title: "Tesla Inc T420S Specs (420.0W, 48.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/
description: "CEC datasheet for Tesla Inc T420S: 420.0W STC, 48.5V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Tesla Inc T420S — CEC Solar Module Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc T420S is a 420.0 W STC (392.2 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.9% efficiency, 48.5 V Voc at 25 C, and 52.91 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 420.0 W

- **PTC Wattage** : 392.2 W

- **Voc @ 25C** : 48.5 V

- **Efficiency** : 19.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc T420S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Tesla Inc T420S (Mono-c-Si) residential solar systems.

Homeowners evaluating Tesla Inc T420S need 15 panels for 6 kW or 20 panels (454 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (454 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.26%/C) pushes open-circuit voltage to 52.91 V at 14 F and 54.17 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Tesla Inc T420S Fall Across Listed CEC Models?

Comparison of Tesla Inc T420S (420.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Tesla Inc T420S?

Relative ranking of Tesla Inc T420S across nameplate watts, 93.4% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Tesla Inc T420S?

Summary of Tesla Inc T420S output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #7,910 / 21,677

### Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,850

### 19.9% Aperture Efficiency

Power density 199.0 W/m2 (0.01 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.91 V at -10 C (582.0 V string) and 54.17 V at -20 C (11 max).

 8 kW Reference Array

### 20 Panels = 8,400 W STC

Occupies 42.2 m2 (454 sq ft) producing 7,844 W PTC; NEC 690.8 OCPD floor is 17.41 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.5 * (1 + (-0.26/100) * (-10 - 25)) = 52.91 V | OCPD = 1.56 * 11.16 = 17.41 A

Inputs from CEC Modules.csv for Tesla Inc T420S: Voc=48.5 V, beta_Voc=-0.26%/C, Isc=11.16 A, STC=420.0 W, Area=2.111 m2.

**Result:** 11 panels max on 600 V (582.0 V); 20 panels for 8 kW (454 sq ft).

## What Are the Published CEC Specifications for Tesla Inc T420S?

Complete CEC test sheet for Tesla Inc T420S including Isc (11.16 A), Voc (48.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc T420S.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 392.2 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.9 V / 10.27 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.26 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.9% (2.111 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Tesla Inc T420S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Tesla Inc T420S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.3 kW | 341 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 20 | 8.4 kW | 454 sq ft | $2,102 | $3,555 |
| **10 kW Class** | 24 | 10.08 kW | 545 sq ft | $2,523 | $4,266 |

## How Many Tesla Inc T420S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Tesla Inc T420S (48.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.5V and beta_Voc=-0.26%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.17 V | 11 panels | 595.9 V | 18 panels |
| **-10 C (14 F)** | 52.91 V | 11 panels | 582.0 V | 18 panels |
| **0 C (32 F)** | 51.65 V | 11 panels | 568.1 V | 19 panels |
| **25 C (77 F STC)** | 48.5 V | 12 panels | 582.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Tesla Inc T420S?

Four comparable CEC modules such as DualSun SAS DualSun 420M-144-01 (420.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DualSun SAS DualSun 420M-144-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-420m-144-01/) DualSun SAS | 420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| [**AXITEC AC-410MH/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mh-144v/) AXITEC | 410.0 W | -10.0 W | 48.91 V | 20.71% | 93.5% |
| [**BYD Company Limited BYD400MIK-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd400mik-36/) BYD Company Limited | 410.0 W | -10.0 W | 49.21 V | 20.4% | 94.0% |
| [**AXITEC AC-410MB/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-410mb-144v/) AXITEC | 410.0 W | -10.0 W | 49.3 V | 21.03% | 93.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc T420S?

Evaluate Tesla Inc T420S (420.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc T420S reaches 54.17 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 454 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (454 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Tesla Inc T420S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Tesla Inc T420S 8 kW Residential Fit

Needs 20 modules (454 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 392.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc T420S by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Tesla Inc T420S PTC wattage (392.2 W) lower than STC (420.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 392.2 W PTC (93.4% retention) across Tesla Inc T420S's 2.111 m2 aperture.

### Who should skip Tesla Inc T420S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Tesla Inc T420S panels (454 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 420M-144-01.

### What is the 1,000 V commercial string limit for Tesla Inc T420S?

On 1,000 V commercial inverters at -10 C (52.91 V cold Voc), Tesla Inc T420S fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc T420S.

## Related Pages

Compare Tesla Inc equipment, DualSun SAS DualSun 420M-144-01 specs, utility payback rates, and NEC string calculators alongside Tesla Inc T420S.

[All Tesla Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc T430S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/)
- [Tesla Inc TSP-430](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/)
- [Tesla Inc TSP-415](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/)
- [Tesla Inc T400H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/)
- [Tesla Inc T395H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t395h/)