title: "Suntech Power STP260-20/Wem Specs (260.0W, 37.7V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp260-20-wem/
description: "CEC datasheet for Suntech Power STP260-20/Wem: 260.0W STC, 37.7V Voc, 31-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Suntech Power STP260-20/Wem — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP260-20/Wem is a 260.0 W STC (237.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 37.7 V Voc at 25 C, and 42.2 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 237.4 W

- **Voc @ 25C** : 37.7 V

- **Efficiency** : 15.98%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP260-20/Wem Compare Against Peer CEC Listings?

How Suntech Power Suntech Power STP260-20/Wem handles rooftop heat (237.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Suntech Power STP260-20/Wem exhibits 8.89 A short-circuit current, requiring a 13.87 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,146 of 21,677 (18.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.4 m2 for an 8 kW system (39 panels for 10 kW). Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Suntech Power STP260-20/Wem Fall Across Listed CEC Models?

Where Suntech Power STP260-20/Wem (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Suntech Power STP260-20/Wem?

Percentile placement of Suntech Power STP260-20/Wem across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Suntech Power STP260-20/Wem?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP260-20/Wem specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

### 15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.2 V at -10 C (590.8 V string) and 43.49 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,359 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.341/100) * (-10 - 25)) = 42.2 V | OCPD = 1.56 * 8.89 = 13.87 A

Inputs from CEC Modules.csv for Suntech Power STP260-20/Wem: Voc=37.7 V, beta_Voc=-0.341%/C, Isc=8.89 A, STC=260.0 W, Area=1.627 m2.

**Result:** 14 panels max on 600 V (590.8 V); 31 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP260-20/Wem?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP260-20/Wem.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP260-20/Wem.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 237.4 W (91.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.9 V / 8.42 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.341 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.98% (1.627 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP260-20/Wem Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP260-20/Wem (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 683 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

All closely matched Suntech Power wattages and cosmetic trims sharing the Suntech Power STP260-20/Wem architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Suntech Power STP260-20/Wem wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP250-20/Wem** | 250.0 W | 228.1 W | 37.4 V | 30.7 V | 15.37% |
| **Suntech Power STP255-20/Wem** | 255.0 W | 232.8 W | 37.6 V | 30.8 V | 15.67% |
| **Suntech Power STP260-20/Wem** | 260.0 W | 237.4 W | 37.7 V | 30.9 V | 15.98% |
| **Suntech Power STP265-20/Wem** | 265.0 W | 242.1 W | 37.8 V | 31.0 V | 16.29% |
| **Suntech Power STP270-20/Wem** | 270.0 W | 246.8 W | 37.9 V | 31.1 V | 16.6% |

## How Many Suntech Power STP260-20/Wem Modules Fit in a Cold-Weather String?

Maximum series module counts for Suntech Power STP260-20/Wem from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.7V and beta_Voc=-0.341%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.49 V | 13 panels | 565.4 V | 22 panels |
| **-10 C (14 F)** | 42.2 V | 14 panels | 590.8 V | 23 panels |
| **0 C (32 F)** | 40.91 V | 14 panels | 572.7 V | 24 panels |
| **25 C (77 F STC)** | 37.7 V | 15 panels | 565.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP260-20/Wem?

Alternative CEC solar modules from competing brands near Suntech Power STP260-20/Wem (260.0 W), including AXITEC AC-260M/156-60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-260M/156-60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-260m-156-60s/) AXITEC | 260.0 W | Tie (0 W) | 37.73 V | 16.02% | 90.2% |
| [**AXITEC AC-260P/156-60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-260p-156-60s/) AXITEC | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| [**Centrosolar America EP6 260BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-260bw/) Centrosolar America | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| [**Centrosolar America EP6 260SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-260sw/) Centrosolar America | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP260-20/Wem?

Evaluate Suntech Power STP260-20/Wem (260.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP260-20/Wem reaches 43.49 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP260-20/Wem carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP260-20/Wem 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260M/156-60S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 237.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP260-20/Wem by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Suntech Power STP260-20/Wem PTC wattage (237.4 W) lower than STC (260.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 237.4 W PTC (91.3% retention) across Suntech Power STP260-20/Wem's 1.627 m2 aperture.

### Who should skip Suntech Power STP260-20/Wem on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Suntech Power STP260-20/Wem panels (543 sq ft) leave unusable roof gaps vs. AXITEC AC-260M/156-60S.

### What is the 1,000 V commercial string limit for Suntech Power STP260-20/Wem?

On 1,000 V commercial inverters at -10 C (42.2 V cold Voc), Suntech Power STP260-20/Wem fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Suntech Power STP260-20/Wem.

## Related Pages

Compare Suntech Power equipment, AXITEC AC-260M/156-60S specs, utility payback rates, and NEC string calculators alongside Suntech Power STP260-20/Wem.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)