# Suntech Power STP260-20/Wde — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP260-20/Wde is a 260.0 W STC (237.3 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 37.6 V Voc at 25 C, and 42.07 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 260.0 W

- **PTC Wattage** : 237.3 W

- **Voc @ 25C** : 37.6 V

- **Efficiency** : 15.98%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP260-20/Wde Compare Against Peer CEC Listings?

Engineering position of Suntech Power STP260-20/Wde (260.0 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJP260-60 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Suntech Power STP260-20/Wde pairs typical 91.3% PTC-to-STC thermal output (237.3 W real-world rating) with 37.6 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,356 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Anhui Rinengzhongtian Semiconductor Development QJP260-60 offers a 260.0 W alternative.

## Where Does Suntech Power STP260-20/Wde Fall Across Listed CEC Models?

Plots Suntech Power STP260-20/Wde at 260.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Suntech Power STP260-20/Wde?

Benchmarks Suntech Power STP260-20/Wde on STC wattage, thermal PTC/STC retention, and 15.98 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Suntech Power STP260-20/Wde?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Suntech Power STP260-20/Wde by Suntech Power.

Rank #19,146 / 21,677

### 260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

### 15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.07 V at -10 C (589.0 V string) and 43.35 V at -20 C (13 max).

 8 kW Reference Array

### 31 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,356 W PTC; NEC 690.8 OCPD floor is 13.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.6 * (1 + (-0.34/100) * (-10 - 25)) = 42.07 V | OCPD = 1.56 * 8.83 = 13.77 A

Inputs from CEC Modules.csv for Suntech Power STP260-20/Wde: Voc=37.6 V, beta_Voc=-0.34%/C, Isc=8.83 A, STC=260.0 W, Area=1.627 m2.

**Result:** 14 panels max on 600 V (589.0 V); 31 panels for 8 kW (543 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP260-20/Wde?

Laboratory test ratings recorded for Suntech Power STP260-20/Wde (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP260-20/Wde.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 237.3 W (91.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.1 V / 8.37 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.98% (1.627 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP260-20/Wde Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for Suntech Power STP260-20/Wde.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 31 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 39 | 10.14 kW | 683 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Sibling wattage bins and frame colors grouped with Suntech Power STP260-20/Wde under Suntech Power to prevent duplicate spec pages.

Sibling CEC listings grouped into the Suntech Power STP260-20/Wde wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP250-20/Wde** | 250.0 W | 228.0 W | 37.4 V | 30.7 V | 15.37% |
| **Suntech Power STP255-20/Wde** | 255.0 W | 232.7 W | 37.5 V | 30.9 V | 15.67% |
| **Suntech Power STP260-20/Wde** | 260.0 W | 237.3 W | 37.6 V | 31.1 V | 15.98% |
| **Suntech Power STP265-20/Wde** | 265.0 W | 242.0 W | 37.7 V | 31.3 V | 16.29% |

## How Many Suntech Power STP260-20/Wde Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Suntech Power STP260-20/Wde (beta_Voc -0.34%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.6V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.35 V | 13 panels | 563.6 V | 23 panels |
| **-10 C (14 F)** | 42.07 V | 14 panels | 589.0 V | 23 panels |
| **0 C (32 F)** | 40.8 V | 14 panels | 571.2 V | 24 panels |
| **25 C (77 F STC)** | 37.6 V | 15 panels | 564.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP260-20/Wde?

Closest cross-brand CEC competitors to Suntech Power STP260-20/Wde matched near 260.0 W STC and 37.6 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJP260-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJP260-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp260-60/) Anhui Rinengzhongtian Semiconductor Development | 260.0 W | Tie (0 W) | 37.64 V | 15.98% | 90.7% |
| [**AXITEC AC-260P/156-60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-260p-156-60s/) AXITEC | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| [**Centrosolar America EP6 260BW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-260bw/) Centrosolar America | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| [**Centrosolar America EP6 260SW**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-ep6-260sw/) Centrosolar America | 260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP260-20/Wde?

Evaluate Suntech Power STP260-20/Wde (260.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP260-20/Wde reaches 43.35 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP260-20/Wde carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP260-20/Wde 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP260-60.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 237.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP260-20/Wde by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Suntech Power STP260-20/Wde?

Multiplying Suntech Power STP260-20/Wde's 8.83 A short-circuit current by 1.56 equals 13.77 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Suntech Power STP260-20/Wde pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.07 V cold Voc at 14 F and handles 8.83 A Isc; string inverters cap Suntech Power STP260-20/Wde at 14 panels on 600 V.

### Is Suntech Power STP260-20/Wde eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP260-20/Wde rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare Suntech Power equipment, Anhui Rinengzhongtian Semiconductor Development QJP260-60 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP260-20/Wde.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)