title: "T-Solar Global TS410 Specs (410.0W, 191.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts410/
description: "CEC datasheet for T-Solar Global TS410: 410.0W STC, 191.0V Voc, 20-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# T-Solar Global TS410 — CEC Solar Module Specifications

Manufacturer: [**T-Solar Global**](https://epri-peac.com/solar-equipment/brands/t-solar-global/) Registry: **CEC Verified Engineering Specification**

T-Solar Global TS410 is a 410.0 W STC (381.1 W PTC) Thin Film solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 7.18% efficiency, 191.0 V Voc at 25 C, and 213.06 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 381.1 W

- **Voc @ 25C** : 191.0 V

- **Efficiency** : 7.18%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does T-Solar Global TS410 Compare Against Peer CEC Listings?

How T-Solar Global T-Solar Global TS410 handles rooftop heat (381.1 W PTC), 8 kW sizing, and cold winter string voltage.

T-Solar Global builds the T-Solar Global TS410 (Thin Film) as a modern high-density residential and light-commercial module delivering 71.8 W/m2 (12.73 percentage points below 19.91% CEC median). Compared against Applied Materials Full Size Single Junction Version 10 (414.0 W), this model holds strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Higher 191.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 5.12 A overcurrent floor served by a 15 A breaker.

## Where Does T-Solar Global TS410 Fall Across Listed CEC Models?

Where T-Solar Global TS410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define T-Solar Global TS410?

Percentile placement of T-Solar Global TS410 across power density (71.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for T-Solar Global TS410?

Four critical engineering numbers homeowners and solar installers check first when reviewing T-Solar Global TS410 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,662

### 7.18% Aperture Efficiency

Power density 71.8 W/m2 (12.73 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 213.06 V at -10 C (426.1 V string) and 219.36 V at -20 C (2 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 114.2 m2 (1,229 sq ft) producing 7,622 W PTC; NEC 690.8 OCPD floor is 5.12 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 191.0 * (1 + (-0.33/100) * (-10 - 25)) = 213.06 V | OCPD = 1.56 * 3.28 = 5.12 A

Inputs from CEC Modules.csv for T-Solar Global TS410: Voc=191.0 V, beta_Voc=-0.33%/C, Isc=3.28 A, STC=410.0 W, Area=5.71 m2.

**Result:** 2 panels max on 600 V (426.1 V); 20 panels for 8 kW (1,229 sq ft).

## What Are the Published CEC Specifications for T-Solar Global TS410?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for T-Solar Global TS410.

Official California Energy Commission (NREL SAM) test parameters for T-Solar Global TS410.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 381.1 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 191.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 149.0 V / 2.78 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 7.18% (5.71 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many T-Solar Global TS410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using T-Solar Global TS410 (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 922 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 1,229 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 1,537 sq ft | $2,565 | $4,338 |

## How Many T-Solar Global TS410 Modules Fit in a Cold-Weather String?

Maximum series module counts for T-Solar Global TS410 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=191.0V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 219.36 V | 2 panels | 438.7 V | 4 panels |
| **-10 C (14 F)** | 213.06 V | 2 panels | 426.1 V | 4 panels |
| **0 C (32 F)** | 206.76 V | 2 panels | 413.5 V | 4 panels |
| **25 C (77 F STC)** | 191.0 V | 3 panels | 573.0 V | 5 panels |

## Which Cross-Brand Solar Modules Compare Closest to T-Solar Global TS410?

Alternative CEC solar modules from competing brands near T-Solar Global TS410 (410.0 W), including Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Applied Materials Full Size Single Junction Version 10**](https://epri-peac.com/solar-equipment/modules/applied-materials/applied-materials-full-size-single-junction-version-10/) Applied Materials | 414.0 W | +4.0 W | 194.2 V | 7.24% | 92.9% |
| [**CSI Solar Co Ltd CS1Y-410MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs1y-410ms/) CSI Solar Co Ltd | 410.0 W | Tie (0 W) | 52.7 V | 21.03% | 94.1% |
| [**Auxin Solar AXNG1M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410b/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| [**Auxin Solar AXNG1M410W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axng1m410w/) Auxin Solar | 410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for T-Solar Global TS410?

Evaluate T-Solar Global TS410 (410.0 W STC, 191.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), T-Solar Global TS410 reaches 219.36 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 1,229 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (1,229 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of T-Solar Global TS410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### T-Solar Global TS410 8 kW Residential Fit

Needs 20 modules (1,229 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for T-Solar Global TS410 by T-Solar Global grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for T-Solar Global TS410?

Multiplying T-Solar Global TS410's 3.28 A short-circuit current by 1.56 equals 5.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can T-Solar Global TS410 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 213.06 V cold Voc at 14 F and handles 3.28 A Isc; string inverters cap T-Solar Global TS410 at 2 panels on 600 V.

### Is T-Solar Global TS410 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of T-Solar Global TS410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare T-Solar Global equipment, Applied Materials Full Size Single Junction Version 10 specs, utility payback rates, and NEC string calculators alongside T-Solar Global TS410.

[All T-Solar Global Certified Solar Models](https://epri-peac.com/solar-equipment/brands/t-solar-global/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From T-Solar Global

- [All T-Solar Global Specs](https://epri-peac.com/solar-equipment/brands/t-solar-global/)
- [T-Solar Global TS390](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts390/)
- [T-Solar Global TS370](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts370/)
- [T-Solar Global TS102](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/)
- [T-Solar Global TS97](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/)