# Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 — CEC Solar Module Specifications

Manufacturer: [**Suzhou Talesun Solar Technologies Co Ltd**](https://epri-peac.com/solar-equipment/brands/suzhou-talesun-solar-technologies-co-ltd/) Registry: **CEC Verified Engineering Specification**

Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 is a 395.0 W STC (368.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.23% efficiency, 36.75 V Voc at 25 C, and 40.34 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 395.0 W

- **PTC Wattage** : 368.1 W

- **Voc @ 25C** : 36.75 V

- **Efficiency** : 20.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 Compare Against Peer CEC Listings?

How Suzhou Talesun Solar Technologies Co Ltd Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 handles rooftop heat (368.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 exhibits 13.69 A short-circuit current, requiring a 21.36 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 41.0 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.75 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 Fall Across Listed CEC Models?

Where Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

Percentile placement of Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 across power density (202.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 specifications.

Rank #9,869 / 21,677

### Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,658

### 20.23% Aperture Efficiency

Power density 202.3 W/m2 (0.32 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.34 V at -10 C (564.8 V string) and 41.36 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,295 W STC

Occupies 41.0 m2 (441 sq ft) producing 7,730 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.75 * (1 + (-0.279/100) * (-10 - 25)) = 40.34 V | OCPD = 1.56 * 13.69 = 21.36 A

Inputs from CEC Modules.csv for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395: Voc=36.75 V, beta_Voc=-0.279%/C, Isc=13.69 A, STC=395.0 W, Area=1.953 m2.

**Result:** 14 panels max on 600 V (564.8 V); 21 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395.

Official California Energy Commission (NREL SAM) test parameters for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 368.1 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.85 V / 12.81 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.279 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.23% (1.953 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| **8 kW Class** | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| **10 kW Class** | 26 | 10.27 kW | 547 sq ft | $2,570 | $4,347 |

## How Many Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 Modules Fit in a Cold-Weather String?

Maximum series module counts for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.75V and beta_Voc=-0.279%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.36 V | 14 panels | 579.0 V | 24 panels |
| **-10 C (14 F)** | 40.34 V | 14 panels | 564.8 V | 24 panels |
| **0 C (32 F)** | 39.31 V | 15 panels | 589.7 V | 25 panels |
| **25 C (77 F STC)** | 36.75 V | 16 panels | 588.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

Alternative CEC solar modules from competing brands near Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 (395.0 W), including AMPS Solar AMPS-395P-54BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AMPS Solar AMPS-395P-54BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-395p-54bb/) AMPS Solar | 395.0 W | Tie (0 W) | 36.75 V | 20.36% | 94.2% |
| [**Bluesun Solar CoLtd BSM395M10-54HPH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm395m10-54hph/) Bluesun Solar CoLtd | 395.0 W | Tie (0 W) | 36.75 V | 20.23% | 93.2% |
| [**Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-vietnam-coltd/dehui-solar-power-vietnam-coltd-dh-m154b-395w/) Dehui Solar Power (Vietnam) CoLtd | 395.0 W | Tie (0 W) | 36.74 V | 20.47% | 92.1% |
| [**ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E**](https://epri-peac.com/solar-equipment/modules/alternative-energy-ae-solar-co-ltd/alternative-energy-ae-solar-co-ltd-ae395md-108e/) ALTERNATIVE ENERGY (AE) SOLAR CO LTD | 395.0 W | Tie (0 W) | 36.7 V | 20.47% | 92.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

Evaluate Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 (395.0 W STC, 36.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 reaches 41.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AMPS Solar AMPS-395P-54BB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 by Suzhou Talesun Solar Technologies Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 PTC wattage (368.1 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 368.1 W PTC (93.2% retention) across Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395's 1.953 m2 aperture.

### Who should skip Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 panels (441 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-395P-54BB.

### What is the 1,000 V commercial string limit for Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395?

On 1,000 V commercial inverters at -10 C (40.34 V cold Voc), Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395 fits up to 24 panels per series string.

## Related Pages

Compare Suzhou Talesun Solar Technologies Co Ltd equipment, AMPS Solar AMPS-395P-54BB specs, utility payback rates, and NEC string calculators alongside Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395.

[All Suzhou Talesun Solar Technologies Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suzhou-talesun-solar-technologies-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suzhou Talesun Solar Technologies Co Ltd

- [All Suzhou Talesun Solar Technologies Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/suzhou-talesun-solar-technologies-co-ltd/)
- [Suzhou Talesun Solar Technologies Co Ltd TM8G66M-730](https://epri-peac.com/solar-equipment/modules/suzhou-talesun-solar-technologies-co-ltd/suzhou-talesun-solar-technologies-co-ltd-tm8g66m-730/)
- [Suzhou Talesun Solar Technologies Co Ltd TM8G66M-715](https://epri-peac.com/solar-equipment/modules/suzhou-talesun-solar-technologies-co-ltd/suzhou-talesun-solar-technologies-co-ltd-tm8g66m-715/)
- [Suzhou Talesun Solar Technologies Co Ltd TM7G78M-635](https://epri-peac.com/solar-equipment/modules/suzhou-talesun-solar-technologies-co-ltd/suzhou-talesun-solar-technologies-co-ltd-tm7g78m-635/)
- [Suzhou Talesun Solar Technologies Co Ltd TM7G78M-615](https://epri-peac.com/solar-equipment/modules/suzhou-talesun-solar-technologies-co-ltd/suzhou-talesun-solar-technologies-co-ltd-tm7g78m-615/)
- [Suzhou Talesun Solar Technologies Co Ltd TM3G66M-610](https://epri-peac.com/solar-equipment/modules/suzhou-talesun-solar-technologies-co-ltd/suzhou-talesun-solar-technologies-co-ltd-tm3g66m-610/)