title: "Thornova Solar TS-BB54(405) Specs (405.0W, 37.3V Voc)"
url: https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bb54-405/
description: "CEC datasheet for Thornova Solar TS-BB54(405): 405.0W STC, 37.3V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Thornova Solar TS-BB54(405) — CEC Solar Module Specifications

Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BB54(405) is a 405.0 W STC (376.9 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.77% efficiency, 37.3 V Voc at 25 C, and 40.69 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 405.0 W

- **PTC Wattage** : 376.9 W

- **Voc @ 25C** : 37.3 V

- **Efficiency** : 20.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BB54(405) Compare Against Peer CEC Listings?

Solar engineering breakdown for Thornova Solar TS-BB54(405): PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 405.0 W STC and 376.9 W PTC, Thornova Solar TS-BB54(405) sits +20.0 W vs all-CEC median (top 43.4%; higher than 56.6% of peers) among 21,677 listed modules. Power density reaches 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). Lower 37.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Belinus Solar BV BE-M7-GG-108-405 rates 405.0 W.

## Where Does Thornova Solar TS-BB54(405) Fall Across Listed CEC Models?

Distribution marker showing Thornova Solar TS-BB54(405) (405.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Thornova Solar TS-BB54(405)?

Dataset percentiles tracking Thornova Solar TS-BB54(405) power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Thornova Solar TS-BB54(405)?

Benchmark highlights for Thornova Solar TS-BB54(405) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,961 / 21,677

### Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

### 20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.69 V at -10 C (569.7 V string) and 41.66 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,100 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,538 W PTC; NEC 690.8 OCPD floor is 20.97 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.3 * (1 + (-0.26/100) * (-10 - 25)) = 40.69 V | OCPD = 1.56 * 13.44 = 20.97 A

Inputs from CEC Modules.csv for Thornova Solar TS-BB54(405): Voc=37.3 V, beta_Voc=-0.26%/C, Isc=13.44 A, STC=405.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (569.7 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BB54(405)?

Official CEC datasheet figures for Thornova Solar TS-BB54(405) (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BB54(405).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 376.9 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.6 V / 12.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.26 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.77% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BB54(405) Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Thornova Solar TS-BB54(405) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.08 kW | 315 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 20 | 8.1 kW | 420 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 25 | 10.12 kW | 525 sq ft | $2,533 | $4,283 |

## How Many Thornova Solar TS-BB54(405) Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BB54(405) (40.69 V at 14 F).

Computed from Voc=37.3V and beta_Voc=-0.26%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.66 V | 14 panels | 583.2 V | 24 panels |
| **-10 C (14 F)** | 40.69 V | 14 panels | 569.7 V | 24 panels |
| **0 C (32 F)** | 39.72 V | 15 panels | 595.8 V | 25 panels |
| **25 C (77 F STC)** | 37.3 V | 16 panels | 596.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB54(405)?

Competing CEC solar panels closest to Thornova Solar TS-BB54(405) in nameplate wattage and Voc, starting with Belinus Solar BV BE-M7-GG-108-405.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Belinus Solar BV BE-M7-GG-108-405**](https://epri-peac.com/solar-equipment/modules/belinus-solar-bv/belinus-solar-bv-be-m7-gg-108-405/) Belinus Solar BV | 405.0 W | Tie (0 W) | 37.36 V | 20.77% | 93.8% |
| [**Aptos Solar Technology LLC DNA-108-BF10-405W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bf10-405w/) Aptos Solar Technology LLC | 405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m154t-405w/) Dehui Solar Power (Vietnam) CoLtd | 405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae405md-108bs/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB54(405)?

Evaluate Thornova Solar TS-BB54(405) (405.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB54(405) reaches 41.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB54(405) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BB54(405) 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Belinus Solar BV BE-M7-GG-108-405.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 376.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BB54(405) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Thornova Solar TS-BB54(405) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-BB54(405) cold Voc rises from 37.3 V to 40.69 V (beta_Voc -0.26%/C), capping a 600 V string at 14 panels (569.7 V).

### How much roof area does an 8 kW array of Thornova Solar TS-BB54(405) need?

An 8 kW DC system uses 20 Thornova Solar TS-BB54(405) modules (8,100 W STC / 7,538 W PTC), covering roughly 420 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Thornova Solar TS-BB54(405) compare against Belinus Solar BV BE-M7-GG-108-405?

Thornova Solar TS-BB54(405) outputs 405.0 W STC (37.3 V Voc, rank #8,961 of 21,677), while Belinus Solar BV BE-M7-GG-108-405 delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Thornova Solar equipment, Belinus Solar BV BE-M7-GG-108-405 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BB54(405).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)