title: "Thornova Solar TS-BB60(440) Specs (440.0W, 41.18V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bb60-440/
description: "CEC datasheet for Thornova Solar TS-BB60(440): 440.0W STC, 41.18V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Thornova Solar TS-BB60(440) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BB60(440) is a 440.0 W STC (415.1 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.56% efficiency, 41.18 V Voc at 25 C, and 44.52 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 415.1 W

- **Voc @ 25C** : 41.18 V

- **Efficiency** : 20.56%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BB60(440) Compare Against Peer CEC Listings?

Solar engineering breakdown for Thornova Solar TS-BB60(440): PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BB60(440) stands 30.0 W above the 410.0 W Mono-c-Si median and strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Mid-range 41.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does Thornova Solar TS-BB60(440) Fall Across Listed CEC Models?

Distribution marker showing Thornova Solar TS-BB60(440) (440.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Thornova Solar TS-BB60(440)?

Dataset percentiles tracking Thornova Solar TS-BB60(440) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Thornova Solar TS-BB60(440)?

Benchmark highlights for Thornova Solar TS-BB60(440) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,260

### 20.56% Aperture Efficiency

Power density 205.6 W/m2 (0.65 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.52 V at -10 C (578.8 V string) and 45.48 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 40.7 m2 (438 sq ft) producing 7,887 W PTC; NEC 690.8 OCPD floor is 20.86 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.18 * (1 + (-0.232/100) * (-10 - 25)) = 44.52 V | OCPD = 1.56 * 13.37 = 20.86 A

Inputs from CEC Modules.csv for Thornova Solar TS-BB60(440): Voc=41.18 V, beta_Voc=-0.232%/C, Isc=13.37 A, STC=440.0 W, Area=2.14 m2.

**Result:** 13 panels max on 600 V (578.8 V); 19 panels for 8 kW (438 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BB60(440)?

Official CEC datasheet figures for Thornova Solar TS-BB60(440) (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BB60(440).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 415.1 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.33 V / 12.82 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.232 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.56% (2.14 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BB60(440) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Thornova Solar TS-BB60(440) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 322 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 438 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 530 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-BB60(440) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BB60(440) (44.52 V at 14 F).

Computed from Voc=41.18V and beta_Voc=-0.232%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.48 V | 13 panels | 591.2 V | 21 panels |
| **-10 C (14 F)** | 44.52 V | 13 panels | 578.8 V | 22 panels |
| **0 C (32 F)** | 43.57 V | 13 panels | 566.4 V | 22 panels |
| **25 C (77 F STC)** | 41.18 V | 14 panels | 576.5 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB60(440)?

Competing CEC solar panels closest to Thornova Solar TS-BB60(440) in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-440w-usaptos1/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-440w-usaptos2/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.2 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-BF10-440W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bf10-440w/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M160T 440W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m160t-440w/) Dehui Solar Power (Vietnam) CoLtd | 440.0 W | Tie (0 W) | 41.11 V | 20.56% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB60(440)?

Evaluate Thornova Solar TS-BB60(440) (440.0 W STC, 41.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB60(440) reaches 45.48 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 438 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (438 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB60(440) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BB60(440) 8 kW Residential Fit

Needs 19 modules (438 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 415.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BB60(440) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BB60(440)?

Multiplying Thornova Solar TS-BB60(440)'s 13.37 A short-circuit current by 1.56 equals 20.86 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Thornova Solar TS-BB60(440) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.52 V cold Voc at 14 F and handles 13.37 A Isc; string inverters cap Thornova Solar TS-BB60(440) at 13 panels on 600 V.

### Is Thornova Solar TS-BB60(440) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BB60(440) rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare Thornova Solar equipment, Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BB60(440).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)