title: "SunSpark Technology Inc Specs (385.0W, 48.97V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-385m3-72/
description: "CEC datasheet for SunSpark Technology Inc SST-385M3-72: 385.0W STC, 48.97V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# SunSpark Technology Inc SST-385M3-72 — CEC Solar Module Specifications

Manufacturer: [**SunSpark Technology Inc**](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/) Registry: **CEC Verified Engineering Specification**

SunSpark Technology Inc SST-385M3-72 is a 385.0 W STC (358.8 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.54% efficiency, 48.97 V Voc at 25 C, and 52.95 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 358.8 W

- **Voc @ 25C** : 48.97 V

- **Efficiency** : 19.54%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SunSpark Technology Inc SST-385M3-72 Compare Against Peer CEC Listings?

How SunSpark Technology Inc SunSpark Technology Inc SST-385M3-72 handles rooftop heat (358.8 W PTC), 8 kW sizing, and cold winter string voltage.

SunSpark Technology Inc builds the SunSpark Technology Inc SST-385M3-72 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 195.4 W/m2 (0.37 percentage points below 19.91% CEC median). Compared against EMMVEE Photovoltaic Power Private Limited E385M72 (385.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 48.97 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.79 A overcurrent floor served by a 20 A breaker.

## Where Does SunSpark Technology Inc SST-385M3-72 Fall Across Listed CEC Models?

Where SunSpark Technology Inc SST-385M3-72 (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SunSpark Technology Inc SST-385M3-72?

Percentile placement of SunSpark Technology Inc SST-385M3-72 across power density (195.4 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SunSpark Technology Inc SST-385M3-72?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunSpark Technology Inc SST-385M3-72 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,046

### 19.54% Aperture Efficiency

Power density 195.4 W/m2 (0.37 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.95 V at -10 C (582.5 V string) and 54.08 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 41.4 m2 (445 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 15.79 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.97 * (1 + (-0.232/100) * (-10 - 25)) = 52.95 V | OCPD = 1.56 * 10.12 = 15.79 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-385M3-72: Voc=48.97 V, beta_Voc=-0.232%/C, Isc=10.12 A, STC=385.0 W, Area=1.97 m2.

**Result:** 11 panels max on 600 V (582.5 V); 21 panels for 8 kW (445 sq ft).

## What Are the Published CEC Specifications for SunSpark Technology Inc SST-385M3-72?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunSpark Technology Inc SST-385M3-72.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-385M3-72.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 358.8 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 48.97 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.12 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.28 V / 9.57 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.232 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.54% (1.97 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SunSpark Technology Inc SST-385M3-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunSpark Technology Inc SST-385M3-72 (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 339 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 445 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 551 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

All closely matched SunSpark Technology Inc wattages and cosmetic trims sharing the SunSpark Technology Inc SST-385M3-72 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the SunSpark Technology Inc SST-385M3-72 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SunSpark Technology Inc SST-375M3-72** | 375.0 W | 349.2 W | 48.44 V | 39.74 V | 19.04% |
| **SunSpark Technology Inc SST-380M3-72** | 380.0 W | 354.0 W | 48.7 V | 40.02 V | 19.29% |
| **SunSpark Technology Inc SST-385M3-72** | 385.0 W | 358.8 W | 48.97 V | 40.28 V | 19.54% |
| **SunSpark Technology Inc SST-390M3-72** | 390.0 W | 363.6 W | 49.27 V | 40.6 V | 19.8% |
| **SunSpark Technology Inc SST-395M3-72** | 395.0 W | 368.3 W | 49.56 V | 40.89 V | 20.05% |

## How Many SunSpark Technology Inc SST-385M3-72 Modules Fit in a Cold-Weather String?

Maximum series module counts for SunSpark Technology Inc SST-385M3-72 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.97V and beta_Voc=-0.232%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.08 V | 11 panels | 594.9 V | 18 panels |
| **-10 C (14 F)** | 52.95 V | 11 panels | 582.5 V | 18 panels |
| **0 C (32 F)** | 51.81 V | 11 panels | 569.9 V | 19 panels |
| **25 C (77 F STC)** | 48.97 V | 12 panels | 587.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-385M3-72?

Alternative CEC solar modules from competing brands near SunSpark Technology Inc SST-385M3-72 (385.0 W), including EMMVEE Photovoltaic Power Private Limited E385M72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**EMMVEE Photovoltaic Power Private Limited E385M72**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e385m72/) EMMVEE Photovoltaic Power Private Limited | 385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-W5-385-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-w5-385-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h/) Boviet Solar Technology Co Ltd | 385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-385M3-72?

Evaluate SunSpark Technology Inc SST-385M3-72 (385.0 W STC, 48.97 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-385M3-72 reaches 54.08 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-385M3-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SunSpark Technology Inc SST-385M3-72 8 kW Residential Fit

Needs 21 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-385M3-72 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SunSpark Technology Inc SST-385M3-72?

Multiplying SunSpark Technology Inc SST-385M3-72's 10.12 A short-circuit current by 1.56 equals 15.79 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can SunSpark Technology Inc SST-385M3-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.95 V cold Voc at 14 F and handles 10.12 A Isc; string inverters cap SunSpark Technology Inc SST-385M3-72 at 11 panels on 600 V.

### Is SunSpark Technology Inc SST-385M3-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunSpark Technology Inc SST-385M3-72 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

## Related Pages

Compare SunSpark Technology Inc equipment, EMMVEE Photovoltaic Power Private Limited E385M72 specs, utility payback rates, and NEC string calculators alongside SunSpark Technology Inc SST-385M3-72.

[All SunSpark Technology Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SunSpark Technology Inc

- [All SunSpark Technology Inc Specs](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/)
- [SunSpark Technology Inc SST-M156(HCBF)-600W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-600w/)
- [SunSpark Technology Inc SST-M156(HCBF)-590W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-590w/)
- [SunSpark Technology Inc SST-M156(HCBF)-570W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-570w/)
- [SunSpark Technology Inc SG7G72M(H)-555](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sg7g72m-h-555/)
- [SunSpark Technology Inc SST-M144(HCBF)-555W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m144-hcbf-555w/)