title: "Suntech Power STP235-20/Wd Specs (235.0W, 37.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp235-20-wd/
description: "CEC datasheet for Suntech Power STP235-20/Wd: 235.0W STC, 37.0V Voc, 35-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Suntech Power STP235-20/Wd — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP235-20/Wd is a 235.0 W STC (213.9 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.24% efficiency, 37.0 V Voc at 25 C, and 41.4 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 235.0 W

- **PTC Wattage** : 213.9 W

- **Voc @ 25C** : 37.0 V

- **Efficiency** : 14.24%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP235-20/Wd Compare Against Peer CEC Listings?

How Suntech Power Suntech Power STP235-20/Wd handles rooftop heat (213.9 W PTC), 8 kW sizing, and cold winter string voltage.

Suntech Power builds the Suntech Power STP235-20/Wd (Multi-c-Si) as a compact residential or specialty off-grid module delivering 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). Compared against Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q (235.0 W), this model holds typical 91.0% PTC-to-STC thermal output (213.9 W real-world rating). Lower 37.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.03 A overcurrent floor served by a 15 A breaker.

## Where Does Suntech Power STP235-20/Wd Fall Across Listed CEC Models?

Where Suntech Power STP235-20/Wd (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Suntech Power STP235-20/Wd?

Percentile placement of Suntech Power STP235-20/Wd across power density (142.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Suntech Power STP235-20/Wd?

Four critical engineering numbers homeowners and solar installers check first when reviewing Suntech Power STP235-20/Wd specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #20,368 / 21,677

### 235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,657

### 14.24% Aperture Efficiency

Power density 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.4 V at -10 C (579.6 V string) and 42.66 V at -20 C (14 max).

 8 kW Reference Array

### 35 Panels = 8,225 W STC

Occupies 57.8 m2 (622 sq ft) producing 7,486 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.0 * (1 + (-0.34/100) * (-10 - 25)) = 41.4 V | OCPD = 1.56 * 8.35 = 13.03 A

Inputs from CEC Modules.csv for Suntech Power STP235-20/Wd: Voc=37.0 V, beta_Voc=-0.34%/C, Isc=8.35 A, STC=235.0 W, Area=1.65 m2.

**Result:** 14 panels max on 600 V (579.6 V); 35 panels for 8 kW (622 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP235-20/Wd?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Suntech Power STP235-20/Wd.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP235-20/Wd.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 213.9 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.2 V / 7.79 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.34 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.24% (1.65 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP235-20/Wd Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Suntech Power STP235-20/Wd (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.11 kW | 462 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 35 | 8.22 kW | 622 sq ft | $2,057 | $3,479 |
| **10 kW Class** | 43 | 10.11 kW | 764 sq ft | $2,530 | $4,279 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

All closely matched Suntech Power wattages and cosmetic trims sharing the Suntech Power STP235-20/Wd architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Suntech Power STP235-20/Wd wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP225-20/Wd** | 225.0 W | 203.9 W | 36.7 V | 29.6 V | 13.64% |
| **Suntech Power STP230-20/Wd** | 230.0 W | 208.6 W | 36.8 V | 29.8 V | 13.94% |
| **Suntech Power STP235-20/Wd** | 235.0 W | 213.9 W | 37.0 V | 30.2 V | 14.24% |
| **Suntech Power STP240-20/Wd** | 240.0 W | 218.6 W | 37.2 V | 30.2 V | 14.55% |
| **Suntech Power STP245-20/Wd** | 245.0 W | 223.3 W | 37.3 V | 30.5 V | 15.06% |

## How Many Suntech Power STP235-20/Wd Modules Fit in a Cold-Weather String?

Maximum series module counts for Suntech Power STP235-20/Wd from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.0V and beta_Voc=-0.34%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.66 V | 14 panels | 597.2 V | 23 panels |
| **-10 C (14 F)** | 41.4 V | 14 panels | 579.6 V | 24 panels |
| **0 C (32 F)** | 40.14 V | 14 panels | 562.0 V | 24 panels |
| **25 C (77 F STC)** | 37.0 V | 16 panels | 592.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP235-20/Wd?

Alternative CEC solar modules from competing brands near Suntech Power STP235-20/Wd (235.0 W), including Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-3-235q/) Hanwha Qcells (Qidong) Co Ltd | 235.0 W | Tie (0 W) | 37.0 V | 14.54% | 89.0% |
| [**Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-hsl60p6-pb-3-235qw/) Hanwha Qcells (Qidong) Co Ltd | 235.0 W | Tie (0 W) | 37.0 V | 14.54% | 89.0% |
| [**Centrosolar America DP60 235**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-235/) Centrosolar America | 235.0 W | Tie (0 W) | 36.98 V | 14.33% | 90.0% |
| [**CSI Solar Co Ltd CS6P-235P**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-235p/) CSI Solar Co Ltd | 235.0 W | Tie (0 W) | 36.9 V | 15.17% | 90.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP235-20/Wd?

Evaluate Suntech Power STP235-20/Wd (235.0 W STC, 37.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP235-20/Wd reaches 42.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP235-20/Wd carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP235-20/Wd 8 kW Residential Fit

Needs 35 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP235-20/Wd by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Suntech Power STP235-20/Wd?

Multiplying Suntech Power STP235-20/Wd's 8.35 A short-circuit current by 1.56 equals 13.03 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Suntech Power STP235-20/Wd pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.4 V cold Voc at 14 F and handles 8.35 A Isc; string inverters cap Suntech Power STP235-20/Wd at 14 panels on 600 V.

### Is Suntech Power STP235-20/Wd eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP235-20/Wd rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

## Related Pages

Compare Suntech Power equipment, Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q specs, utility payback rates, and NEC string calculators alongside Suntech Power STP235-20/Wd.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)