title: "SUNPLUS OPTIMUM LIMITED Specs (540.0W, 49.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr4-72hbd-540m/
description: "CEC datasheet for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M: 540.0W STC, 49.9V Voc, 15-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M — CEC Solar Module Specifications

Manufacturer: [**SUNPLUS OPTIMUM LIMITED**](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-limited/) Registry: **CEC Verified Engineering Specification**

SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M is a 540.0 W STC (501.0 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.77% efficiency, 49.9 V Voc at 25 C, and 54.86 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 540.0 W

- **PTC Wattage** : 501.0 W

- **Voc @ 25C** : 49.9 V

- **Efficiency** : 21.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M Compare Against Peer CEC Listings?

Engineering position of SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M (540.0 W STC) vs. Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M pairs strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677) with 49.9 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,515 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF offers a 540.0 W alternative.

## Where Does SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M Fall Across Listed CEC Models?

Plots SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Benchmarks SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M on STC wattage, thermal PTC/STC retention, and 21.77 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M by SUNPLUS OPTIMUM LIMITED.

Rank #3,265 / 21,677

### Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,681

### 21.77% Aperture Efficiency

Power density 217.7 W/m2 (1.86 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.86 V at -10 C (548.6 V string) and 56.28 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,100 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,515 W PTC; NEC 690.8 OCPD floor is 21.31 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.9 * (1 + (-0.284/100) * (-10 - 25)) = 54.86 V | OCPD = 1.56 * 13.66 = 21.31 A

Inputs from CEC Modules.csv for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M: Voc=49.9 V, beta_Voc=-0.284%/C, Isc=13.66 A, STC=540.0 W, Area=2.48 m2.

**Result:** 10 panels max on 600 V (548.6 V); 15 panels for 8 kW (400 sq ft).

## What Are the Published CEC Specifications for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Laboratory test ratings recorded for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 501.0 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.9 V / 12.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.284 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.77% (2.48 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (400 sq ft at 8 kW), and estimated Year-1 electric bill offset for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.48 kW | 320 sq ft | $1,622 | $2,742 |
| **8 kW Class** | 15 | 8.1 kW | 400 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 19 | 10.26 kW | 507 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This SUNPLUS OPTIMUM LIMITED Series?

Sibling wattage bins and frame colors grouped with SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M under SUNPLUS OPTIMUM LIMITED to prevent duplicate spec pages.

Sibling CEC listings grouped into the SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-535M** | 535.0 W | 496.2 W | 49.7 V | 41.8 V | 21.57% |
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M** | 540.0 W | 501.0 W | 49.9 V | 41.9 V | 21.77% |
| **SUNPLUS OPTIMUM LIMITED SR4-72HBD-545M** | 545.0 W | 505.8 W | 50.1 V | 42.1 V | 21.98% |

## How Many SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M (beta_Voc -0.284%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.9V and beta_Voc=-0.284%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.28 V | 10 panels | 562.8 V | 17 panels |
| **-10 C (14 F)** | 54.86 V | 10 panels | 548.6 V | 18 panels |
| **0 C (32 F)** | 53.44 V | 11 panels | 587.8 V | 18 panels |
| **25 C (77 F STC)** | 49.9 V | 12 panels | 598.8 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Closest cross-brand CEC competitors to SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M matched near 540.0 W STC and 49.9 V Voc, led by Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-540-h-hc-bf/) Boviet Solar Technology Co Ltd | 540.0 W | Tie (0 W) | 49.89 V | 20.77% | 94.1% |
| [**ASTORIOS Holding Inc ASTR144BDG-540W-US**](https://epri-peac.com/solar-equipment/modules/astorios-holding-inc/astorios-holding-inc-astr144bdg-540w-us/) ASTORIOS Holding Inc | 540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| [**Energy America LLC EA-ZLK7-SHDB144-540/M**](https://epri-peac.com/solar-equipment/modules/energy-america-llc/energy-america-llc-ea-zlk7-shdb144-540-m/) Energy America LLC | 540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| [**Hansol Technics Co Ltd HA540XD-GNEA0**](https://epri-peac.com/solar-equipment/modules/hansol-technics-co-ltd/hansol-technics-co-ltd-ha540xd-gnea0/) Hansol Technics Co Ltd | 540.0 W | Tie (0 W) | 49.8 V | 21.09% | 94.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Evaluate SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M (540.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M reaches 56.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 400 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M 8 kW Residential Fit

Needs 15 modules (400 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 501.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M by SUNPLUS OPTIMUM LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M?

Multiplying SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M's 13.66 A short-circuit current by 1.56 equals 21.31 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.86 V cold Voc at 14 F and handles 13.66 A Isc; string inverters cap SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M at 10 panels on 600 V.

### Is SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare SUNPLUS OPTIMUM LIMITED equipment, Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF specs, utility payback rates, and NEC string calculators alongside SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M.

[All SUNPLUS OPTIMUM LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SUNPLUS OPTIMUM LIMITED

- [All SUNPLUS OPTIMUM LIMITED Specs](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-limited/)
- [SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66nhbd-685m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-675m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-665M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-665m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66NHBD-665M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66nhbd-665m/)
- [SUNPLUS OPTIMUM LIMITED SR5-66HBD-640M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-limited/sunplus-optimum-limited-sr5-66hbd-640m/)