title: "SUNPLUS OPTIMUM INC SR4-54HTB-435M Specs (435.0W, 39.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunplus-optimum-inc/sunplus-optimum-inc-sr4-54htb-435m/
description: "CEC datasheet for SUNPLUS OPTIMUM INC SR4-54HTB-435M: 435.0W STC, 39.2V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# SUNPLUS OPTIMUM INC SR4-54HTB-435M — CEC Solar Module Specifications

Manufacturer: [**SUNPLUS OPTIMUM INC**](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-inc/) Registry: **CEC Verified Engineering Specification**

SUNPLUS OPTIMUM INC SR4-54HTB-435M is a 435.0 W STC (405.6 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 23.02% efficiency, 39.2 V Voc at 25 C, and 42.9 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 405.6 W

- **Voc @ 25C** : 39.2 V

- **Efficiency** : 23.02%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SUNPLUS OPTIMUM INC SR4-54HTB-435M Compare Against Peer CEC Listings?

How SUNPLUS OPTIMUM INC SUNPLUS OPTIMUM INC SR4-54HTB-435M handles rooftop heat (405.6 W PTC), 8 kW sizing, and cold winter string voltage.

SUNPLUS OPTIMUM INC builds the SUNPLUS OPTIMUM INC SR4-54HTB-435M (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 230.2 W/m2 (3.11 percentage points above 19.91% CEC median). Compared against Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 (435.0 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Lower 39.2 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.75 A overcurrent floor served by a 25 A breaker.

## Where Does SUNPLUS OPTIMUM INC SR4-54HTB-435M Fall Across Listed CEC Models?

Where SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Percentile placement of SUNPLUS OPTIMUM INC SR4-54HTB-435M across power density (230.2 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Four critical engineering numbers homeowners and solar installers check first when reviewing SUNPLUS OPTIMUM INC SR4-54HTB-435M specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,124

### 23.02% Aperture Efficiency

Power density 230.2 W/m2 (3.11 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.9 V at -10 C (557.7 V string) and 43.96 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 35.9 m2 (387 sq ft) producing 7,706 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.2 * (1 + (-0.27/100) * (-10 - 25)) = 42.9 V | OCPD = 1.56 * 13.94 = 21.75 A

Inputs from CEC Modules.csv for SUNPLUS OPTIMUM INC SR4-54HTB-435M: Voc=39.2 V, beta_Voc=-0.27%/C, Isc=13.94 A, STC=435.0 W, Area=1.89 m2.

**Result:** 13 panels max on 600 V (557.7 V); 19 panels for 8 kW (387 sq ft).

## What Are the Published CEC Specifications for SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SUNPLUS OPTIMUM INC SR4-54HTB-435M.

Official California Energy Commission (NREL SAM) test parameters for SUNPLUS OPTIMUM INC SR4-54HTB-435M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 405.6 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.2 V / 13.51 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.27 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 23.02% (1.89 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SUNPLUS OPTIMUM INC SR4-54HTB-435M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 285 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 387 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 468 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This SUNPLUS OPTIMUM INC Series?

All closely matched SUNPLUS OPTIMUM INC wattages and cosmetic trims sharing the SUNPLUS OPTIMUM INC SR4-54HTB-435M architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the SUNPLUS OPTIMUM INC SR4-54HTB-435M wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SUNPLUS OPTIMUM INC SR4-54HTB-425M** | 425.0 W | 396.0 W | 38.8 V | 31.8 V | 22.49% |
| **SUNPLUS OPTIMUM INC SR4-54HTB-430M** | 430.0 W | 400.8 W | 39.0 V | 32.0 V | 22.75% |
| **SUNPLUS OPTIMUM INC SR4-54HTB-435M** | 435.0 W | 405.6 W | 39.2 V | 32.2 V | 23.02% |
| **SUNPLUS OPTIMUM INC SR4-54HTB-440M** | 440.0 W | 410.4 W | 39.4 V | 32.4 V | 23.28% |
| **SUNPLUS OPTIMUM INC SR4-54HTB-445M** | 445.0 W | 415.2 W | 39.6 V | 32.6 V | 23.54% |

## How Many SUNPLUS OPTIMUM INC SR4-54HTB-435M Modules Fit in a Cold-Weather String?

Maximum series module counts for SUNPLUS OPTIMUM INC SR4-54HTB-435M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.2V and beta_Voc=-0.27%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.96 V | 13 panels | 571.5 V | 22 panels |
| **-10 C (14 F)** | 42.9 V | 13 panels | 557.7 V | 23 panels |
| **0 C (32 F)** | 41.85 V | 14 panels | 585.9 V | 23 panels |
| **25 C (77 F STC)** | 39.2 V | 15 panels | 588.0 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Alternative CEC solar modules from competing brands near SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W), including Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-lv-n-435/) Elin Energy (Sirius PV) | 435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
| [**Elin Energy (Sirius PV) ELNSM54M-HC-N-435**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm54m-hc-n-435/) Elin Energy (Sirius PV) | 435.0 W | Tie (0 W) | 39.1 V | 22.42% | 95.0% |
| [**Auxin Solar AXN10M435B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m435b/) Auxin Solar | 435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.2% |
| [**Auxin Solar AXN10M435W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m435w/) Auxin Solar | 435.0 W | Tie (0 W) | 38.66 V | 22.42% | 93.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Evaluate SUNPLUS OPTIMUM INC SR4-54HTB-435M (435.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SUNPLUS OPTIMUM INC SR4-54HTB-435M reaches 43.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 387 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (387 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SUNPLUS OPTIMUM INC SR4-54HTB-435M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SUNPLUS OPTIMUM INC SR4-54HTB-435M 8 kW Residential Fit

Needs 19 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 405.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SUNPLUS OPTIMUM INC SR4-54HTB-435M by SUNPLUS OPTIMUM INC grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SUNPLUS OPTIMUM INC SR4-54HTB-435M?

Multiplying SUNPLUS OPTIMUM INC SR4-54HTB-435M's 13.94 A short-circuit current by 1.56 equals 21.75 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can SUNPLUS OPTIMUM INC SR4-54HTB-435M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.9 V cold Voc at 14 F and handles 13.94 A Isc; string inverters cap SUNPLUS OPTIMUM INC SR4-54HTB-435M at 13 panels on 600 V.

### Is SUNPLUS OPTIMUM INC SR4-54HTB-435M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SUNPLUS OPTIMUM INC SR4-54HTB-435M rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

## Related Pages

Compare SUNPLUS OPTIMUM INC equipment, Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435 specs, utility payback rates, and NEC string calculators alongside SUNPLUS OPTIMUM INC SR4-54HTB-435M.

[All SUNPLUS OPTIMUM INC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-inc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SUNPLUS OPTIMUM INC

- [All SUNPLUS OPTIMUM INC Specs](https://epri-peac.com/solar-equipment/brands/sunplus-optimum-inc/)
- [SUNPLUS OPTIMUM INC SR4-54HTB-410M](https://epri-peac.com/solar-equipment/modules/sunplus-optimum-inc/sunplus-optimum-inc-sr4-54htb-410m/)