title: "Thornova Solar TS-BGT66(600)-G12R Specs (600.0W, 48.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-600-g12r/
description: "CEC datasheet for Thornova Solar TS-BGT66(600)-G12R: 600.0W STC, 48.4V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-BGT66(600)-G12R — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BGT66(600)-G12R is a 600.0 W STC (569.8 W PTC) Mono-c-Si solar module ranking #1,320 of 21,677 CEC listings (top 6.7%; higher than 93.3% of peers). It delivers 22.39% efficiency, 48.4 V Voc at 25 C, and 51.87 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 600.0 W

- **PTC Wattage** : 569.8 W

- **Voc @ 25C** : 48.4 V

- **Efficiency** : 22.39%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BGT66(600)-G12R Compare Against Peer CEC Listings?

How Thornova Solar Thornova Solar TS-BGT66(600)-G12R handles rooftop heat (569.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Thornova Solar TS-BGT66(600)-G12R exhibits 15.8 A short-circuit current, requiring a 24.65 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,320 of 21,677 (190.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.5 m2 for an 8 kW system (17 panels for 10 kW). Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

## Where Does Thornova Solar TS-BGT66(600)-G12R Fall Across Listed CEC Models?

Where Thornova Solar TS-BGT66(600)-G12R (600.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-BGT66(600)-G12R?

Percentile placement of Thornova Solar TS-BGT66(600)-G12R across power density (223.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Thornova Solar TS-BGT66(600)-G12R?

Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-BGT66(600)-G12R specifications.

Rank #1,320 / 21,677

### Top 6.7% STC Output

600.0 W STC (+215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,254

### 22.39% Aperture Efficiency

Power density 223.9 W/m2 (2.48 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.87 V at -10 C (570.6 V string) and 52.86 V at -20 C (11 max).

 8 kW Reference Array

### 14 Panels = 8,400 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,977 W PTC; NEC 690.8 OCPD floor is 24.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.4 * (1 + (-0.205/100) * (-10 - 25)) = 51.87 V | OCPD = 1.56 * 15.8 = 24.65 A

Inputs from CEC Modules.csv for Thornova Solar TS-BGT66(600)-G12R: Voc=48.4 V, beta_Voc=-0.205%/C, Isc=15.8 A, STC=600.0 W, Area=2.68 m2.

**Result:** 11 panels max on 600 V (570.6 V); 14 panels for 8 kW (404 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BGT66(600)-G12R?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-BGT66(600)-G12R.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BGT66(600)-G12R.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 600.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 569.8 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 15.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.3 V / 14.91 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.205 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.39% (2.68 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BGT66(600)-G12R Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-BGT66(600)-G12R (600.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 10 | 6.0 kW | 288 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 14 | 8.4 kW | 404 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 17 | 10.2 kW | 490 sq ft | $2,553 | $4,317 |

## How Many Thornova Solar TS-BGT66(600)-G12R Modules Fit in a Cold-Weather String?

Maximum series module counts for Thornova Solar TS-BGT66(600)-G12R from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.4V and beta_Voc=-0.205%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.86 V | 11 panels | 581.5 V | 18 panels |
| **-10 C (14 F)** | 51.87 V | 11 panels | 570.6 V | 19 panels |
| **0 C (32 F)** | 50.88 V | 11 panels | 559.7 V | 19 panels |
| **25 C (77 F STC)** | 48.4 V | 12 panels | 580.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT66(600)-G12R?

Alternative CEC solar modules from competing brands near Thornova Solar TS-BGT66(600)-G12R (600.0 W), including Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm8611m-610r-h-hc-bf/) Boviet Solar Technology Co Ltd | 610.0 W | +10.0 W | 48.25 V | 24.21% | 95.3% |
| [**Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm8611m-610r-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 610.0 W | +10.0 W | 48.25 V | 24.21% | 95.3% |
| [**Jinko Solar Co Ltd JKM610N-66HL4M-BDV**](https://epri-peac.com/solar-equipment/modules/jinko-solar-co-ltd/jinko-solar-co-ltd-jkm610n-66hl4m-bdv/) Jinko Solar Co Ltd | 610.0 W | +10.0 W | 48.68 V | 22.59% | 94.2% |
| [**JA Solar JAM66D45-610/LB**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam66d45-610-lb/) JA Solar | 610.0 W | +10.0 W | 48.1 V | 23.11% | 93.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT66(600)-G12R?

Evaluate Thornova Solar TS-BGT66(600)-G12R (600.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT66(600)-G12R reaches 52.86 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT66(600)-G12R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BGT66(600)-G12R 8 kW Residential Fit

Needs 14 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 569.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BGT66(600)-G12R by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Thornova Solar TS-BGT66(600)-G12R PTC wattage (569.8 W) lower than STC (600.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 569.8 W PTC (95.0% retention) across Thornova Solar TS-BGT66(600)-G12R's 2.68 m2 aperture.

### Who should skip Thornova Solar TS-BGT66(600)-G12R on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Thornova Solar TS-BGT66(600)-G12R panels (404 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF.

### What is the 1,000 V commercial string limit for Thornova Solar TS-BGT66(600)-G12R?

On 1,000 V commercial inverters at -10 C (51.87 V cold Voc), Thornova Solar TS-BGT66(600)-G12R fits up to 19 panels per series string.

## Related Pages

Compare Thornova Solar equipment, Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BGT66(600)-G12R.

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)