title: "Thornova Solar TS-BG60(460) Specs (460.0W, 41.78V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bg60-460/
description: "CEC datasheet for Thornova Solar TS-BG60(460): 460.0W STC, 41.78V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Thornova Solar TS-BG60(460) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BG60(460) is a 460.0 W STC (435.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.5% efficiency, 41.78 V Voc at 25 C, and 45.19 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 435.1 W

- **Voc @ 25C** : 41.78 V

- **Efficiency** : 21.5%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BG60(460) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Thornova Solar TS-BG60(460) (Mono-c-Si) residential solar systems.

Thornova Solar TS-BG60(460) delivers 215.0 W/m2 (1.59 percentage points above 19.91% CEC median) and strong 94.6% PTC-to-STC heat retention (#2,348 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 46.16 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W).

## Where Does Thornova Solar TS-BG60(460) Fall Across Listed CEC Models?

Comparison of Thornova Solar TS-BG60(460) (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Thornova Solar TS-BG60(460)?

Relative ranking of Thornova Solar TS-BG60(460) across nameplate watts, 94.6% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Thornova Solar TS-BG60(460)?

Summary of Thornova Solar TS-BG60(460) output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,451

### 21.5% Aperture Efficiency

Power density 215.0 W/m2 (1.59 percentage points above 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.19 V at -10 C (587.5 V string) and 46.16 V at -20 C (12 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,832 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.78 * (1 + (-0.233/100) * (-10 - 25)) = 45.19 V | OCPD = 1.56 * 13.63 = 21.26 A

Inputs from CEC Modules.csv for Thornova Solar TS-BG60(460): Voc=41.78 V, beta_Voc=-0.233%/C, Isc=13.63 A, STC=460.0 W, Area=2.14 m2.

**Result:** 13 panels max on 600 V (587.5 V); 18 panels for 8 kW (415 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BG60(460)?

Complete CEC test sheet for Thornova Solar TS-BG60(460) including Isc (13.63 A), Voc (41.78 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BG60(460).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 435.1 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.78 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.89 V / 13.19 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.233 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.5% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BG60(460) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Thornova Solar TS-BG60(460).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 322 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 415 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 507 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-BG60(460) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Thornova Solar TS-BG60(460) (41.78 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.78V and beta_Voc=-0.233%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.16 V | 12 panels | 553.9 V | 21 panels |
| **-10 C (14 F)** | 45.19 V | 13 panels | 587.5 V | 22 panels |
| **0 C (32 F)** | 44.21 V | 13 panels | 574.7 V | 22 panels |
| **25 C (77 F STC)** | 41.78 V | 14 panels | 584.9 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BG60(460)?

Four comparable CEC modules such as Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 (460.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Elin Energy (Sirius PV) ELNSM60M-HC-BF-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-bf-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.4% |
| [**Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-460-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 460.0 W | Tie (0 W) | 42.49 V | 21.9% | 94.2% |
| [**Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-455w-usaptos2/) Aptos Solar Technology LLC | 455.0 W | -5.0 W | 41.7 V | 21.26% | 94.4% |
| [**Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-455w-usaptos1/) Aptos Solar Technology LLC | 455.0 W | -5.0 W | 41.65 V | 21.26% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BG60(460)?

Evaluate Thornova Solar TS-BG60(460) (460.0 W STC, 41.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BG60(460) reaches 46.16 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BG60(460) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BG60(460) 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM60M-HC-BF-460.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 435.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BG60(460) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Thornova Solar TS-BG60(460) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-BG60(460) cold Voc rises from 41.78 V to 45.19 V (beta_Voc -0.233%/C), capping a 600 V string at 13 panels (587.5 V).

### How much roof area does an 8 kW array of Thornova Solar TS-BG60(460) need?

An 8 kW DC system uses 18 Thornova Solar TS-BG60(460) modules (8,280 W STC / 7,832 W PTC), covering roughly 415 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

### How does Thornova Solar TS-BG60(460) compare against Elin Energy (Sirius PV) ELNSM60M-HC-BF-460?

Thornova Solar TS-BG60(460) outputs 460.0 W STC (41.78 V Voc, rank #5,199 of 21,677), while Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Thornova Solar equipment, Elin Energy (Sirius PV) ELNSM60M-HC-BF-460 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BG60(460).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)