# Tesla Inc SR24T3-2 — CEC Solar Module Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc SR24T3-2 is a 23.8 W STC (20.5 W PTC) Multi-c-Si solar module ranking #21,675 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 9.9% efficiency, 3.8 V Voc at 25 C, and 4.23 V cold Voc at -10 C (141 panels max per 600 V string).

- **STC Wattage** : 23.8 W

- **PTC Wattage** : 20.5 W

- **Voc @ 25C** : 3.8 V

- **Efficiency** : 9.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc SR24T3-2 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Tesla Inc SR24T3-2 (Multi-c-Si) residential solar systems.

Tesla Inc SR24T3-2 delivers 99.2 W/m2 (10.01 percentage points below 19.91% CEC median) and typical 86.3% PTC-to-STC thermal output (20.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 337 panels (871 sq ft). At -4 F (-20 C), string voltage climbs to 4.36 V per unit, capping 600 V circuits at 137 panels. Compare specs directly with Jackery Inc JS-36A (36.0 W).

## Where Does Tesla Inc SR24T3-2 Fall Across Listed CEC Models?

Comparison of Tesla Inc SR24T3-2 (23.8 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

## What Dataset Percentiles Define Tesla Inc SR24T3-2?

Relative ranking of Tesla Inc SR24T3-2 across nameplate watts, 86.3% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Do the Dataset Ranks Show for Tesla Inc SR24T3-2?

Summary of Tesla Inc SR24T3-2 output rank, 8 kW array size (337 panels), efficiency rating, and 600 V string limit.

Rank #21,675 / 21,677

### 23.8 W STC · Higher Than 0.0%

23.8 W STC (-361.2 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,629

### 9.9% Aperture Efficiency

Power density 99.2 W/m2 (10.01 percentage points below 19.91% CEC median). PTC/STC ratio: 86.3% (rank #21,635).

NEC 690.7 Limit

### 141 Panels Max @ -10 C (600 V)

Cold Voc reaches 4.23 V at -10 C (596.4 V string) and 4.36 V at -20 C (137 max).

 8 kW Reference Array

### 337 Panels = 8,021 W STC

Occupies 80.9 m2 (871 sq ft) producing 6,908 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 3.8 * (1 + (-0.325/100) * (-10 - 25)) = 4.23 V | OCPD = 1.56 * 8.35 = 13.03 A

Inputs from CEC Modules.csv for Tesla Inc SR24T3-2: Voc=3.8 V, beta_Voc=-0.325%/C, Isc=8.35 A, STC=23.8 W, Area=0.24 m2.

**Result:** 141 panels max on 600 V (596.4 V); 337 panels for 8 kW (871 sq ft).

## What Are the Published CEC Specifications for Tesla Inc SR24T3-2?

Complete CEC test sheet for Tesla Inc SR24T3-2 including Isc (8.35 A), Voc (3.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR24T3-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 23.8 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 20.5 W (86.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 3.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 3.04 V / 7.8 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.325 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 9.9% (0.24 m2) | Array roof footprint density |
| **Cell Count & Technology** | 6 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Tesla Inc SR24T3-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Tesla Inc SR24T3-2.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 253 | 6.02 kW | 654 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 337 | 8.02 kW | 871 sq ft | $2,007 | $3,394 |
| **10 kW Class** | 421 | 10.02 kW | 1,088 sq ft | $2,508 | $4,241 |

## How Many Tesla Inc SR24T3-2 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Tesla Inc SR24T3-2 (3.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=3.8V and beta_Voc=-0.325%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 4.36 V | 137 panels | 597.3 V | 229 panels |
| **-10 C (14 F)** | 4.23 V | 141 panels | 596.4 V | 236 panels |
| **0 C (32 F)** | 4.11 V | 145 panels | 596.0 V | 243 panels |
| **25 C (77 F STC)** | 3.8 V | 157 panels | 596.6 V | 263 panels |

## Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR24T3-2?

Four comparable CEC modules such as Jackery Inc JS-36A (36.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Jackery Inc JS-36A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-36a/) Jackery Inc | 36.0 W | +12.2 W | 5.54 V | 12.29% | 90.8% |
| [**Jackery Inc JS-38A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-38a/) Jackery Inc | 38.0 W | +14.2 W | 5.54 V | 12.97% | 91.1% |
| [**Jackery Inc JS-42A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-42a/) Jackery Inc | 42.0 W | +18.2 W | 5.54 V | 14.33% | 92.4% |
| [**Jackery Inc JS-45A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-45a/) Jackery Inc | 45.0 W | +21.2 W | 5.54 V | 15.36% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc SR24T3-2?

Evaluate Tesla Inc SR24T3-2 (23.8 W STC, 3.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR24T3-2 reaches 4.36 V per panel—exceeding 137 panels in series voids 600 V inverter warranties.
- Footprint constraint: 337 panels for an 8 kW build require 871 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 337 panels (871 sq ft).
- 2026 tax credit baseline: cash residential installs of Tesla Inc SR24T3-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Tesla Inc SR24T3-2 8 kW Residential Fit

Needs 337 modules (871 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 141 panels (-10 C) or 137 panels (-20 C), or compare Jackery Inc JS-36A.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 20.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR24T3-2 by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Tesla Inc SR24T3-2 panels fit on a 600 V winter solar string?

At -10 C (14 F), Tesla Inc SR24T3-2 cold Voc rises from 3.8 V to 4.23 V (beta_Voc -0.325%/C), capping a 600 V string at 141 panels (596.4 V).

### How much roof area does an 8 kW array of Tesla Inc SR24T3-2 need?

An 8 kW DC system uses 337 Tesla Inc SR24T3-2 modules (8,021 W STC / 6,908 W PTC), covering roughly 871 sq ft and saving ~$2,007/yr at 18.54 c/kWh.

### How does Tesla Inc SR24T3-2 compare against Jackery Inc JS-36A?

Tesla Inc SR24T3-2 outputs 23.8 W STC (3.8 V Voc, rank #21,675 of 21,677), while Jackery Inc JS-36A delivers 36.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Tesla Inc equipment, Jackery Inc JS-36A specs, utility payback rates, and NEC string calculators alongside Tesla Inc SR24T3-2.

[All Tesla Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc T430S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/)
- [Tesla Inc TSP-430](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/)
- [Tesla Inc T420S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/)
- [Tesla Inc TSP-415](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/)
- [Tesla Inc T400H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/)