SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M is a 555.0 W STC (515.4 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.38% efficiency, 50.5 V Voc at 25 C, and 55.52 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 555.0 W

- **PTC Wattage** : 515.4 W

- **Voc @ 25C** : 50.5 V

- **Efficiency** : 22.38%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (Mono-c-Si) residential solar systems.

Homeowners evaluating SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M need 11 panels for 6 kW or 15 panels (400 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.284%/C) pushes open-circuit voltage to 55.52 V at 14 F and 56.95 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Fall Across Listed CEC Models?

Comparison of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (555.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Relative ranking of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Summary of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,550 / 21,677

### Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,267

### 22.38% Aperture Efficiency

Power density 223.8 W/m2 (2.47 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.52 V at -10 C (555.2 V string) and 56.95 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,325 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,731 W PTC; NEC 690.8 OCPD floor is 21.67 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.5 * (1 + (-0.284/100) * (-10 - 25)) = 55.52 V | OCPD = 1.56 * 13.89 = 21.67 A

Inputs from CEC Modules.csv for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M: Voc=50.5 V, beta_Voc=-0.284%/C, Isc=13.89 A, STC=555.0 W, Area=2.48 m2.

**Result:** 10 panels max on 600 V (555.2 V); 15 panels for 8 kW (400 sq ft).

## What Are the Published CEC Specifications for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Complete CEC test sheet for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M including Isc (13.89 A), Voc (50.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 515.4 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.4 V / 13.08 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.284 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.38% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.11 kW | 294 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 15 | 8.32 kW | 400 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 19 | 10.54 kW | 507 sq ft | $2,638 | $4,461 |

## Which Sibling Wattage & Trim Variants Belong to This SUNPLUS OPTIMUM LIMITED Series?

Related SUNPLUS OPTIMUM LIMITED power steps and black/silver trims consolidated into this SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M series guide.

Sibling CEC listings grouped into the SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-550M** | 550.0 W | 510.6 W | 50.3 V | 42.3 V | 22.18% |
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M** | 555.0 W | 515.4 W | 50.5 V | 42.4 V | 22.38% |
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-560M** | 560.0 W | 520.2 W | 50.7 V | 42.6 V | 22.58% |

## How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (50.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.5V and beta_Voc=-0.284%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.95 V | 10 panels | 569.5 V | 17 panels |
| **-10 C (14 F)** | 55.52 V | 10 panels | 555.2 V | 18 panels |
| **0 C (32 F)** | 54.09 V | 11 panels | 595.0 V | 18 panels |
| **25 C (77 F STC)** | 50.5 V | 11 panels | 555.5 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Four comparable CEC modules such as Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555 (555.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-dg-f-bh-555/) Chint New Energy Technology Co Ltd | 555.0 W | Tie (0 W) | 50.5 V | 22.38% | 92.9% |
| [**ASTORIOS Holding Inc ASTR144BDG-555W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr144bdg-555w-us/) ASTORIOS Holding Inc | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.7% |
| [**AXITEC AC-555MBT/144US**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144us/) AXITEC | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |
| [**Energy America LLC EA-ZLK7-SHDB144-555/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-555-m/) Energy America LLC | 555.0 W | Tie (0 W) | 50.4 V | 21.51% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

Evaluate SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M (555.0 W STC, 50.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 400 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M 8 kW Residential Fit

Needs 15 modules (400 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 515.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M by SUNPLUS OPTIMUM LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M PTC wattage (515.4 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 515.4 W PTC (92.9% retention) across SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M's 2.48 m2 aperture.

### Who should skip SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M panels (400 sq ft) leave unusable roof gaps vs. Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555.

### What is the 1,000 V commercial string limit for SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M?

On 1,000 V commercial inverters at -10 C (55.52 V cold Voc), SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

## Related Pages

Compare SUNPLUS OPTIMUM LIMITED equipment, Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555 specs, utility payback rates, and NEC string calculators alongside SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M.

[All SUNPLUS OPTIMUM LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SUNPLUS OPTIMUM LIMITED

- [All SUNPLUS OPTIMUM LIMITED Specs](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-limited/)
- [SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66nhbd-685m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-675m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-665M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-665m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66NHBD-665M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66nhbd-665m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-640M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-640m/)