title: "Suntech Power STP215-20/Wd Specs (215.0W, 36.5V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp215-20-wd/
description: "CEC datasheet for Suntech Power STP215-20/Wd: 215.0W STC, 36.5V Voc, 38-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Suntech Power STP215-20/Wd — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP215-20/Wd is a 215.0 W STC (194.7 W PTC) Multi-c-Si solar module ranking #20,859 of 21,677 CEC listings (below all-CEC median; higher than 3.5% of peers). It delivers 13.03% efficiency, 36.5 V Voc at 25 C, and 40.49 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 215.0 W

- **PTC Wattage** : 194.7 W

- **Voc @ 25C** : 36.5 V

- **Efficiency** : 13.03%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP215-20/Wd Compare Against Peer CEC Listings?

Solar engineering breakdown for Suntech Power STP215-20/Wd: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Suntech Power and peers, Suntech Power STP215-20/Wd stands 63.8 W below the 278.8 W Multi-c-Si median and typical 90.6% PTC-to-STC thermal output (194.7 W real-world rating). Sizing 6 kW (28 panels) to 10 kW (47 panels) yields $1,507-$2,530/yr in baseline US bill offset. Lower 36.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Suntech Power STP215-20/Wd Fall Across Listed CEC Models?

Distribution marker showing Suntech Power STP215-20/Wd (215.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Suntech Power STP215-20/Wd?

Dataset percentiles tracking Suntech Power STP215-20/Wd power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Suntech Power STP215-20/Wd?

Benchmark highlights for Suntech Power STP215-20/Wd covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,859 / 21,677

### 215.0 W STC · Higher Than 3.5%

215.0 W STC (-170.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,400

### 13.03% Aperture Efficiency

Power density 130.3 W/m2 (6.88 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.49 V at -10 C (566.9 V string) and 41.62 V at -20 C (14 max).

 8 kW Reference Array

### 38 Panels = 8,170 W STC

Occupies 62.7 m2 (675 sq ft) producing 7,399 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.5 * (1 + (-0.312/100) * (-10 - 25)) = 40.49 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Suntech Power STP215-20/Wd: Voc=36.5 V, beta_Voc=-0.312%/C, Isc=7.95 A, STC=215.0 W, Area=1.65 m2.

**Result:** 14 panels max on 600 V (566.9 V); 38 panels for 8 kW (675 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP215-20/Wd?

Official CEC datasheet figures for Suntech Power STP215-20/Wd (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP215-20/Wd.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 215.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 194.7 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.2 V / 7.37 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.312 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.03% (1.65 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP215-20/Wd Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Suntech Power STP215-20/Wd modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 28 | 6.02 kW | 497 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 38 | 8.17 kW | 675 sq ft | $2,045 | $3,458 |
| **10 kW Class** | 47 | 10.11 kW | 835 sq ft | $2,530 | $4,279 |

## Which Sibling Wattage & Trim Variants Belong to This Suntech Power Series?

Consolidated Suntech Power wattage variants sharing the Suntech Power STP215-20/Wd mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Suntech Power STP215-20/Wd wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Suntech Power STP210-20/Wd** | 210.0 W | 190.0 W | 36.4 V | 29.0 V | 12.73% |
| **Suntech Power STP215-20/Wd** | 215.0 W | 194.7 W | 36.5 V | 29.2 V | 13.03% |
| **Suntech Power STP220-20/Wd** | 220.0 W | 199.3 W | 36.6 V | 29.5 V | 13.33% |

## How Many Suntech Power STP215-20/Wd Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Suntech Power STP215-20/Wd (40.49 V at 14 F).

Computed from Voc=36.5V and beta_Voc=-0.312%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.62 V | 14 panels | 582.7 V | 24 panels |
| **-10 C (14 F)** | 40.49 V | 14 panels | 566.9 V | 24 panels |
| **0 C (32 F)** | 39.35 V | 15 panels | 590.2 V | 25 panels |
| **25 C (77 F STC)** | 36.5 V | 16 panels | 584.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP215-20/Wd?

Competing CEC solar panels closest to Suntech Power STP215-20/Wd in nameplate wattage and Voc, starting with Anji Dasol Solar Energy Science & Technology DS-A4-215.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anji Dasol Solar Energy Science & Technology DS-A4-215**](https://epri-peac.com/solar-equipment/modules/anji-dasol-solar-energy-science-technology/anji-dasol-solar-energy-science-technology-ds-a4-215/) Anji Dasol Solar Energy Science & Technology | 215.0 W | Tie (0 W) | 36.3 V | 13.06% | 87.1% |
| [**APOS Energy AP215**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-ap215/) APOS Energy | 215.0 W | Tie (0 W) | 36.79 V | 12.96% | 88.8% |
| [**CSI Solar Co Ltd CS6P-215M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-215m/) CSI Solar Co Ltd | 215.0 W | Tie (0 W) | 36.8 V | 13.88% | 90.2% |
| [**Advance Power API-P215**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p215/) Advance Power | 215.0 W | Tie (0 W) | 36.0 V | 13.13% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP215-20/Wd?

Evaluate Suntech Power STP215-20/Wd (215.0 W STC, 36.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP215-20/Wd reaches 41.62 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 38 panels for an 8 kW build require 675 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 38 panels (675 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP215-20/Wd carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP215-20/Wd 8 kW Residential Fit

Needs 38 modules (675 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anji Dasol Solar Energy Science & Technology DS-A4-215.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 194.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP215-20/Wd by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Suntech Power STP215-20/Wd?

Multiplying Suntech Power STP215-20/Wd's 7.95 A short-circuit current by 1.56 equals 12.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Suntech Power STP215-20/Wd pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.49 V cold Voc at 14 F and handles 7.95 A Isc; string inverters cap Suntech Power STP215-20/Wd at 14 panels on 600 V.

### Is Suntech Power STP215-20/Wd eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Suntech Power STP215-20/Wd rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

## Related Pages

Compare Suntech Power equipment, Anji Dasol Solar Energy Science & Technology DS-A4-215 specs, utility payback rates, and NEC string calculators alongside Suntech Power STP215-20/Wd.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)