title: "Thornova Solar TS-BBT54(420) Specs (420.0W, 38.51V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bbt54-420/
description: "CEC datasheet for Thornova Solar TS-BBT54(420): 420.0W STC, 38.51V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Thornova Solar TS-BBT54(420) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BBT54(420) is a 420.0 W STC (398.4 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.65% efficiency, 38.51 V Voc at 25 C, and 41.54 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 398.4 W

- **Voc @ 25C** : 38.51 V

- **Efficiency** : 21.65%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BBT54(420) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BBT54(420) (420.0 W STC) vs. Aptos Solar Technology LLC DNA-108-BFN10-420W-DG across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Thornova Solar TS-BBT54(420) pairs strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677) with 38.51 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,968 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Aptos Solar Technology LLC DNA-108-BFN10-420W-DG offers a 420.0 W alternative.

## Where Does Thornova Solar TS-BBT54(420) Fall Across Listed CEC Models?

Plots Thornova Solar TS-BBT54(420) at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-BBT54(420)?

Benchmarks Thornova Solar TS-BBT54(420) on STC wattage, thermal PTC/STC retention, and 21.65 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Thornova Solar TS-BBT54(420)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BBT54(420) by Thornova Solar.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,009

### 21.65% Aperture Efficiency

Power density 216.5 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.54 V at -10 C (581.6 V string) and 42.41 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,968 W PTC; NEC 690.8 OCPD floor is 20.9 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.51 * (1 + (-0.225/100) * (-10 - 25)) = 41.54 V | OCPD = 1.56 * 13.4 = 20.9 A

Inputs from CEC Modules.csv for Thornova Solar TS-BBT54(420): Voc=38.51 V, beta_Voc=-0.225%/C, Isc=13.4 A, STC=420.0 W, Area=1.94 m2.

**Result:** 14 panels max on 600 V (581.6 V); 20 panels for 8 kW (418 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BBT54(420)?

Laboratory test ratings recorded for Thornova Solar TS-BBT54(420) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BBT54(420).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 398.4 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.51 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.92 V / 12.76 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.225 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.65% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BBT54(420) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BBT54(420).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 313 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 418 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 501 sq ft | $2,523 | $4,266 |

## How Many Thornova Solar TS-BBT54(420) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BBT54(420) (beta_Voc -0.225%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.51V and beta_Voc=-0.225%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.41 V | 14 panels | 593.7 V | 23 panels |
| **-10 C (14 F)** | 41.54 V | 14 panels | 581.6 V | 24 panels |
| **0 C (32 F)** | 40.68 V | 14 panels | 569.5 V | 24 panels |
| **25 C (77 F STC)** | 38.51 V | 15 panels | 577.6 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BBT54(420)?

Closest cross-brand CEC competitors to Thornova Solar TS-BBT54(420) matched near 420.0 W STC and 38.51 V Voc, led by Aptos Solar Technology LLC DNA-108-BFN10-420W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-BFN10-420W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bfn10-420w-dg/) Aptos Solar Technology LLC | 420.0 W | Tie (0 W) | 37.6 V | 21.65% | 94.9% |
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc-bf/) Boviet Solar Technology Co Ltd | 415.0 W | -5.0 W | 38.47 V | 19.21% | 94.7% |
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 415.0 W | -5.0 W | 38.47 V | 19.21% | 94.7% |
| [**CSI Solar Co Ltd CS6R-410MB**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb/) CSI Solar Co Ltd | 410.0 W | -10.0 W | 38.0 V | 21.69% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BBT54(420)?

Evaluate Thornova Solar TS-BBT54(420) (420.0 W STC, 38.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BBT54(420) reaches 42.41 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BBT54(420) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BBT54(420) 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BFN10-420W-DG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 398.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BBT54(420) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BBT54(420)?

Multiplying Thornova Solar TS-BBT54(420)'s 13.4 A short-circuit current by 1.56 equals 20.9 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-BBT54(420) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.54 V cold Voc at 14 F and handles 13.4 A Isc; string inverters cap Thornova Solar TS-BBT54(420) at 14 panels on 600 V.

### Is Thornova Solar TS-BBT54(420) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BBT54(420) rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, Aptos Solar Technology LLC DNA-108-BFN10-420W-DG specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BBT54(420).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)