---
title: "Thornova Solar TS-BGT78(620) Specs (620.0W, 55.99V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt78-620/
description: "CEC datasheet for Thornova Solar TS-BGT78(620): 620.0W STC, 55.99V Voc, 13-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-BGT78(620) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BGT78(620) is a 620.0 W STC (589.1 W PTC) Mono-c-Si solar module ranking #934 of 21,677 CEC listings (top 4.7%; higher than 95.3% of peers). It delivers 22.38% efficiency, 55.99 V Voc at 25 C, and 60.42 V cold Voc at -10 C (9 panels max per 600 V string).

- **STC Wattage** : 620.0 W

- **PTC Wattage** : 589.1 W

- **Voc @ 25C** : 55.99 V

- **Efficiency** : 22.38%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BGT78(620) Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-BGT78(620) handles rooftop heat (589.1 W PTC), 8 kW sizing, and cold winter string voltage.

Thornova Solar builds the Thornova Solar TS-BGT78(620) (Mono-c-Si) as a large-format commercial and ground-mount module delivering 223.8 W/m2 (2.47 percentage points above 19.91% CEC median). Compared against Philadelphia Solar PS-MNB156(HCBF)-620W (620.0 W), this model holds strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Higher 55.99 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), while NEC 690.8 sets a 21.43 A overcurrent floor served by a 25 A breaker.

## Where Does Thornova Solar TS-BGT78(620) Fall Across Listed CEC Models?

Where Thornova Solar TS-BGT78(620) (620.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-BGT78(620)?

Percentile placement of Thornova Solar TS-BGT78(620) across power density (223.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Thornova Solar TS-BGT78(620)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BGT78(620) specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #934 / 21,677

### Top 4.7% STC Output

620.0 W STC (+235.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,267

### 22.38% Aperture Efficiency

Power density 223.8 W/m2 (2.47 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.42 V at -10 C (543.8 V string) and 61.68 V at -20 C (9 max).

 8 kW Reference Array

### 13 Panels = 8,060 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,658 W PTC; NEC 690.8 OCPD floor is 21.43 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 55.99 * (1 + (-0.226/100) * (-10 - 25)) = 60.42 V | OCPD = 1.56 * 13.74 = 21.43 A

Inputs from CEC Modules.csv for Thornova Solar TS-BGT78(620): Voc=55.99 V, beta_Voc=-0.226%/C, Isc=13.74 A, STC=620.0 W, Area=2.77 m2.

**Result:** 9 panels max on 600 V (543.8 V); 13 panels for 8 kW (388 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BGT78(620)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BGT78(620).

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BGT78(620).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 620.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 589.1 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 55.99 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 47.44 V / 13.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.226 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.38% (2.77 m2) | Array roof footprint density |
| **Cell Count & Technology** | 78 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BGT78(620) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BGT78(620) (620.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.2 kW | 298 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 13 | 8.06 kW | 388 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 17 | 10.54 kW | 507 sq ft | $2,638 | $4,461 |

## How Many Thornova Solar TS-BGT78(620) Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-BGT78(620) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=55.99V and beta_Voc=-0.226%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 61.68 V | 9 panels | 555.1 V | 16 panels |
| **-10 C (14 F)** | 60.42 V | 9 panels | 543.8 V | 16 panels |
| **0 C (32 F)** | 59.15 V | 10 panels | 591.5 V | 16 panels |
| **25 C (77 F STC)** | 55.99 V | 10 panels | 559.9 V | 17 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT78(620)?

Alternative CEC solar modules from competing brands near Thornova Solar TS-BGT78(620) (620.0 W), including Philadelphia Solar PS-MNB156(HCBF)-620W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Philadelphia Solar PS-MNB156(HCBF)-620W**](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-620w/) Philadelphia Solar | 620.0 W | Tie (0 W) | 55.65 V | 22.22% | 94.3% |
| [**Heliene 156HC-615 M10 NTYP SL Bifacial**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-156hc-615-m10-ntyp-sl-bifacial/) Heliene | 615.0 W | -5.0 W | 56.92 V | 22.04% | 94.9% |
| [**Elin Energy (Sirius PV) ELNSM78M-HC-BF-610**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm78m-hc-bf-610/) Elin Energy (Sirius PV) | 610.0 W | -10.0 W | 54.63 V | 22.02% | 94.5% |
| [**Philadelphia Solar PS-MNB156(HCBF)-635W**](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-mnb156-hcbf-635w/) Philadelphia Solar | 635.0 W | +15.0 W | 56.1 V | 22.76% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT78(620)?

Evaluate Thornova Solar TS-BGT78(620) (620.0 W STC, 55.99 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT78(620) reaches 61.68 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT78(620) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BGT78(620) 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Philadelphia Solar PS-MNB156(HCBF)-620W.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 589.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BGT78(620) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT78(620)?

Multiplying Thornova Solar TS-BGT78(620)'s 13.74 A short-circuit current by 1.56 equals 21.43 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-BGT78(620) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 60.42 V cold Voc at 14 F and handles 13.74 A Isc; string inverters cap Thornova Solar TS-BGT78(620) at 9 panels on 600 V.

### Is Thornova Solar TS-BGT78(620) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT78(620) rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, Philadelphia Solar PS-MNB156(HCBF)-620W specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BGT78(620).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)
