---
title: "Tesla Inc SR72T2 Specs (72.0W, 14.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr72t2/
description: "CEC datasheet for Tesla Inc SR72T2: 72.0W STC, 14.2V Voc, 112-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Tesla Inc SR72T2 — CEC Solar Module Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc SR72T2 is a 72.0 W STC (65.4 W PTC) Mono-c-Si solar module ranking #21,628 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 14.69% efficiency, 14.2 V Voc at 25 C, and 15.52 V cold Voc at -10 C (38 panels max per 600 V string).

- **STC Wattage** : 72.0 W

- **PTC Wattage** : 65.4 W

- **Voc @ 25C** : 14.2 V

- **Efficiency** : 14.69%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc SR72T2 Compare Against Peer CEC Listings?

How Tesla Inc Tesla Inc SR72T2 handles rooftop heat (65.4 W PTC), 8 kW sizing, and cold winter string voltage.

Tesla Inc builds the Tesla Inc SR72T2 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 146.9 W/m2 (5.22 percentage points below 19.91% CEC median). Compared against SUNSTYLE AG / LTD SUNSTYLE M75 (75.0 W), this model holds typical 90.8% PTC-to-STC thermal output (65.4 W real-world rating). Lower 14.2 V string voltage fits 38 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 10.61 A overcurrent floor served by a 15 A breaker.

## Where Does Tesla Inc SR72T2 Fall Across Listed CEC Models?

Where Tesla Inc SR72T2 (72.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Tesla Inc SR72T2?

Percentile placement of Tesla Inc SR72T2 across power density (146.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Tesla Inc SR72T2?

Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR72T2 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #21,628 / 21,677

### 72.0 W STC · Higher Than 0.2%

72.0 W STC (-313.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,164

### 14.69% Aperture Efficiency

Power density 146.9 W/m2 (5.22 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 38 Panels Max @ -10 C (600 V)

Cold Voc reaches 15.52 V at -10 C (589.8 V string) and 15.9 V at -20 C (37 max).

 8 kW Reference Array

### 112 Panels = 8,064 W STC

Occupies 54.9 m2 (591 sq ft) producing 7,325 W PTC; NEC 690.8 OCPD floor is 10.61 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 14.2 * (1 + (-0.266/100) * (-10 - 25)) = 15.52 V | OCPD = 1.56 * 6.8 = 10.61 A

Inputs from CEC Modules.csv for Tesla Inc SR72T2: Voc=14.2 V, beta_Voc=-0.266%/C, Isc=6.8 A, STC=72.0 W, Area=0.49 m2.

**Result:** 38 panels max on 600 V (589.8 V); 112 panels for 8 kW (591 sq ft).

## What Are the Published CEC Specifications for Tesla Inc SR72T2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR72T2.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR72T2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 72.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 65.4 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 14.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 6.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 11.3 V / 6.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.266 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.69% (0.49 m2) | Array roof footprint density |
| **Cell Count & Technology** | 21 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Tesla Inc SR72T2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR72T2 (72.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 84 | 6.05 kW | 443 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 112 | 8.06 kW | 591 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 139 | 10.01 kW | 733 sq ft | $2,505 | $4,236 |

## How Many Tesla Inc SR72T2 Modules Fit in a Cold-Weather String?

Maximum series module counts for Tesla Inc SR72T2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=14.2V and beta_Voc=-0.266%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 15.9 V | 37 panels | 588.3 V | 62 panels |
| **-10 C (14 F)** | 15.52 V | 38 panels | 589.8 V | 64 panels |
| **0 C (32 F)** | 15.14 V | 39 panels | 590.5 V | 66 panels |
| **25 C (77 F STC)** | 14.2 V | 42 panels | 596.4 V | 70 panels |

## Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR72T2?

Alternative CEC solar modules from competing brands near Tesla Inc SR72T2 (72.0 W), including SUNSTYLE AG / LTD SUNSTYLE M75.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**SUNSTYLE AG / LTD SUNSTYLE M75**](https://epri-peac.com/solar-equipment/modules/sunstyle-ag-ltd/sunstyle-ag-ltd-sunstyle-m75/) SUNSTYLE AG / LTD | 75.0 W | +3.0 W | 15.6 V | 10.49% | 90.9% |
| [**Midsummer AB SLIM 2 x 10 65**](https://epri-peac.com/solar-equipment/modules/midsummer-ab/midsummer-ab-slim-2-x-10-65/) Midsummer AB | 65.0 W | -7.0 W | 12.6 V | 10.0% | 82.5% |
| [**SUNSTYLE AG / LTD SUNSTYLE M80**](https://epri-peac.com/solar-equipment/modules/sunstyle-ag-ltd/sunstyle-ag-ltd-sunstyle-m80/) SUNSTYLE AG / LTD | 80.0 W | +8.0 W | 15.7 V | 11.19% | 91.0% |
| [**Arka Energy Inc AEP-821-00012-A**](https://epri-peac.com/solar-equipment/modules/arka-energy-inc/arka-energy-inc-aep-821-00012-a/) Arka Energy Inc | 77.0 W | +5.0 W | 11.56 V | 14.81% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc SR72T2?

Evaluate Tesla Inc SR72T2 (72.0 W STC, 14.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR72T2 reaches 15.9 V per panel—exceeding 37 panels in series voids 600 V inverter warranties.
- Footprint constraint: 112 panels for an 8 kW build require 591 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 112 panels (591 sq ft).
- 2026 tax credit baseline: cash residential installs of Tesla Inc SR72T2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Tesla Inc SR72T2 8 kW Residential Fit

Needs 112 modules (591 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 38 panels (-10 C) or 37 panels (-20 C), or compare SUNSTYLE AG / LTD SUNSTYLE M75.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 65.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR72T2 by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Tesla Inc SR72T2?

Multiplying Tesla Inc SR72T2's 6.8 A short-circuit current by 1.56 equals 10.61 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Tesla Inc SR72T2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 15.52 V cold Voc at 14 F and handles 6.8 A Isc; string inverters cap Tesla Inc SR72T2 at 38 panels on 600 V.

### Is Tesla Inc SR72T2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Tesla Inc SR72T2 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Tesla Inc equipment, SUNSTYLE AG / LTD SUNSTYLE M75 specs, utility payback rates, and NEC string calculators alongside Tesla Inc SR72T2.

[All Tesla Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc T430S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/)
- [Tesla Inc TSP-430](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/)
- [Tesla Inc T420S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/)
- [Tesla Inc TSP-415](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/)
- [Tesla Inc T400H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/)
