Thornova Solar TS-BGT48(440)-G12R is a 440.0 W STC (418.2 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.0% efficiency, 34.67 V Voc at 25 C, and 38.01 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 418.2 W

- **Voc @ 25C** : 34.67 V

- **Efficiency** : 22.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BGT48(440)-G12R Compare Against Peer CEC Listings?

Solar engineering breakdown for Thornova Solar TS-BGT48(440)-G12R: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BGT48(440)-G12R stands 30.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Lower 34.67 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

## Where Does Thornova Solar TS-BGT48(440)-G12R Fall Across Listed CEC Models?

Distribution marker showing Thornova Solar TS-BGT48(440)-G12R (440.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Thornova Solar TS-BGT48(440)-G12R?

Dataset percentiles tracking Thornova Solar TS-BGT48(440)-G12R power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Thornova Solar TS-BGT48(440)-G12R?

Benchmark highlights for Thornova Solar TS-BGT48(440)-G12R covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,124

### 22.0% Aperture Efficiency

Power density 220.0 W/m2 (2.09 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 38.01 V at -10 C (570.1 V string) and 38.96 V at -20 C (15 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 38.0 m2 (409 sq ft) producing 7,946 W PTC; NEC 690.8 OCPD floor is 24.88 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 34.67 * (1 + (-0.275/100) * (-10 - 25)) = 38.01 V | OCPD = 1.56 * 15.95 = 24.88 A

Inputs from CEC Modules.csv for Thornova Solar TS-BGT48(440)-G12R: Voc=34.67 V, beta_Voc=-0.275%/C, Isc=15.95 A, STC=440.0 W, Area=2.0 m2.

**Result:** 15 panels max on 600 V (570.1 V); 19 panels for 8 kW (409 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BGT48(440)-G12R?

Official CEC datasheet figures for Thornova Solar TS-BGT48(440)-G12R (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BGT48(440)-G12R.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 418.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 34.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 15.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.72 V / 14.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.275 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.0% (2.0 m2) | Array roof footprint density |
| **Cell Count & Technology** | 48 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BGT48(440)-G12R Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Thornova Solar TS-BGT48(440)-G12R modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 301 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 409 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 495 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-BGT48(440)-G12R Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BGT48(440)-G12R (38.01 V at 14 F).

Computed from Voc=34.67V and beta_Voc=-0.275%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 38.96 V | 15 panels | 584.4 V | 25 panels |
| **-10 C (14 F)** | 38.01 V | 15 panels | 570.1 V | 26 panels |
| **0 C (32 F)** | 37.05 V | 16 panels | 592.8 V | 26 panels |
| **25 C (77 F STC)** | 34.67 V | 17 panels | 589.4 V | 28 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT48(440)-G12R?

Competing CEC solar panels closest to Thornova Solar TS-BGT48(440)-G12R in nameplate wattage and Voc, starting with CertainTeed CTTC435HC12-08.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CTTC435HC12-08**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc435hc12-08/) CertainTeed | 435.0 W | -5.0 W | 38.5 V | 22.31% | 94.8% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-BF-430**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-bf-430/) Elin Energy (Sirius PV) | 430.0 W | -10.0 W | 37.72 V | 22.16% | 94.5% |
| [**Aptos Solar Technology LLC DNA-108-BFN10-435W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bfn10-435w-dg/) Aptos Solar Technology LLC | 435.0 W | -5.0 W | 39.0 V | 22.42% | 94.9% |
| [**AMPS Solar AMPS-435N-108BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-435n-108bb/) AMPS Solar | 435.0 W | -5.0 W | 39.69 V | 22.42% | 95.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT48(440)-G12R?

Evaluate Thornova Solar TS-BGT48(440)-G12R (440.0 W STC, 34.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT48(440)-G12R reaches 38.96 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT48(440)-G12R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BGT48(440)-G12R 8 kW Residential Fit

Needs 19 modules (409 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare CertainTeed CTTC435HC12-08.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 418.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BGT48(440)-G12R by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT48(440)-G12R?

Multiplying Thornova Solar TS-BGT48(440)-G12R's 15.95 A short-circuit current by 1.56 equals 24.88 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-BGT48(440)-G12R pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 38.01 V cold Voc at 14 F and handles 15.95 A Isc; string inverters cap Thornova Solar TS-BGT48(440)-G12R at 15 panels on 600 V.

### Is Thornova Solar TS-BGT48(440)-G12R eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT48(440)-G12R rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, CertainTeed CTTC435HC12-08 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BGT48(440)-G12R.

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)