CEC PV Module

# SunSpark Technology Inc SST-315M3B-60 — CEC Solar Module Specifications

Manufacturer: [**SunSpark Technology Inc**](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/) Registry: **CEC Verified Engineering Specification**

SunSpark Technology Inc SST-315M3B-60 is a 315.0 W STC (288.1 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 19.09% efficiency, 40.53 V Voc at 25 C, and 44.02 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 315.0 W

- **PTC Wattage** : 288.1 W

- **Voc @ 25C** : 40.53 V

- **Efficiency** : 19.09%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SunSpark Technology Inc SST-315M3B-60 Compare Against Peer CEC Listings?

How SunSpark Technology Inc SunSpark Technology Inc SST-315M3B-60 handles rooftop heat (288.1 W PTC), 8 kW sizing, and cold winter string voltage.

SunSpark Technology Inc builds the SunSpark Technology Inc SST-315M3B-60 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 190.9 W/m2 (0.82 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60315 (315.0 W), this model holds strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Mid-range 40.53 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.77 A overcurrent floor served by a 20 A breaker.

## Where Does SunSpark Technology Inc SST-315M3B-60 Fall Across Listed CEC Models?

Where SunSpark Technology Inc SST-315M3B-60 (315.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SunSpark Technology Inc SST-315M3B-60?

Percentile placement of SunSpark Technology Inc SST-315M3B-60 across power density (190.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SunSpark Technology Inc SST-315M3B-60?

Four critical engineering numbers homeowners and solar installers check first when reviewing SunSpark Technology Inc SST-315M3B-60 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #15,387 / 21,677

### 315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,232

### 19.09% Aperture Efficiency

Power density 190.9 W/m2 (0.82 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.02 V at -10 C (572.3 V string) and 45.02 V at -20 C (13 max).

 8 kW Reference Array

### 26 Panels = 8,190 W STC

Occupies 42.9 m2 (462 sq ft) producing 7,491 W PTC; NEC 690.8 OCPD floor is 15.77 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.53 * (1 + (-0.246/100) * (-10 - 25)) = 44.02 V | OCPD = 1.56 * 10.11 = 15.77 A

Inputs from CEC Modules.csv for SunSpark Technology Inc SST-315M3B-60: Voc=40.53 V, beta_Voc=-0.246%/C, Isc=10.11 A, STC=315.0 W, Area=1.65 m2.

**Result:** 13 panels max on 600 V (572.3 V); 26 panels for 8 kW (462 sq ft).

## What Are the Published CEC Specifications for SunSpark Technology Inc SST-315M3B-60?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SunSpark Technology Inc SST-315M3B-60.

Official California Energy Commission (NREL SAM) test parameters for SunSpark Technology Inc SST-315M3B-60.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 288.1 W (91.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.53 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.11 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.9 V / 9.58 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.246 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.09% (1.65 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SunSpark Technology Inc SST-315M3B-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SunSpark Technology Inc SST-315M3B-60 (315.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.3 kW | 355 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 26 | 8.19 kW | 462 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 32 | 10.08 kW | 568 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This SunSpark Technology Inc Series?

All closely matched SunSpark Technology Inc wattages and cosmetic trims sharing the SunSpark Technology Inc SST-315M3B-60 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the SunSpark Technology Inc SST-315M3B-60 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SunSpark Technology Inc SST-310M3B-60** | 310.0 W | 283.4 W | 40.3 V | 32.61 V | 18.79% |
| **SunSpark Technology Inc SST-315M3B-60** | 315.0 W | 288.1 W | 40.53 V | 32.9 V | 19.09% |
| **SunSpark Technology Inc SST-320M3B-60** | 320.0 W | 292.8 W | 40.78 V | 33.18 V | 19.39% |

## How Many SunSpark Technology Inc SST-315M3B-60 Modules Fit in a Cold-Weather String?

Maximum series module counts for SunSpark Technology Inc SST-315M3B-60 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.53V and beta_Voc=-0.246%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.02 V | 13 panels | 585.3 V | 22 panels |
| **-10 C (14 F)** | 44.02 V | 13 panels | 572.3 V | 22 panels |
| **0 C (32 F)** | 43.02 V | 13 panels | 559.3 V | 23 panels |
| **25 C (77 F STC)** | 40.53 V | 14 panels | 567.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to SunSpark Technology Inc SST-315M3B-60?

Alternative CEC solar modules from competing brands near SunSpark Technology Inc SST-315M3B-60 (315.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60315.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/60315**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60315/) GCL System Integration Technology Co Ltd | 315.0 W | Tie (0 W) | 40.1 V | 19.33% | 91.3% |
| [**AXITEC AC-315MH/120S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120s/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**AXITEC AC-315MH/120V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-315mh-120v/) AXITEC | 315.0 W | Tie (0 W) | 39.74 V | 18.96% | 93.0% |
| [**CertainTeed CT315HC11-04**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ct315hc11-04/) CertainTeed | 315.0 W | Tie (0 W) | 39.74 V | 19.58% | 92.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SunSpark Technology Inc SST-315M3B-60?

Evaluate SunSpark Technology Inc SST-315M3B-60 (315.0 W STC, 40.53 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SunSpark Technology Inc SST-315M3B-60 reaches 45.02 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 462 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (462 sq ft).
- 2026 tax credit baseline: cash residential installs of SunSpark Technology Inc SST-315M3B-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SunSpark Technology Inc SST-315M3B-60 8 kW Residential Fit

Needs 26 modules (462 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60315.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.1 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunSpark Technology Inc SST-315M3B-60 by SunSpark Technology Inc grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SunSpark Technology Inc SST-315M3B-60?

Multiplying SunSpark Technology Inc SST-315M3B-60's 10.11 A short-circuit current by 1.56 equals 15.77 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can SunSpark Technology Inc SST-315M3B-60 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.02 V cold Voc at 14 F and handles 10.11 A Isc; string inverters cap SunSpark Technology Inc SST-315M3B-60 at 13 panels on 600 V.

### Is SunSpark Technology Inc SST-315M3B-60 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SunSpark Technology Inc SST-315M3B-60 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare SunSpark Technology Inc equipment, GCL System Integration Technology Co Ltd GCL-M6/60315 specs, utility payback rates, and NEC string calculators alongside SunSpark Technology Inc SST-315M3B-60.

[All SunSpark Technology Inc Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SunSpark Technology Inc

- [All SunSpark Technology Inc Specs](https://epri-peac.com/solar-equipment/brands/sunspark-technology-inc/)
- [SunSpark Technology Inc SST-M156(HCBF)-600W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-600w/)
- [SunSpark Technology Inc SST-M156(HCBF)-590W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-590w/)
- [SunSpark Technology Inc SST-M156(HCBF)-570W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m156-hcbf-570w/)
- [SunSpark Technology Inc SG7G72M(H)-555](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sg7g72m-h-555/)
- [SunSpark Technology Inc SST-M144(HCBF)-555W](https://epri-peac.com/solar-equipment/modules/sunspark-technology-inc/sunspark-technology-inc-sst-m144-hcbf-555w/)