Manufacturer: [**Thornova Solar**](https://epri-peac.com/solar-equipment/brands/thornova-solar/) Registry: **CEC Verified Engineering Specification**

Thornova Solar TS-BB54(400) is a 400.0 W STC (372.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.51% efficiency, 37.2 V Voc at 25 C, and 40.59 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 400.0 W

- **PTC Wattage** : 372.2 W

- **Voc @ 25C** : 37.2 V

- **Efficiency** : 20.51%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Thornova Solar TS-BB54(400) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Thornova Solar TS-BB54(400) (Mono-c-Si) residential solar systems.

Thornova Solar TS-BB54(400) delivers 205.1 W/m2 (0.60 percentage points above 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.55 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with CertainTeed CTM10400HC11-08 (400.0 W).

## Where Does Thornova Solar TS-BB54(400) Fall Across Listed CEC Models?

Comparison of Thornova Solar TS-BB54(400) (400.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Thornova Solar TS-BB54(400)?

Relative ranking of Thornova Solar TS-BB54(400) across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Thornova Solar TS-BB54(400)?

Summary of Thornova Solar TS-BB54(400) output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #9,407 / 21,677

### Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

### 20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.59 V at -10 C (568.3 V string) and 41.55 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,000 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,444 W PTC; NEC 690.8 OCPD floor is 20.89 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.2 * (1 + (-0.26/100) * (-10 - 25)) = 40.59 V | OCPD = 1.56 * 13.39 = 20.89 A

Inputs from CEC Modules.csv for Thornova Solar TS-BB54(400): Voc=37.2 V, beta_Voc=-0.26%/C, Isc=13.39 A, STC=400.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (568.3 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for Thornova Solar TS-BB54(400)?

Complete CEC test sheet for Thornova Solar TS-BB54(400) including Isc (13.39 A), Voc (37.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Thornova Solar TS-BB54(400).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 372.2 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.4 V / 12.74 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.26 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.51% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Thornova Solar TS-BB54(400) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Thornova Solar TS-BB54(400).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.0 kW | 315 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 20 | 8.0 kW | 420 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 25 | 10.0 kW | 525 sq ft | $2,503 | $4,232 |

## How Many Thornova Solar TS-BB54(400) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Thornova Solar TS-BB54(400) (37.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.2V and beta_Voc=-0.26%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.55 V | 14 panels | 581.7 V | 24 panels |
| **-10 C (14 F)** | 40.59 V | 14 panels | 568.3 V | 24 panels |
| **0 C (32 F)** | 39.62 V | 15 panels | 594.3 V | 25 panels |
| **25 C (77 F STC)** | 37.2 V | 16 panels | 595.2 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BB54(400)?

Four comparable CEC modules such as CertainTeed CTM10400HC11-08 (400.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CTM10400HC11-08**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10400hc11-08/) CertainTeed | 400.0 W | Tie (0 W) | 37.08 V | 20.73% | 94.1% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae405md-108bs/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 405.0 W | +5.0 W | 37.2 V | 20.98% | 93.4% |
| [**AXITEC AC-405MBT/108V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-405mbt-108v/) AXITEC | 405.0 W | +5.0 W | 37.2 V | 20.98% | 93.4% |
| [**Aptos Solar Technology LLC DNA-108-BF10-405W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bf10-405w/) Aptos Solar Technology LLC | 405.0 W | +5.0 W | 37.23 V | 20.98% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BB54(400)?

Evaluate Thornova Solar TS-BB54(400) (400.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BB54(400) reaches 41.55 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BB54(400) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Thornova Solar TS-BB54(400) 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10400HC11-08.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 372.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Thornova Solar TS-BB54(400) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Thornova Solar TS-BB54(400) panels fit on a 600 V winter solar string?

At -10 C (14 F), Thornova Solar TS-BB54(400) cold Voc rises from 37.2 V to 40.59 V (beta_Voc -0.26%/C), capping a 600 V string at 14 panels (568.3 V).

### How much roof area does an 8 kW array of Thornova Solar TS-BB54(400) need?

An 8 kW DC system uses 20 Thornova Solar TS-BB54(400) modules (8,000 W STC / 7,444 W PTC), covering roughly 420 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does Thornova Solar TS-BB54(400) compare against CertainTeed CTM10400HC11-08?

Thornova Solar TS-BB54(400) outputs 400.0 W STC (37.2 V Voc, rank #9,407 of 21,677), while CertainTeed CTM10400HC11-08 delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Thornova Solar equipment, CertainTeed CTM10400HC11-08 specs, utility payback rates, and NEC string calculators alongside Thornova Solar TS-BB54(400).

[All Thornova Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/thornova-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Thornova Solar

- [All Thornova Solar Specs](https://epri-peac.com/solar-equipment/brands/thornova-solar/)
- [Thornova Solar TS-BGT66(730)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-730-g12/)
- [Thornova Solar TS-BGT66(725)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-725-g12/)
- [Thornova Solar TS-BGT66(720)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-720-g12/)
- [Thornova Solar TS-BGT66(715)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-715-g12/)
- [Thornova Solar TS-BGT66(710)-G12](https://epri-peac.com/solar-equipment/modules/thornova-solar/thornova-solar-ts-bgt66-710-g12/)