Suntech Power STP310-24/Ver is a 310.0 W STC (281.2 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 45.2 V Voc at 25 C, and 51.97 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 281.2 W

- **Voc @ 25C** : 45.2 V

- **Efficiency** : 15.98%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP310-24/Ver Compare Against Peer CEC Listings?

How Suntech Power Suntech Power STP310-24/Ver handles rooftop heat (281.2 W PTC), 8 kW sizing, and cold winter string voltage.

Suntech Power builds the Suntech Power STP310-24/Ver (Multi-c-Si) as a compact residential or specialty off-grid module delivering 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). Compared against Advance Power API-P310 (310.0 W), this model holds typical 90.7% PTC-to-STC thermal output (281.2 W real-world rating). Mid-range 45.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.9 A overcurrent floor served by a 15 A breaker.

## Where Does Suntech Power STP310-24/Ver Fall Across Listed CEC Models?

Where Suntech Power STP310-24/Ver (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Suntech Power STP310-24/Ver?

Percentile placement of Suntech Power STP310-24/Ver across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Suntech Power STP310-24/Ver?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP310-24/Ver specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

### 15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.97 V at -10 C (571.7 V string) and 53.91 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.428/100) * (-10 - 25)) = 51.97 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for Suntech Power STP310-24/Ver: Voc=45.2 V, beta_Voc=-0.428%/C, Isc=8.91 A, STC=310.0 W, Area=1.94 m2.

**Result:** 11 panels max on 600 V (571.7 V); 26 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP310-24/Ver?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP310-24/Ver.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP310-24/Ver.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 281.2 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.1 V / 8.36 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.428 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.98% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP310-24/Ver Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP310-24/Ver (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 418 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 689 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

All closely matched Suntech Power wattages and cosmetic trims sharing the Suntech Power STP310-24/Ver architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Suntech Power STP310-24/Ver wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP300-24/Ver** | 300.0 W | 271.9 W | 45.0 V | 36.9 V | 15.46% |
| **Suntech Power STP305-24/Ver** | 305.0 W | 276.5 W | 45.1 V | 37.0 V | 15.72% |
| **Suntech Power STP310-24/Ver** | 310.0 W | 281.2 W | 45.2 V | 37.1 V | 15.98% |
| **Suntech Power STP315-24/Ver** | 315.0 W | 285.8 W | 45.5 V | 36.6 V | 16.23% |

## How Many Suntech Power STP310-24/Ver Modules Fit in a Cold-Weather String?

Maximum series module counts for Suntech Power STP310-24/Ver from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.2V and beta_Voc=-0.428%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.91 V | 11 panels | 593.0 V | 18 panels |
| **-10 C (14 F)** | 51.97 V | 11 panels | 571.7 V | 19 panels |
| **0 C (32 F)** | 50.04 V | 11 panels | 550.4 V | 19 panels |
| **25 C (77 F STC)** | 45.2 V | 13 panels | 587.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP310-24/Ver?

Alternative CEC solar modules from competing brands near Suntech Power STP310-24/Ver (310.0 W), including Advance Power API-P310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-P310**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p310/) Advance Power | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Auxin Solar AXN6P612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t310/) Auxin Solar | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Centrosolar America DP72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP310-24/Ver?

Evaluate Suntech Power STP310-24/Ver (310.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP310-24/Ver reaches 53.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP310-24/Ver carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP310-24/Ver 8 kW Residential Fit

Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP310-24/Ver by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Suntech Power STP310-24/Ver?

Multiplying Suntech Power STP310-24/Ver's 8.91 A short-circuit current by 1.56 equals 13.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Suntech Power STP310-24/Ver pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.97 V cold Voc at 14 F and handles 8.91 A Isc; string inverters cap Suntech Power STP310-24/Ver at 11 panels on 600 V.

### Is Suntech Power STP310-24/Ver eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP310-24/Ver rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Suntech Power equipment, Advance Power API-P310 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP310-24/Ver.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)