title: "T-Solar Global TS370 Specs (370.0W, 185.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts370/
description: "CEC datasheet for T-Solar Global TS370: 370.0W STC, 185.0V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# T-Solar Global TS370 — CEC Solar Module Specifications

Manufacturer: [**T-Solar Global**](https://epri-peac.com/solar-equipment/brands/t-solar-global/) Registry: **CEC Verified Engineering Specification**

T-Solar Global TS370 is a 370.0 W STC (343.6 W PTC) Thin Film solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 6.48% efficiency, 185.0 V Voc at 25 C, and 206.37 V cold Voc at -10 C (2 panels max per 600 V string).

- **STC Wattage** : 370.0 W

- **PTC Wattage** : 343.6 W

- **Voc @ 25C** : 185.0 V

- **Efficiency** : 6.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does T-Solar Global TS370 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for T-Solar Global TS370 (Thin Film) residential solar systems.

T-Solar Global TS370 delivers 64.8 W/m2 (13.43 percentage points below 19.91% CEC median) and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (1,352 sq ft). At -4 F (-20 C), string voltage climbs to 212.47 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with DEHUI SOLAR POWER INC DH-72M-375W (375.0 W).

## Where Does T-Solar Global TS370 Fall Across Listed CEC Models?

Comparison of T-Solar Global TS370 (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define T-Solar Global TS370?

Relative ranking of T-Solar Global TS370 across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do the Dataset Ranks Show for T-Solar Global TS370?

Summary of T-Solar Global TS370 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

### 370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,674

### 6.48% Aperture Efficiency

Power density 64.8 W/m2 (13.43 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 2 Panels Max @ -10 C (600 V)

Cold Voc reaches 206.37 V at -10 C (412.7 V string) and 212.47 V at -20 C (2 max).

 8 kW Reference Array

### 22 Panels = 8,140 W STC

Occupies 125.6 m2 (1,352 sq ft) producing 7,559 W PTC; NEC 690.8 OCPD floor is 5.05 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 185.0 * (1 + (-0.33/100) * (-10 - 25)) = 206.37 V | OCPD = 1.56 * 3.24 = 5.05 A

Inputs from CEC Modules.csv for T-Solar Global TS370: Voc=185.0 V, beta_Voc=-0.33%/C, Isc=3.24 A, STC=370.0 W, Area=5.71 m2.

**Result:** 2 panels max on 600 V (412.7 V); 22 panels for 8 kW (1,352 sq ft).

## What Are the Published CEC Specifications for T-Solar Global TS370?

Complete CEC test sheet for T-Solar Global TS370 including Isc (3.24 A), Voc (185.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for T-Solar Global TS370.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 343.6 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 185.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 3.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 141.0 V / 2.71 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.33 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 6.48% (5.71 m2) | Array roof footprint density |
| **Cell Count & Technology** | 216 cells (Thin Film) | Monofacial backsheet |

## How Many T-Solar Global TS370 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using T-Solar Global TS370.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 17 | 6.29 kW | 1,045 sq ft | $1,574 | $2,662 |
| **8 kW Class** | 22 | 8.14 kW | 1,352 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 28 | 10.36 kW | 1,721 sq ft | $2,593 | $4,385 |

## How Many T-Solar Global TS370 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for T-Solar Global TS370 (185.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=185.0V and beta_Voc=-0.33%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 212.47 V | 2 panels | 424.9 V | 4 panels |
| **-10 C (14 F)** | 206.37 V | 2 panels | 412.7 V | 4 panels |
| **0 C (32 F)** | 200.26 V | 2 panels | 400.5 V | 4 panels |
| **25 C (77 F STC)** | 185.0 V | 3 panels | 555.0 V | 5 panels |

## Which Cross-Brand Solar Modules Compare Closest to T-Solar Global TS370?

Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72M-375W (375.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**DEHUI SOLAR POWER INC DH-72M-375W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-inc/dehui-solar-power-inc-dh-72m-375w/) DEHUI SOLAR POWER INC | 375.0 W | +5.0 W | 50.1 V | 19.5% | 91.5% |
| [**Caterpillar Inc PVC370MP03H**](https://epri-peac.com/solar-equipment/modules/caterpillar-inc/caterpillar-inc-pvc370mp03h/) Caterpillar Inc | 370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| [**Bluesun Solar Energy Tech CoLtd BSM370M-72**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm370m-72/) Bluesun Solar Energy Tech CoLtd | 370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| [**CertainTeed CT370M00-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct370m00-04/) CertainTeed | 370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for T-Solar Global TS370?

Evaluate T-Solar Global TS370 (370.0 W STC, 185.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), T-Solar Global TS370 reaches 212.47 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 1,352 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (1,352 sq ft).
- 2026 tax credit baseline: cash residential installs of T-Solar Global TS370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### T-Solar Global TS370 8 kW Residential Fit

Needs 22 modules (1,352 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72M-375W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 343.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for T-Solar Global TS370 by T-Solar Global grounded in CEC test data and NEC 690.7/690.8 limits.

### How many T-Solar Global TS370 panels fit on a 600 V winter solar string?

At -10 C (14 F), T-Solar Global TS370 cold Voc rises from 185.0 V to 206.37 V (beta_Voc -0.33%/C), capping a 600 V string at 2 panels (412.7 V).

### How much roof area does an 8 kW array of T-Solar Global TS370 need?

An 8 kW DC system uses 22 T-Solar Global TS370 modules (8,140 W STC / 7,559 W PTC), covering roughly 1,352 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

### How does T-Solar Global TS370 compare against DEHUI SOLAR POWER INC DH-72M-375W?

T-Solar Global TS370 outputs 370.0 W STC (185.0 V Voc, rank #11,697 of 21,677), while DEHUI SOLAR POWER INC DH-72M-375W delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare T-Solar Global equipment, DEHUI SOLAR POWER INC DH-72M-375W specs, utility payback rates, and NEC string calculators alongside T-Solar Global TS370.

[All T-Solar Global Certified Solar Models](https://epri-peac.com/solar-equipment/brands/t-solar-global/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From T-Solar Global

- [All T-Solar Global Specs](https://epri-peac.com/solar-equipment/brands/t-solar-global/)
- [T-Solar Global TS410](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts410/)
- [T-Solar Global TS390](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts390/)
- [T-Solar Global TS102](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts102/)
- [T-Solar Global TS97](https://epri-peac.com/solar-equipment/modules/t-solar-global/t-solar-global-ts97/)