title: "Thornova Solar TS-BB72(550) Specs (550.0W, 49.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bb72-550/
description: "CEC datasheet for Thornova Solar TS-BB72(550): 550.0W STC, 49.6V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Thornova Solar TS-BB72(550) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BB72(550) is a 550.0 W STC (512.7 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.32% efficiency, 49.6 V Voc at 25 C, and 54.15 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 550.0 W

- **PTC Wattage** : 512.7 W

- **Voc @ 25C** : 49.6 V

- **Efficiency** : 21.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BB72(550) Compare Against Peer CEC Listings?

Engineering position of Thornova Solar TS-BB72(550) (550.0 W STC) vs. Energate Energy Inc EG-144L550W across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Thornova Solar TS-BB72(550) pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 49.6 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,690 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Energate Energy Inc EG-144L550W offers a 550.0 W alternative.

## Where Does Thornova Solar TS-BB72(550) Fall Across Listed CEC Models?

Plots Thornova Solar TS-BB72(550) at 550.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Thornova Solar TS-BB72(550)?

Benchmarks Thornova Solar TS-BB72(550) on STC wattage, thermal PTC/STC retention, and 21.32 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Thornova Solar TS-BB72(550)?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Thornova Solar TS-BB72(550) by Thornova Solar.

Rank #2,737 / 21,677

### Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,973

### 21.32% Aperture Efficiency

Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.15 V at -10 C (595.6 V string) and 55.45 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,250 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,690 W PTC; NEC 690.8 OCPD floor is 21.9 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.262/100) * (-10 - 25)) = 54.15 V | OCPD = 1.56 * 14.04 = 21.9 A

Inputs from CEC Modules.csv for Thornova Solar TS-BB72(550): Voc=49.6 V, beta_Voc=-0.262%/C, Isc=14.04 A, STC=550.0 W, Area=2.58 m2.

**Result:** 11 panels max on 600 V (595.6 V); 15 panels for 8 kW (417 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BB72(550)?

Laboratory test ratings recorded for Thornova Solar TS-BB72(550) (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BB72(550).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 512.7 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.83 V / 13.48 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.262 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.32% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Thornova Solar TS-BB72(550) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (417 sq ft at 8 kW), and estimated Year-1 electric bill offset for Thornova Solar TS-BB72(550).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.05 kW | 305 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 15 | 8.25 kW | 417 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 19 | 10.45 kW | 528 sq ft | $2,616 | $4,423 |

## How Many Thornova Solar TS-BB72(550) Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Thornova Solar TS-BB72(550) (beta_Voc -0.262%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.6V and beta_Voc=-0.262%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 55.45 V | 10 panels | 554.5 V | 18 panels |
| **-10 C (14 F)** | 54.15 V | 11 panels | 595.6 V | 18 panels |
| **0 C (32 F)** | 52.85 V | 11 panels | 581.4 V | 18 panels |
| **25 C (77 F STC)** | 49.6 V | 12 panels | 595.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB72(550)?

Closest cross-brand CEC competitors to Thornova Solar TS-BB72(550) matched near 550.0 W STC and 49.6 V Voc, led by Energate Energy Inc EG-144L550W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Energate Energy Inc EG-144L550W**](https://epri-peac.com/solar-equipment/modules/energate-energy-inc/energate-energy-inc-eg-144l550w/) Energate Energy Inc | 550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
| [**Energate Enerji retim San A EG-144L550W**](https://epri-peac.com/solar-equipment/modules/energate-enerji-retim-san-a/energate-enerji-retim-san-a-eg-144l550w/) Energate Enerji retim San A | 550.0 W | Tie (0 W) | 49.62 V | 21.48% | 93.8% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M172B 550W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m172b-550w/) Dehui Solar Power (Vietnam) CoLtd | 550.0 W | Tie (0 W) | 49.77 V | 21.48% | 93.5% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M172W 550W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m172w-550w/) Dehui Solar Power (Vietnam) CoLtd | 550.0 W | Tie (0 W) | 49.77 V | 21.48% | 93.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB72(550)?

Evaluate Thornova Solar TS-BB72(550) (550.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB72(550) reaches 55.45 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB72(550) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BB72(550) 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Energate Energy Inc EG-144L550W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 512.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BB72(550) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB72(550)?

Multiplying Thornova Solar TS-BB72(550)'s 14.04 A short-circuit current by 1.56 equals 21.9 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-BB72(550) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.15 V cold Voc at 14 F and handles 14.04 A Isc; string inverters cap Thornova Solar TS-BB72(550) at 11 panels on 600 V.

### Is Thornova Solar TS-BB72(550) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB72(550) rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, Energate Energy Inc EG-144L550W specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BB72(550).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)