title: "Suntech Power STP170S-24/Adb+ Specs (170.0W, 43.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp170s-24-adb/
description: "CEC datasheet for Suntech Power STP170S-24/Adb+: 170.0W STC, 43.8V Voc, 48-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Suntech Power STP170S-24/Adb+ — CEC Solar Module Specifications

Manufacturer: [**Suntech Power**](https://epri-peac.com/solar-equipment/brands/suntech-power/) Registry: **CEC Verified Engineering Specification**

Suntech Power STP170S-24/Adb+ is a 170.0 W STC (152.9 W PTC) Mono-c-Si solar module ranking #21,323 of 21,677 CEC listings (below all-CEC median; higher than 1.5% of peers). It delivers 13.32% efficiency, 43.8 V Voc at 25 C, and 48.74 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 170.0 W

- **PTC Wattage** : 152.9 W

- **Voc @ 25C** : 43.8 V

- **Efficiency** : 13.32%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Suntech Power STP170S-24/Adb+ Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Suntech Power STP170S-24/Adb+ (Mono-c-Si) residential solar systems.

Homeowners evaluating Suntech Power STP170S-24/Adb+ need 36 panels for 6 kW or 48 panels (660 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (660 sq ft). Under NEC 690.7(A), beta_Voc (-0.322%/C) pushes open-circuit voltage to 48.74 V at 14 F and 50.15 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Suntech Power STP170S-24/Adb+ Fall Across Listed CEC Models?

Comparison of Suntech Power STP170S-24/Adb+ (170.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Suntech Power STP170S-24/Adb+?

Relative ranking of Suntech Power STP170S-24/Adb+ across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Suntech Power STP170S-24/Adb+?

Summary of Suntech Power STP170S-24/Adb+ output rank, 8 kW array size (48 panels), efficiency rating, and 600 V string limit.

Rank #21,323 / 21,677

### 170.0 W STC · Higher Than 1.5%

170.0 W STC (-215.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,302

### 13.32% Aperture Efficiency

Power density 133.1 W/m2 (6.59 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.74 V at -10 C (584.9 V string) and 50.15 V at -20 C (11 max).

 8 kW Reference Array

### 48 Panels = 8,160 W STC

Occupies 61.3 m2 (660 sq ft) producing 7,339 W PTC; NEC 690.8 OCPD floor is 8.02 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.8 * (1 + (-0.322/100) * (-10 - 25)) = 48.74 V | OCPD = 1.56 * 5.14 = 8.02 A

Inputs from CEC Modules.csv for Suntech Power STP170S-24/Adb+: Voc=43.8 V, beta_Voc=-0.322%/C, Isc=5.14 A, STC=170.0 W, Area=1.277 m2.

**Result:** 12 panels max on 600 V (584.9 V); 48 panels for 8 kW (660 sq ft).

## What Are the Published CEC Specifications for Suntech Power STP170S-24/Adb+?

Complete CEC test sheet for Suntech Power STP170S-24/Adb+ including Isc (5.14 A), Voc (43.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Suntech Power STP170S-24/Adb+.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 170.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 152.9 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.2 V / 4.83 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.322 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.32% (1.277 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Suntech Power STP170S-24/Adb+ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Suntech Power STP170S-24/Adb+.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 36 | 6.12 kW | 495 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 48 | 8.16 kW | 660 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 59 | 10.03 kW | 811 sq ft | $2,510 | $4,245 |

## How Many Suntech Power STP170S-24/Adb+ Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Suntech Power STP170S-24/Adb+ (43.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.8V and beta_Voc=-0.322%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.15 V | 11 panels | 551.6 V | 19 panels |
| **-10 C (14 F)** | 48.74 V | 12 panels | 584.9 V | 20 panels |
| **0 C (32 F)** | 47.33 V | 12 panels | 568.0 V | 21 panels |
| **25 C (77 F STC)** | 43.8 V | 13 panels | 569.4 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Suntech Power STP170S-24/Adb+?

Four comparable CEC modules such as Jiangyin Hareon Power HR-170W/24V (170.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Jiangyin Hareon Power HR-170W/24V**](https://epri-peac.com/solar-equipment/modules/jiangyin-hareon-power/jiangyin-hareon-power-hr-170w-24v/) Jiangyin Hareon Power | 170.0 W | Tie (0 W) | 43.8 V | 13.32% | 89.8% |
| [**Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170**](https://epri-peac.com/solar-equipment/modules/jinzhou-jinmao-photovoltaic-technology/jinzhou-jinmao-photovoltaic-technology-jmpv-5m-72-170/) Jinzhou Jinmao Photovoltaic Technology | 170.0 W | Tie (0 W) | 43.75 V | 13.32% | 86.4% |
| [**Trina Solar TSM-170DA01**](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-170da01/) Trina Solar | 170.0 W | Tie (0 W) | 43.6 V | 13.47% | 90.5% |
| [**Hanwha Qcells (Qidong) Co Ltd SF160-24-P170**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf160-24-p170/) Hanwha Qcells (Qidong) Co Ltd | 170.0 W | Tie (0 W) | 44.1 V | 13.32% | 88.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Suntech Power STP170S-24/Adb+?

Evaluate Suntech Power STP170S-24/Adb+ (170.0 W STC, 43.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Suntech Power STP170S-24/Adb+ reaches 50.15 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 48 panels for an 8 kW build require 660 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 48 panels (660 sq ft).
- 2026 tax credit baseline: cash residential installs of Suntech Power STP170S-24/Adb+ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Suntech Power STP170S-24/Adb+ 8 kW Residential Fit

Needs 48 modules (660 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Jiangyin Hareon Power HR-170W/24V.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 152.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Suntech Power STP170S-24/Adb+ by Suntech Power grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Suntech Power STP170S-24/Adb+ PTC wattage (152.9 W) lower than STC (170.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 152.9 W PTC (89.9% retention) across Suntech Power STP170S-24/Adb+'s 1.277 m2 aperture.

### Who should skip Suntech Power STP170S-24/Adb+ on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 48 Suntech Power STP170S-24/Adb+ panels (660 sq ft) leave unusable roof gaps vs. Jiangyin Hareon Power HR-170W/24V.

### What is the 1,000 V commercial string limit for Suntech Power STP170S-24/Adb+?

On 1,000 V commercial inverters at -10 C (48.74 V cold Voc), Suntech Power STP170S-24/Adb+ fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Suntech Power STP170S-24/Adb+.

## Related Pages

Compare Suntech Power equipment, Jiangyin Hareon Power HR-170W/24V specs, utility payback rates, and NEC string calculators alongside Suntech Power STP170S-24/Adb+.

[All Suntech Power Certified Solar Models](https://epri-peac.com/solar-equipment/brands/suntech-power/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Suntech Power

- [All Suntech Power Specs](https://epri-peac.com/solar-equipment/brands/suntech-power/)
- [Suntech Power STP330-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp330-24-vem/)
- [Suntech Power STP315-24/Vem](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp315-24-vem/)
- [Suntech Power STP310-24/Vd](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vd/)
- [Suntech Power STP310-24/Vdx](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-vdx/)
- [Suntech Power STP310-24/Ve](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp310-24-ve/)