title: "Sunrise Solartech SR-P672295 Specs (295.0W, 43.77V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672295/
description: "CEC datasheet for Sunrise Solartech SR-P672295: 295.0W STC, 43.77V Voc, 28-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Sunrise Solartech SR-P672295 — CEC Solar Module Specifications

Manufacturer: [**Sunrise Solartech**](https://epri-peac.com/solar-equipment/brands/sunrise-solartech/) Registry: **CEC Verified Engineering Specification**

Sunrise Solartech SR-P672295 is a 295.0 W STC (262.4 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.19% efficiency, 43.77 V Voc at 25 C, and 49.27 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 295.0 W

- **PTC Wattage** : 262.4 W

- **Voc @ 25C** : 43.77 V

- **Efficiency** : 15.19%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sunrise Solartech SR-P672295 Compare Against Peer CEC Listings?

How Sunrise Solartech Sunrise Solartech SR-P672295 handles rooftop heat (262.4 W PTC), 8 kW sizing, and cold winter string voltage.

Sunrise Solartech builds the Sunrise Solartech SR-P672295 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 151.9 W/m2 (4.72 percentage points below 19.91% CEC median). Compared against Chinaland Solar Energy HSE295-72P (295.0 W), this model holds typical 88.9% PTC-to-STC thermal output (262.4 W real-world rating). Mid-range 43.77 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.96 A overcurrent floor served by a 15 A breaker.

## Where Does Sunrise Solartech SR-P672295 Fall Across Listed CEC Models?

Where Sunrise Solartech SR-P672295 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Sunrise Solartech SR-P672295?

Percentile placement of Sunrise Solartech SR-P672295 across power density (151.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Sunrise Solartech SR-P672295?

Four critical engineering numbers homeowners and solar installers check first when reviewing Sunrise Solartech SR-P672295 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #16,890 / 21,677

### 295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,472

### 15.19% Aperture Efficiency

Power density 151.9 W/m2 (4.72 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.27 V at -10 C (591.2 V string) and 50.84 V at -20 C (11 max).

 8 kW Reference Array

### 28 Panels = 8,260 W STC

Occupies 54.4 m2 (585 sq ft) producing 7,347 W PTC; NEC 690.8 OCPD floor is 13.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.77 * (1 + (-0.359/100) * (-10 - 25)) = 49.27 V | OCPD = 1.56 * 8.95 = 13.96 A

Inputs from CEC Modules.csv for Sunrise Solartech SR-P672295: Voc=43.77 V, beta_Voc=-0.359%/C, Isc=8.95 A, STC=295.0 W, Area=1.942 m2.

**Result:** 12 panels max on 600 V (591.2 V); 28 panels for 8 kW (585 sq ft).

## What Are the Published CEC Specifications for Sunrise Solartech SR-P672295?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sunrise Solartech SR-P672295.

Official California Energy Commission (NREL SAM) test parameters for Sunrise Solartech SR-P672295.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 262.4 W (88.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.77 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.3 V / 8.36 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.19% (1.942 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Sunrise Solartech SR-P672295 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sunrise Solartech SR-P672295 (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 21 | 6.2 kW | 439 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 28 | 8.26 kW | 585 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 34 | 10.03 kW | 711 sq ft | $2,510 | $4,245 |

## How Many Sunrise Solartech SR-P672295 Modules Fit in a Cold-Weather String?

Maximum series module counts for Sunrise Solartech SR-P672295 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.77V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.84 V | 11 panels | 559.2 V | 19 panels |
| **-10 C (14 F)** | 49.27 V | 12 panels | 591.2 V | 20 panels |
| **0 C (32 F)** | 47.7 V | 12 panels | 572.4 V | 20 panels |
| **25 C (77 F STC)** | 43.77 V | 13 panels | 569.0 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P672295?

Alternative CEC solar modules from competing brands near Sunrise Solartech SR-P672295 (295.0 W), including Chinaland Solar Energy HSE295-72P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Chinaland Solar Energy HSE295-72P**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72p/) Chinaland Solar Energy | 295.0 W | Tie (0 W) | 43.3 V | 15.28% | 88.5% |
| [**Chinaland Solar Energy HSE295-72M**](https://epri-peac.com/solar-equipment/modules/chinaland-solar-energy/chinaland-solar-energy-hse295-72m/) Chinaland Solar Energy | 295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| [**BYD Company Limited BYD295P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd295p6k-36/) BYD Company Limited | 295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| [**Centrosolar America TP7 295xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-295xx/) Centrosolar America | 295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P672295?

Evaluate Sunrise Solartech SR-P672295 (295.0 W STC, 43.77 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P672295 reaches 50.84 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P672295 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Sunrise Solartech SR-P672295 8 kW Residential Fit

Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE295-72P.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunrise Solartech SR-P672295 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Sunrise Solartech SR-P672295?

Multiplying Sunrise Solartech SR-P672295's 8.95 A short-circuit current by 1.56 equals 13.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Sunrise Solartech SR-P672295 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.27 V cold Voc at 14 F and handles 8.95 A Isc; string inverters cap Sunrise Solartech SR-P672295 at 12 panels on 600 V.

### Is Sunrise Solartech SR-P672295 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunrise Solartech SR-P672295 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

## Related Pages

Compare Sunrise Solartech equipment, Chinaland Solar Energy HSE295-72P specs, utility payback rates, and NEC string calculators alongside Sunrise Solartech SR-P672295.

[All Sunrise Solartech Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunrise-solartech/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sunrise Solartech

- [All Sunrise Solartech Specs](https://epri-peac.com/solar-equipment/brands/sunrise-solartech/)
- [Sunrise Solartech SR-M672310](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-m672310/)
- [Sunrise Solartech SR-M672305](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-m672305/)
- [Sunrise Solartech SR-P672290](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672290/)
- [Sunrise Solartech SR-P672285](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672285/)
- [Sunrise Solartech SR-P672280](https://epri-peac.com/solar-equipment/modules/sunrise-solartech/sunrise-solartech-sr-p672280/)