# SunTegra STS-114M-B4U — CEC Solar Module Specifications

Manufacturer: [**SunTegra**](https://epri-peac.com/solar-equipment/brands/suntegra/) Registry: **CEC Verified Engineering Specification**

SunTegra STS-114M-B4U is a 114.0 W STC (98.9 W PTC) Mono-c-Si solar module ranking #21,518 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 17.27% efficiency, 15.52 V Voc at 25 C, and 17.1 V cold Voc at -10 C (35 panels max per 600 V string).

- **STC Wattage** : 114.0 W

- **PTC Wattage** : 98.9 W

- **Voc @ 25C** : 15.52 V

- **Efficiency** : 17.27%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SunTegra STS-114M-B4U Compare Against Peer CEC Listings?

Engineering position of SunTegra STS-114M-B4U (114.0 W STC) vs. Merlin Solar Technologies Inc FX110 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,518 across 21,677 CEC solar panels (below all-CEC median; higher than 0.7% of peers), SunTegra STS-114M-B4U operates as a compact residential or specialty off-grid module sitting 296.0 W below the 410.0 W Mono-c-Si median. Lower 15.52 V string voltage fits 35 panels in series at 14 F and pairs easily with microinverters. With typical 86.8% PTC-to-STC thermal output (98.9 W real-world rating), 71 panels occupy 504 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does SunTegra STS-114M-B4U Fall Across Listed CEC Models?

Plots SunTegra STS-114M-B4U at 114.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define SunTegra STS-114M-B4U?

Benchmarks SunTegra STS-114M-B4U on STC wattage, thermal PTC/STC retention, and 17.27 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for SunTegra STS-114M-B4U?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunTegra STS-114M-B4U by SunTegra.

Rank #21,518 / 21,677

### 114.0 W STC · Higher Than 0.7%

114.0 W STC (-271.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,091

### 17.27% Aperture Efficiency

Power density 172.7 W/m2 (2.64 percentage points below 19.91% CEC median). PTC/STC ratio: 86.8% (rank #21,603).

NEC 690.7 Limit

### 35 Panels Max @ -10 C (600 V)

Cold Voc reaches 17.1 V at -10 C (598.5 V string) and 17.55 V at -20 C (34 max).

 8 kW Reference Array

### 71 Panels = 8,094 W STC

Occupies 46.9 m2 (504 sq ft) producing 7,022 W PTC; NEC 690.8 OCPD floor is 15.1 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 15.52 * (1 + (-0.291/100) * (-10 - 25)) = 17.1 V | OCPD = 1.56 * 9.68 = 15.1 A

Inputs from CEC Modules.csv for SunTegra STS-114M-B4U: Voc=15.52 V, beta_Voc=-0.291%/C, Isc=9.68 A, STC=114.0 W, Area=0.66 m2.

**Result:** 35 panels max on 600 V (598.5 V); 71 panels for 8 kW (504 sq ft).

## What Are the Published CEC Specifications for SunTegra STS-114M-B4U?

Laboratory test ratings recorded for SunTegra STS-114M-B4U (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SunTegra STS-114M-B4U.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 114.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 98.9 W (86.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 15.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 12.78 V / 8.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.291 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.27% (0.66 m2) | Array roof footprint density |
| **Cell Count & Technology** | 24 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SunTegra STS-114M-B4U Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (504 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunTegra STS-114M-B4U.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 53 | 6.04 kW | 377 sq ft | $1,512 | $2,556 |
| **8 kW Class** | 71 | 8.09 kW | 504 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 88 | 10.03 kW | 625 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This SunTegra Series?

Sibling wattage bins and frame colors grouped with SunTegra STS-114M-B4U under SunTegra to prevent duplicate spec pages. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SunTegra STS-114M-B4U wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SunTegra STS-110M-B4U** | 110.0 W | 95.3 W | 15.46 V | 12.72 V | 16.67% |
| **SunTegra STS-114M-B4U** | 114.0 W | 98.9 W | 15.52 V | 12.78 V | 17.27% |

## How Many SunTegra STS-114M-B4U Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SunTegra STS-114M-B4U (beta_Voc -0.291%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=15.52V and beta_Voc=-0.291%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 17.55 V | 34 panels | 596.7 V | 56 panels |
| **-10 C (14 F)** | 17.1 V | 35 panels | 598.5 V | 58 panels |
| **0 C (32 F)** | 16.65 V | 36 panels | 599.4 V | 60 panels |
| **25 C (77 F STC)** | 15.52 V | 38 panels | 589.8 V | 64 panels |

## Which Cross-Brand Solar Modules Compare Closest to SunTegra STS-114M-B4U?

Closest cross-brand CEC competitors to SunTegra STS-114M-B4U matched near 114.0 W STC and 15.52 V Voc, led by Merlin Solar Technologies Inc FX110.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Merlin Solar Technologies Inc FX110**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fx110/) Merlin Solar Technologies Inc | 110.0 W | -4.0 W | 15.6 V | 14.53% | 91.5% |
| [**Merlin Solar Technologies Inc RFP-F024B117L**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-rfp-f024b117l/) Merlin Solar Technologies Inc | 117.0 W | +3.0 W | 16.3 V | 15.39% | 89.5% |
| [**SunStyle M110 870**](https://epri-peac.com/solar-equipment/modules/sunstyle/sunstyle-m110-870/) SunStyle | 110.0 W | -4.0 W | 16.1 V | 14.47% | 89.3% |
| [**Merlin Solar Technologies Inc FXS 105-W**](https://epri-peac.com/solar-equipment/modules/merlin-solar-technologies-inc/merlin-solar-technologies-inc-fxs-105-w/) Merlin Solar Technologies Inc | 105.0 W | -9.0 W | 15.5 V | 14.0% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SunTegra STS-114M-B4U?

Evaluate SunTegra STS-114M-B4U (114.0 W STC, 15.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SunTegra STS-114M-B4U reaches 17.55 V per panel—exceeding 34 panels in series voids 600 V inverter warranties.
- Footprint constraint: 71 panels for an 8 kW build require 504 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 71 panels (504 sq ft).
- 2026 tax credit baseline: cash residential installs of SunTegra STS-114M-B4U carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SunTegra STS-114M-B4U 8 kW Residential Fit

Needs 71 modules (504 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 35 panels (-10 C) or 34 panels (-20 C), or compare Merlin Solar Technologies Inc FX110.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 98.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunTegra STS-114M-B4U by SunTegra grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

### How many SunTegra STS-114M-B4U panels fit on a 600 V winter solar string?

At -10 C (14 F), SunTegra STS-114M-B4U cold Voc rises from 15.52 V to 17.1 V (beta_Voc -0.291%/C), capping a 600 V string at 35 panels (598.5 V).

### How much roof area does an 8 kW array of SunTegra STS-114M-B4U need?

An 8 kW DC system uses 71 SunTegra STS-114M-B4U modules (8,094 W STC / 7,022 W PTC), covering roughly 504 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

### How does SunTegra STS-114M-B4U compare against Merlin Solar Technologies Inc FX110?

SunTegra STS-114M-B4U outputs 114.0 W STC (15.52 V Voc, rank #21,518 of 21,677), while Merlin Solar Technologies Inc FX110 delivers 110.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare SunTegra equipment, Merlin Solar Technologies Inc FX110 specs, utility payback rates, and NEC string calculators alongside SunTegra STS-114M-B4U.

[All SunTegra Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntegra/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SunTegra

- [All SunTegra Specs](https://epri-peac.com/solar-equipment/brands/suntegra/)