# Suntech Power STP250S-20/Wd — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP250S-20/Wd is a 250.0 W STC (226.3 W PTC) Mono-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.37% efficiency, 37.4 V Voc at 25 C, and 42.65 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 250.0 W

- **PTC Wattage** : 226.3 W

- **Voc @ 25C** : 37.4 V

- **Efficiency** : 15.37%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP250S-20/Wd Compare Against Peer CEC Listings?

How Suntech Power Suntech Power STP250S-20/Wd handles rooftop heat (226.3 W PTC), 8 kW sizing, and cold winter string voltage.

Suntech Power builds the Suntech Power STP250S-20/Wd (Mono-c-Si) as a compact residential or specialty off-grid module delivering 153.7 W/m2 (4.54 percentage points below 19.91% CEC median). Compared against Anji Technology AJP-M660-250 (250.0 W), this model holds typical 90.5% PTC-to-STC thermal output (226.3 W real-world rating). Lower 37.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.46 A overcurrent floor served by a 15 A breaker.

## Where Does Suntech Power STP250S-20/Wd Fall Across Listed CEC Models?

Where Suntech Power STP250S-20/Wd (250.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Suntech Power STP250S-20/Wd?

Percentile placement of Suntech Power STP250S-20/Wd across power density (153.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Suntech Power STP250S-20/Wd?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP250S-20/Wd specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #19,686 / 21,677

### 250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,164

### 15.37% Aperture Efficiency

Power density 153.7 W/m2 (4.54 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.65 V at -10 C (597.1 V string) and 44.15 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,000 W STC

Occupies 52.1 m2 (560 sq ft) producing 7,242 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.4 * (1 + (-0.401/100) * (-10 - 25)) = 42.65 V | OCPD = 1.56 * 8.63 = 13.46 A

Inputs from CEC Modules.csv for Suntech Power STP250S-20/Wd: Voc=37.4 V, beta_Voc=-0.401%/C, Isc=8.63 A, STC=250.0 W, Area=1.627 m2.

**Result:** 14 panels max on 600 V (597.1 V); 32 panels for 8 kW (560 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP250S-20/Wd?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP250S-20/Wd.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP250S-20/Wd.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 250.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 226.3 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.7 V / 8.15 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.401 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.37% (1.627 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP250S-20/Wd Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP250S-20/Wd (250.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.0 kW | 420 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 32 | 8.0 kW | 560 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 40 | 10.0 kW | 701 sq ft | $2,503 | $4,232 |

## How Many Suntech Power STP250S-20/Wd Modules Fit in a Cold-Weather String?

Maximum series module counts for Suntech Power STP250S-20/Wd from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.4V and beta_Voc=-0.401%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.15 V | 13 panels | 573.9 V | 22 panels |
| **-10 C (14 F)** | 42.65 V | 14 panels | 597.1 V | 23 panels |
| **0 C (32 F)** | 41.15 V | 14 panels | 576.1 V | 24 panels |
| **25 C (77 F STC)** | 37.4 V | 16 panels | 598.4 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP250S-20/Wd?

Alternative CEC solar modules from competing brands near Suntech Power STP250S-20/Wd (250.0 W), including Anji Technology AJP-M660-250.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anji Technology AJP-M660-250**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-250/) Anji Technology | 250.0 W | Tie (0 W) | 37.32 V | 15.4% | 89.0% |
| [**Boviet Solar Technology Co Ltd BVM6610P-250**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610p-250/) Boviet Solar Technology Co Ltd | 250.0 W | Tie (0 W) | 37.5 V | 15.37% | 90.2% |
| [**Eoplly New Energy Technology EP156MB/60-250S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-250s-ac/) Eoplly New Energy Technology | 250.0 W | Tie (0 W) | 37.26 V | 15.45% | 89.6% |
| [**Changzhou Nesl Solartech DJ-250DA/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-250da-c-st15/) Changzhou Nesl Solartech | 250.0 W | Tie (0 W) | 38.07 V | 15.3% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP250S-20/Wd?

Evaluate Suntech Power STP250S-20/Wd (250.0 W STC, 37.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP250S-20/Wd reaches 44.15 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (560 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP250S-20/Wd carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP250S-20/Wd 8 kW Residential Fit

Needs 32 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anji Technology AJP-M660-250.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP250S-20/Wd by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Suntech Power STP250S-20/Wd?

Multiplying Suntech Power STP250S-20/Wd's 8.63 A short-circuit current by 1.56 equals 13.46 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Suntech Power STP250S-20/Wd pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.65 V cold Voc at 14 F and handles 8.63 A Isc; string inverters cap Suntech Power STP250S-20/Wd at 14 panels on 600 V.

### Is Suntech Power STP250S-20/Wd eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP250S-20/Wd rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

## Related Pages

Compare Suntech Power equipment, Anji Technology AJP-M660-250 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP250S-20/Wd.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)