverters cap Thornova Solar TS-SBT54(440) at 14 panels on 600 V.

### Is Thornova Solar TS-SBT54(440) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-SBT54(440) rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, Aptos Solar Technology LLC DNA-108-MFN10-440W specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-SBT54(440).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)
