title: "Suntech Power STP270-24/Vdx Specs (270.0W, 44.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp270-24-vdx/
description: "CEC datasheet for Suntech Power STP270-24/Vdx: 270.0W STC, 44.5V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Suntech Power STP270-24/Vdx — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP270-24/Vdx is a 270.0 W STC (244.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.92% efficiency, 44.5 V Voc at 25 C, and 49.37 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 270.0 W

- **PTC Wattage** : 244.7 W

- **Voc @ 25C** : 44.5 V

- **Efficiency** : 13.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP270-24/Vdx Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP270-24/Vdx: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 270.0 W STC and 244.7 W PTC, Suntech Power STP270-24/Vdx sits -115.0 W vs all-CEC median (below all-CEC median; higher than 12.9% of peers) among 21,677 listed modules. Power density reaches 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). Mid-range 44.5 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Advance Power API-M270 rates 270.0 W.

## Where Does Suntech Power STP270-24/Vdx Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP270-24/Vdx (270.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Suntech Power STP270-24/Vdx?

Dataset percentiles tracking Suntech Power STP270-24/Vdx power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Suntech Power STP270-24/Vdx?

Benchmark highlights for Suntech Power STP270-24/Vdx covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,572 / 21,677

### 270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,945

### 13.92% Aperture Efficiency

Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.37 V at -10 C (592.4 V string) and 50.77 V at -20 C (11 max).

 8 kW Reference Array

### 30 Panels = 8,100 W STC

Occupies 58.2 m2 (626 sq ft) producing 7,341 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.5 * (1 + (-0.313/100) * (-10 - 25)) = 49.37 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for Suntech Power STP270-24/Vdx: Voc=44.5 V, beta_Voc=-0.313%/C, Isc=8.2 A, STC=270.0 W, Area=1.94 m2.

**Result:** 12 panels max on 600 V (592.4 V); 30 panels for 8 kW (626 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP270-24/Vdx?

Official CEC datasheet figures for Suntech Power STP270-24/Vdx (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP270-24/Vdx.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 244.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.0 V / 7.71 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.313 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.92% (1.94 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP270-24/Vdx Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP270-24/Vdx modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.21 kW | 480 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 30 | 8.1 kW | 626 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 38 | 10.26 kW | 794 sq ft | $2,568 | $4,342 |

## How Many Suntech Power STP270-24/Vdx Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP270-24/Vdx (49.37 V at 14 F).

Computed from Voc=44.5V and beta_Voc=-0.313%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.77 V | 11 panels | 558.5 V | 19 panels |
| **-10 C (14 F)** | 49.37 V | 12 panels | 592.4 V | 20 panels |
| **0 C (32 F)** | 47.98 V | 12 panels | 575.8 V | 20 panels |
| **25 C (77 F STC)** | 44.5 V | 13 panels | 578.5 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP270-24/Vdx?

Competing CEC solar panels closest to Suntech Power STP270-24/Vdx in nameplate wattage and Voc, starting with Advance Power API-M270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M270**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m270/) Advance Power | 270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| [**Auxin Solar AXN6M612T270**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612t270/) Auxin Solar | 270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
| [**AXITEC AC-270P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-156-72s/) AXITEC | 270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| [**Centrosolar America DP72 270**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-270/) Centrosolar America | 270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP270-24/Vdx?

Evaluate Suntech Power STP270-24/Vdx (270.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP270-24/Vdx reaches 50.77 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP270-24/Vdx carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP270-24/Vdx 8 kW Residential Fit

Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M270.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 244.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP270-24/Vdx by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Suntech Power STP270-24/Vdx panels fit on a 600 V winter solar string?

At -10 C (14 F), Suntech Power STP270-24/Vdx cold Voc rises from 44.5 V to 49.37 V (beta_Voc -0.313%/C), capping a 600 V string at 12 panels (592.4 V).

### How much roof area does an 8 kW array of Suntech Power STP270-24/Vdx need?

An 8 kW DC system uses 30 Suntech Power STP270-24/Vdx modules (8,100 W STC / 7,341 W PTC), covering roughly 626 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does Suntech Power STP270-24/Vdx compare against Advance Power API-M270?

Suntech Power STP270-24/Vdx outputs 270.0 W STC (44.5 V Voc, rank #18,572 of 21,677), while Advance Power API-M270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Suntech Power equipment, Advance Power API-M270 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP270-24/Vdx.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)