title: "Thornova Solar TS-SB60(440) Specs (440.0W, 41.18V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-sb60-440/
description: "CEC datasheet for Thornova Solar TS-SB60(440): 440.0W STC, 41.18V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Thornova Solar TS-SB60(440) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-SB60(440) is a 440.0 W STC (414.8 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.56% efficiency, 41.18 V Voc at 25 C, and 44.6 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 414.8 W

- **Voc @ 25C** : 41.18 V

- **Efficiency** : 20.56%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-SB60(440) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-SB60(440) (440.0 W STC) vs. Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 across 5,889 CEC Mono-c-Si solar modules.

Ranking #6,418 across 21,677 CEC solar panels (top 31.6%; higher than 68.4% of peers), Thornova Solar TS-SB60(440) operates as a modern high-density residential and light-commercial module sitting 30.0 W above the 410.0 W Mono-c-Si median. Mid-range 41.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677), 19 panels occupy 438 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Thornova Solar TS-SB60(440) Fall Across Listed CEC Models?

Plots Thornova Solar TS-SB60(440) at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-SB60(440)?

Benchmarks Thornova Solar TS-SB60(440) on STC wattage, thermal PTC/STC retention, and 20.56 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Thornova Solar TS-SB60(440)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-SB60(440) by Thornova Solar.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,260

### 20.56% Aperture Efficiency

Power density 205.6 W/m2 (0.65 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.6 V at -10 C (579.8 V string) and 45.57 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 40.7 m2 (438 sq ft) producing 7,881 W PTC; NEC 690.8 OCPD floor is 20.86 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.18 * (1 + (-0.237/100) * (-10 - 25)) = 44.6 V | OCPD = 1.56 * 13.37 = 20.86 A

Inputs from CEC Modules.csv for Thornova Solar TS-SB60(440): Voc=41.18 V, beta_Voc=-0.237%/C, Isc=13.37 A, STC=440.0 W, Area=2.14 m2.

**Result:** 13 panels max on 600 V (579.8 V); 19 panels for 8 kW (438 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-SB60(440)?

Laboratory test ratings recorded for Thornova Solar TS-SB60(440) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-SB60(440).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 414.8 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.33 V / 12.82 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.237 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.56% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Thornova Solar TS-SB60(440) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (438 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-SB60(440).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 322 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 438 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 530 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-SB60(440) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-SB60(440) (beta_Voc -0.237%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.18V and beta_Voc=-0.237%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.57 V | 13 panels | 592.4 V | 21 panels |
| **-10 C (14 F)** | 44.6 V | 13 panels | 579.8 V | 22 panels |
| **0 C (32 F)** | 43.62 V | 13 panels | 567.1 V | 22 panels |
| **25 C (77 F STC)** | 41.18 V | 14 panels | 576.5 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB60(440)?

Closest cross-brand CEC competitors to Thornova Solar TS-SB60(440) matched near 440.0 W STC and 41.18 V Voc, led by Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos1/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos2/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-440**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-440/) Elin Energy (Sirius PV) | 440.0 W | Tie (0 W) | 41.12 V | 20.47% | 94.2% |
| [**CertainTeed CTM10440HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/) CertainTeed | 440.0 W | Tie (0 W) | 41.02 V | 20.37% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB60(440)?

Evaluate Thornova Solar TS-SB60(440) (440.0 W STC, 41.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB60(440) reaches 45.57 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 438 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (438 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB60(440) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-SB60(440) 8 kW Residential Fit

Needs 19 modules (438 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 414.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-SB60(440) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Thornova Solar TS-SB60(440) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-SB60(440) cold Voc rises from 41.18 V to 44.6 V (beta_Voc -0.237%/C), capping a 600 V string at 13 panels (579.8 V).

### How much roof area does an 8 kW array of Thornova Solar TS-SB60(440) need?

An 8 kW DC system uses 19 Thornova Solar TS-SB60(440) modules (8,360 W STC / 7,881 W PTC), covering roughly 438 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

### How does Thornova Solar TS-SB60(440) compare against Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1?

Thornova Solar TS-SB60(440) outputs 440.0 W STC (41.18 V Voc, rank #6,418 of 21,677), while Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Thornova Solar equipment, Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-SB60(440).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)