title: "Suntech Power STP310-24/Vdx Specs (310.0W, 45.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/
description: "CEC datasheet for Suntech Power STP310-24/Vdx: 310.0W STC, 45.2V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Suntech Power STP310-24/Vdx — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP310-24/Vdx is a 310.0 W STC (281.2 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.09% efficiency, 45.2 V Voc at 25 C, and 51.97 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 281.2 W

- **Voc @ 25C** : 45.2 V

- **Efficiency** : 16.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP310-24/Vdx Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suntech Power STP310-24/Vdx (Multi-c-Si) residential solar systems.

Suntech Power STP310-24/Vdx delivers 161.0 W/m2 (3.82 percentage points below 19.91% CEC median) and typical 90.7% PTC-to-STC thermal output (281.2 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (539 sq ft). At -4 F (-20 C), string voltage climbs to 53.91 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Advance Power API-P310 (310.0 W).

## Where Does Suntech Power STP310-24/Vdx Fall Across Listed CEC Models?

Comparison of Suntech Power STP310-24/Vdx (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Suntech Power STP310-24/Vdx?

Relative ranking of Suntech Power STP310-24/Vdx across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Suntech Power STP310-24/Vdx?

Summary of Suntech Power STP310-24/Vdx output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,001

### 16.09% Aperture Efficiency

Power density 161.0 W/m2 (3.82 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.97 V at -10 C (571.7 V string) and 53.91 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.1 m2 (539 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.428/100) * (-10 - 25)) = 51.97 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for Suntech Power STP310-24/Vdx: Voc=45.2 V, beta_Voc=-0.428%/C, Isc=8.91 A, STC=310.0 W, Area=1.926 m2.

**Result:** 11 panels max on 600 V (571.7 V); 26 panels for 8 kW (539 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP310-24/Vdx?

Complete CEC test sheet for Suntech Power STP310-24/Vdx including Isc (8.91 A), Voc (45.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP310-24/Vdx.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 281.2 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.91 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.1 V / 8.36 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.428 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.09% (1.926 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP310-24/Vdx Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suntech Power STP310-24/Vdx.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 415 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 539 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 684 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Related Suntech Power power steps and black/silver trims consolidated into this Suntech Power STP310-24/Vdx series guide.

Sibling CEC listings grouped into the Suntech Power STP310-24/Vdx wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP300-24/Vdx** | 300.0 W | 271.9 W | 45.0 V | 36.9 V | 15.46% |
| **Suntech Power STP305-24/Vdx** | 305.0 W | 276.5 W | 45.1 V | 37.0 V | 15.72% |
| **Suntech Power STP310-24/Vdx** | 310.0 W | 281.2 W | 45.2 V | 37.1 V | 16.09% |
| **Suntech Power STP315-24/Vdx** | 315.0 W | 285.8 W | 45.5 V | 36.6 V | 16.23% |
| **Suntech Power STP320-24/Vdx** | 320.0 W | 290.5 W | 45.6 V | 36.7 V | 16.49% |

## How Many Suntech Power STP310-24/Vdx Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Suntech Power STP310-24/Vdx (45.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.2V and beta_Voc=-0.428%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.91 V | 11 panels | 593.0 V | 18 panels |
| **-10 C (14 F)** | 51.97 V | 11 panels | 571.7 V | 19 panels |
| **0 C (32 F)** | 50.04 V | 11 panels | 550.4 V | 19 panels |
| **25 C (77 F STC)** | 45.2 V | 13 panels | 587.6 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP310-24/Vdx?

Four comparable CEC modules such as Advance Power API-P310 (310.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-P310**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p310/) Advance Power | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Auxin Solar AXN6P612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t310/) Auxin Solar | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Centrosolar America DP72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP310-24/Vdx?

Evaluate Suntech Power STP310-24/Vdx (310.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP310-24/Vdx reaches 53.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 539 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (539 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP310-24/Vdx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP310-24/Vdx 8 kW Residential Fit

Needs 26 modules (539 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP310-24/Vdx by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Suntech Power STP310-24/Vdx panels fit on a 600 V winter solar string?

At -10 C (14 F), Suntech Power STP310-24/Vdx cold Voc rises from 45.2 V to 51.97 V (beta_Voc -0.428%/C), capping a 600 V string at 11 panels (571.7 V).

### How much roof area does an 8 kW array of Suntech Power STP310-24/Vdx need?

An 8 kW DC system uses 26 Suntech Power STP310-24/Vdx modules (8,060 W STC / 7,311 W PTC), covering roughly 539 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does Suntech Power STP310-24/Vdx compare against Advance Power API-P310?

Suntech Power STP310-24/Vdx outputs 310.0 W STC (45.2 V Voc, rank #15,760 of 21,677), while Advance Power API-P310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Suntech Power equipment, Advance Power API-P310 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP310-24/Vdx.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)
- [Suntech Power STP310-24/Ver](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ver/)