title: "Tesla Inc SR86T3R Specs (86.0W, 26.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr86t3r/
description: "CEC datasheet for Tesla Inc SR86T3R: 86.0W STC, 26.6V Voc, 94-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Tesla Inc SR86T3R — CEC Solar Module Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc SR86T3R is a 86.0 W STC (77.3 W PTC) Mono-c-Si solar module ranking #21,601 of 21,677 CEC listings (below all-CEC median; higher than 0.4% of peers). It delivers 17.92% efficiency, 26.6 V Voc at 25 C, and 29.03 V cold Voc at -10 C (20 panels max per 600 V string).

- **STC Wattage** : 86.0 W

- **PTC Wattage** : 77.3 W

- **Voc @ 25C** : 26.6 V

- **Efficiency** : 17.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc SR86T3R Compare Against Peer CEC Listings?

How Tesla Inc Tesla Inc SR86T3R handles rooftop heat (77.3 W PTC), 8 kW sizing, and cold winter string voltage.

Tesla Inc builds the Tesla Inc SR86T3R (Mono-c-Si) as a compact residential or specialty off-grid module delivering 179.2 W/m2 (1.99 percentage points below 19.91% CEC median). Compared against Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85 (85.0 W), this model holds typical 89.9% PTC-to-STC thermal output (77.3 W real-world rating). Lower 26.6 V string voltage fits 20 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 6.33 A overcurrent floor served by a 15 A breaker.

## Where Does Tesla Inc SR86T3R Fall Across Listed CEC Models?

Where Tesla Inc SR86T3R (86.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Tesla Inc SR86T3R?

Percentile placement of Tesla Inc SR86T3R across power density (179.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Tesla Inc SR86T3R?

Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR86T3R specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #21,601 / 21,677

### 86.0 W STC · Higher Than 0.4%

86.0 W STC (-299.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,210

### 17.92% Aperture Efficiency

Power density 179.2 W/m2 (1.99 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

### 20 Panels Max @ -10 C (600 V)

Cold Voc reaches 29.03 V at -10 C (580.6 V string) and 29.72 V at -20 C (20 max).

 8 kW Reference Array

### 94 Panels = 8,084 W STC

Occupies 45.1 m2 (486 sq ft) producing 7,266 W PTC; NEC 690.8 OCPD floor is 6.33 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 26.6 * (1 + (-0.261/100) * (-10 - 25)) = 29.03 V | OCPD = 1.56 * 4.06 = 6.33 A

Inputs from CEC Modules.csv for Tesla Inc SR86T3R: Voc=26.6 V, beta_Voc=-0.261%/C, Isc=4.06 A, STC=86.0 W, Area=0.48 m2.

**Result:** 20 panels max on 600 V (580.6 V); 94 panels for 8 kW (486 sq ft).

## What Are the Published CEC Specifications for Tesla Inc SR86T3R?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR86T3R.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR86T3R.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 86.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 77.3 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 26.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 4.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 22.51 V / 3.79 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.261 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.92% (0.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 39 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Tesla Inc SR86T3R Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR86T3R (86.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 70 | 6.02 kW | 362 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 94 | 8.08 kW | 486 sq ft | $2,022 | $3,420 |
| **10 kW Class** | 117 | 10.06 kW | 605 sq ft | $2,518 | $4,258 |

## How Many Tesla Inc SR86T3R Modules Fit in a Cold-Weather String?

Maximum series module counts for Tesla Inc SR86T3R from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=26.6V and beta_Voc=-0.261%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 29.72 V | 20 panels | 594.4 V | 33 panels |
| **-10 C (14 F)** | 29.03 V | 20 panels | 580.6 V | 34 panels |
| **0 C (32 F)** | 28.34 V | 21 panels | 595.1 V | 35 panels |
| **25 C (77 F STC)** | 26.6 V | 22 panels | 585.2 V | 37 panels |

## Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR86T3R?

Alternative CEC solar modules from competing brands near Tesla Inc SR86T3R (86.0 W), including Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85**](https://epri-peac.com/solar-equipment/modules/jinzhou-jinmao-photovoltaic-technology/jinzhou-jinmao-photovoltaic-technology-jmpv-5m-36-85/) Jinzhou Jinmao Photovoltaic Technology | 85.0 W | -1.0 W | 22.0 V | 12.8% | 87.2% |
| [**Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-90**](https://epri-peac.com/solar-equipment/modules/jinzhou-jinmao-photovoltaic-technology/jinzhou-jinmao-photovoltaic-technology-jmpv-5m-36-90/) Jinzhou Jinmao Photovoltaic Technology | 90.0 W | +4.0 W | 22.2 V | 13.55% | 87.3% |
| [**Philadelphia Solar PS-M36S-95**](https://epri-peac.com/solar-equipment/modules/philadelphia-solar/philadelphia-solar-ps-m36s-95/) Philadelphia Solar | 95.0 W | +9.0 W | 22.4 V | 14.35% | 88.4% |
| [**Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-95**](https://epri-peac.com/solar-equipment/modules/jinzhou-jinmao-photovoltaic-technology/jinzhou-jinmao-photovoltaic-technology-jmpv-5m-36-95/) Jinzhou Jinmao Photovoltaic Technology | 95.0 W | +9.0 W | 22.39 V | 14.3% | 87.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc SR86T3R?

Evaluate Tesla Inc SR86T3R (86.0 W STC, 26.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR86T3R reaches 29.72 V per panel—exceeding 20 panels in series voids 600 V inverter warranties.
- Footprint constraint: 94 panels for an 8 kW build require 486 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 94 panels (486 sq ft).
- 2026 tax credit baseline: cash residential installs of Tesla Inc SR86T3R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Tesla Inc SR86T3R 8 kW Residential Fit

Needs 94 modules (486 sq ft) with a 15 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 20 panels (-10 C) or 20 panels (-20 C), or compare Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 77.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR86T3R by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Tesla Inc SR86T3R?

Multiplying Tesla Inc SR86T3R's 4.06 A short-circuit current by 1.56 equals 6.33 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Tesla Inc SR86T3R pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 29.03 V cold Voc at 14 F and handles 4.06 A Isc; string inverters cap Tesla Inc SR86T3R at 20 panels on 600 V.

### Is Tesla Inc SR86T3R eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Tesla Inc SR86T3R rely on utility bill offset (~$2,022/yr at 8 kW) rather than 25D.

## Related Pages

Compare Tesla Inc equipment, Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85 specs, utility payback rates, and NEC string calculators alongside Tesla Inc SR86T3R.

[All Tesla Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc T430S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/)
- [Tesla Inc TSP-430](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/)
- [Tesla Inc T420S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/)
- [Tesla Inc TSP-415](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/)
- [Tesla Inc T400H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/)