title: "Tesla Inc SR24S3-2 Specs (23.8W, 3.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-sr24s3-2/
description: "CEC datasheet for Tesla Inc SR24S3-2: 23.8W STC, 3.8V Voc, 337-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Tesla Inc SR24S3-2 — CEC Solar Module Specifications

Manufacturer: [**Tesla Inc**](https://epri-peac.com/solar-equipment/brands/tesla-inc/) Registry: **CEC Verified Engineering Specification**

Tesla Inc SR24S3-2 is a 23.8 W STC (20.5 W PTC) Multi-c-Si solar module ranking #21,675 of 21,677 CEC listings (below all-CEC median; higher than 0.0% of peers). It delivers 9.9% efficiency, 3.8 V Voc at 25 C, and 4.23 V cold Voc at -10 C (141 panels max per 600 V string).

- **STC Wattage** : 23.8 W

- **PTC Wattage** : 20.5 W

- **Voc @ 25C** : 3.8 V

- **Efficiency** : 9.9%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Tesla Inc SR24S3-2 Compare Against Peer CEC Listings?

How Tesla Inc Tesla Inc SR24S3-2 handles rooftop heat (20.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Tesla Inc SR24S3-2 exhibits 8.35 A short-circuit current, requiring a 13.03 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,675 of 21,677 (255.0 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 80.9 m2 for an 8 kW system (421 panels for 10 kW). Lower 3.8 V string voltage fits 141 panels in series at 14 F and pairs easily with microinverters.

## Where Does Tesla Inc SR24S3-2 Fall Across Listed CEC Models?

Where Tesla Inc SR24S3-2 (23.8 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Tesla Inc SR24S3-2?

Percentile placement of Tesla Inc SR24S3-2 across power density (99.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Tesla Inc SR24S3-2?

Four critical engineering numbers homeowners and solar installers check first when reviewing Tesla Inc SR24S3-2 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #21,675 / 21,677

### 23.8 W STC · Higher Than 0.0%

23.8 W STC (-361.2 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,629

### 9.9% Aperture Efficiency

Power density 99.2 W/m2 (10.01 percentage points below 19.91% CEC median). PTC/STC ratio: 86.3% (rank #21,635).

NEC 690.7 Limit

### 141 Panels Max @ -10 C (600 V)

Cold Voc reaches 4.23 V at -10 C (596.4 V string) and 4.36 V at -20 C (137 max).

 8 kW Reference Array

### 337 Panels = 8,021 W STC

Occupies 80.9 m2 (871 sq ft) producing 6,908 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 3.8 * (1 + (-0.325/100) * (-10 - 25)) = 4.23 V | OCPD = 1.56 * 8.35 = 13.03 A

Inputs from CEC Modules.csv for Tesla Inc SR24S3-2: Voc=3.8 V, beta_Voc=-0.325%/C, Isc=8.35 A, STC=23.8 W, Area=0.24 m2.

**Result:** 141 panels max on 600 V (596.4 V); 337 panels for 8 kW (871 sq ft).

## What Are the Published CEC Specifications for Tesla Inc SR24S3-2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Tesla Inc SR24S3-2.

Official California Energy Commission (NREL SAM) test parameters for Tesla Inc SR24S3-2.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 23.8 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 20.5 W (86.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 3.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 3.04 V / 7.8 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.325 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 9.9% (0.24 m2) | Array roof footprint density |
| **Cell Count & Technology** | 6 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Tesla Inc SR24S3-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Tesla Inc SR24S3-2 (23.8 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 253 | 6.02 kW | 654 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 337 | 8.02 kW | 871 sq ft | $2,007 | $3,394 |
| **10 kW Class** | 421 | 10.02 kW | 1,088 sq ft | $2,508 | $4,241 |

## How Many Tesla Inc SR24S3-2 Modules Fit in a Cold-Weather String?

Maximum series module counts for Tesla Inc SR24S3-2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=3.8V and beta_Voc=-0.325%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 4.36 V | 137 panels | 597.3 V | 229 panels |
| **-10 C (14 F)** | 4.23 V | 141 panels | 596.4 V | 236 panels |
| **0 C (32 F)** | 4.11 V | 145 panels | 596.0 V | 243 panels |
| **25 C (77 F STC)** | 3.8 V | 157 panels | 596.6 V | 263 panels |

## Which Cross-Brand Solar Modules Compare Closest to Tesla Inc SR24S3-2?

Alternative CEC solar modules from competing brands near Tesla Inc SR24S3-2 (23.8 W), including Jackery Inc JS-36A. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Jackery Inc JS-36A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-36a/) Jackery Inc | 36.0 W | +12.2 W | 5.54 V | 12.29% | 90.8% |
| [**Jackery Inc JS-38A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-38a/) Jackery Inc | 38.0 W | +14.2 W | 5.54 V | 12.97% | 91.1% |
| [**Jackery Inc JS-42A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-42a/) Jackery Inc | 42.0 W | +18.2 W | 5.54 V | 14.33% | 92.4% |
| [**Jackery Inc JS-45A**](https://epri-peac.com/solar-equipment/modules/jackery-inc/jackery-inc-js-45a/) Jackery Inc | 45.0 W | +21.2 W | 5.54 V | 15.36% | 92.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Tesla Inc SR24S3-2?

Evaluate Tesla Inc SR24S3-2 (23.8 W STC, 3.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Tesla Inc SR24S3-2 reaches 4.36 V per panel—exceeding 137 panels in series voids 600 V inverter warranties.
- Footprint constraint: 337 panels for an 8 kW build require 871 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 337 panels (871 sq ft).
- 2026 tax credit baseline: cash residential installs of Tesla Inc SR24S3-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Tesla Inc SR24S3-2 8 kW Residential Fit

Needs 337 modules (871 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 141 panels (-10 C) or 137 panels (-20 C), or compare Jackery Inc JS-36A.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 20.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Tesla Inc SR24S3-2 by Tesla Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Tesla Inc SR24S3-2 PTC wattage (20.5 W) lower than STC (23.8 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 20.5 W PTC (86.3% retention) across Tesla Inc SR24S3-2's 0.24 m2 aperture.

### Who should skip Tesla Inc SR24S3-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 337 Tesla Inc SR24S3-2 panels (871 sq ft) leave unusable roof gaps vs. Jackery Inc JS-36A.

### What is the 1,000 V commercial string limit for Tesla Inc SR24S3-2?

On 1,000 V commercial inverters at -10 C (4.23 V cold Voc), Tesla Inc SR24S3-2 fits up to 236 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Tesla Inc SR24S3-2.

## Related Pages

Compare Tesla Inc equipment, Jackery Inc JS-36A specs, utility payback rates, and NEC string calculators alongside Tesla Inc SR24S3-2.

[All Tesla Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/tesla-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Tesla Inc

- [All Tesla Inc Specs](https://epri-peac.com/solar-equipment/brands/tesla-inc/)
- [Tesla Inc T430S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t430s/)
- [Tesla Inc TSP-430](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-430/)
- [Tesla Inc T420S](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t420s/)
- [Tesla Inc TSP-415](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-tsp-415/)
- [Tesla Inc T400H](https://epri-peac.com/solar-equipment/modules/tesla-inc/tesla-inc-t400h/)