title: "Sunpal Power Co Ltd SP520M-72HB Specs (520.0W, 49.18V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunpal-power-co-ltd/sunpal-power-co-ltd-sp520m-72hb/
description: "CEC datasheet for Sunpal Power Co Ltd SP520M-72HB: 520.0W STC, 49.18V Voc, 16-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Sunpal Power Co Ltd SP520M-72HB — CEC Solar Module Specifications

Manufacturer: [**Sunpal Power Co Ltd**](https://epri-peac.com/solar-equipment/brands/sunpal-power-co-ltd/) Registry: **CEC Verified Engineering Specification**

Sunpal Power Co Ltd SP520M-72HB is a 520.0 W STC (488.3 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.16% efficiency, 49.18 V Voc at 25 C, and 53.64 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 520.0 W

- **PTC Wattage** : 488.3 W

- **Voc @ 25C** : 49.18 V

- **Efficiency** : 20.16%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sunpal Power Co Ltd SP520M-72HB Compare Against Peer CEC Listings?

How Sunpal Power Co Ltd Sunpal Power Co Ltd SP520M-72HB handles rooftop heat (488.3 W PTC), 8 kW sizing, and cold winter string voltage.

Sunpal Power Co Ltd builds the Sunpal Power Co Ltd SP520M-72HB (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). Compared against AXITEC AC-520MH/144VB (520.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 49.18 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 21.12 A overcurrent floor served by a 25 A breaker.

## Where Does Sunpal Power Co Ltd SP520M-72HB Fall Across Listed CEC Models?

Where Sunpal Power Co Ltd SP520M-72HB (520.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Sunpal Power Co Ltd SP520M-72HB?

Percentile placement of Sunpal Power Co Ltd SP520M-72HB across power density (201.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Sunpal Power Co Ltd SP520M-72HB?

Four critical engineering numbers homeowners and solar installers check first when reviewing Sunpal Power Co Ltd SP520M-72HB specifications.

Rank #4,199 / 21,677

### Top 19.9% STC Output

520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,907

### 20.16% Aperture Efficiency

Power density 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.64 V at -10 C (590.0 V string) and 54.91 V at -20 C (10 max).

 8 kW Reference Array

### 16 Panels = 8,320 W STC

Occupies 41.3 m2 (444 sq ft) producing 7,813 W PTC; NEC 690.8 OCPD floor is 21.12 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.18 * (1 + (-0.259/100) * (-10 - 25)) = 53.64 V | OCPD = 1.56 * 13.54 = 21.12 A

Inputs from CEC Modules.csv for Sunpal Power Co Ltd SP520M-72HB: Voc=49.18 V, beta_Voc=-0.259%/C, Isc=13.54 A, STC=520.0 W, Area=2.58 m2.

**Result:** 11 panels max on 600 V (590.0 V); 16 panels for 8 kW (444 sq ft).

## What Are the Published CEC Specifications for Sunpal Power Co Ltd SP520M-72HB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sunpal Power Co Ltd SP520M-72HB.

Official California Energy Commission (NREL SAM) test parameters for Sunpal Power Co Ltd SP520M-72HB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 488.3 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.5 V / 12.84 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.259 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.16% (2.58 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Sunpal Power Co Ltd SP520M-72HB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sunpal Power Co Ltd SP520M-72HB (520.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.24 kW | 333 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 16 | 8.32 kW | 444 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 20 | 10.4 kW | 555 sq ft | $2,603 | $4,402 |

## How Many Sunpal Power Co Ltd SP520M-72HB Modules Fit in a Cold-Weather String?

Maximum series module counts for Sunpal Power Co Ltd SP520M-72HB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.18V and beta_Voc=-0.259%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.91 V | 10 panels | 549.1 V | 18 panels |
| **-10 C (14 F)** | 53.64 V | 11 panels | 590.0 V | 18 panels |
| **0 C (32 F)** | 52.36 V | 11 panels | 576.0 V | 19 panels |
| **25 C (77 F STC)** | 49.18 V | 12 panels | 590.2 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Sunpal Power Co Ltd SP520M-72HB?

Alternative CEC solar modules from competing brands near Sunpal Power Co Ltd SP520M-72HB (520.0 W), including AXITEC AC-520MH/144VB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-520MH/144VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-520mh-144vb/) AXITEC | 520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| [**ELITE Solar ET-M772BH520BB**](https://epri-peac.com/solar-equipment/modules/elite-solar/elite-solar-et-m772bh520bb/) ELITE Solar | 520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| [**Boviet Solar Technology Co Ltd BVM7612M-520-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7612m-520-h-hc/) Boviet Solar Technology Co Ltd | 520.0 W | Tie (0 W) | 49.39 V | 20.04% | 93.8% |
| [**Chint New Energy Technology Co Ltd CHSM72M-HC-520**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm72m-hc-520/) Chint New Energy Technology Co Ltd | 520.0 W | Tie (0 W) | 48.9 V | 20.97% | 92.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sunpal Power Co Ltd SP520M-72HB?

Evaluate Sunpal Power Co Ltd SP520M-72HB (520.0 W STC, 49.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Sunpal Power Co Ltd SP520M-72HB reaches 54.91 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (444 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sunpal Power Co Ltd SP520M-72HB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Sunpal Power Co Ltd SP520M-72HB 8 kW Residential Fit

Needs 16 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-520MH/144VB.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 488.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunpal Power Co Ltd SP520M-72HB by Sunpal Power Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Sunpal Power Co Ltd SP520M-72HB?

Multiplying Sunpal Power Co Ltd SP520M-72HB's 13.54 A short-circuit current by 1.56 equals 21.12 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Sunpal Power Co Ltd SP520M-72HB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.64 V cold Voc at 14 F and handles 13.54 A Isc; string inverters cap Sunpal Power Co Ltd SP520M-72HB at 11 panels on 600 V.

### Is Sunpal Power Co Ltd SP520M-72HB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunpal Power Co Ltd SP520M-72HB rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.

## Related Pages

Compare Sunpal Power Co Ltd equipment, AXITEC AC-520MH/144VB specs, utility payback rates, and NEC string calculators alongside Sunpal Power Co Ltd SP520M-72HB.

[All Sunpal Power Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunpal-power-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sunpal Power Co Ltd

- [All Sunpal Power Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/sunpal-power-co-ltd/)
- [Sunpal Power Co Ltd SP685M-66H](https://epri-peac.com/solar-equipment/modules/sunpal-power-co-ltd/sunpal-power-co-ltd-sp685m-66h/)
- [Sunpal Power Co Ltd SP660M-66H](https://epri-peac.com/solar-equipment/modules/sunpal-power-co-ltd/sunpal-power-co-ltd-sp660m-66h/)
- [Sunpal Power Co Ltd SP640M-66H](https://epri-peac.com/solar-equipment/modules/sunpal-power-co-ltd/sunpal-power-co-ltd-sp640m-66h/)
- [Sunpal Power Co Ltd SP560M-72HB](https://epri-peac.com/solar-equipment/modules/sunpal-power-co-ltd/sunpal-power-co-ltd-sp560m-72hb/)