---
title: "Sunflare Co FLEX60-185W Specs (185.0W, 36.63V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex60-185w/
description: "CEC datasheet for Sunflare Co FLEX60-185W: 185.0W STC, 36.63V Voc, 44-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Sunflare Co FLEX60-185W — CEC Solar Module Specifications

Manufacturer: [**Sunflare Co**](https://epri-peac.com/solar-equipment/brands/sunflare-co/) Registry: **CEC Verified Engineering Specification**

Sunflare Co FLEX60-185W is a 185.0 W STC (183.8 W PTC) Thin Film solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 11.28% efficiency, 36.63 V Voc at 25 C, and 40.46 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 185.0 W

- **PTC Wattage** : 183.8 W

- **Voc @ 25C** : 36.63 V

- **Efficiency** : 11.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sunflare Co FLEX60-185W Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunflare Co FLEX60-185W: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Measured at 185.0 W STC and 183.8 W PTC, Sunflare Co FLEX60-185W sits -200.0 W vs all-CEC median (below all-CEC median; higher than 2.1% of peers) among 21,677 listed modules. Power density reaches 112.8 W/m2 (8.63 percentage points below 19.91% CEC median). Lower 36.63 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Solartech Power SPM195P rates 195.0 W.

## Where Does Sunflare Co FLEX60-185W Fall Across Listed CEC Models?

Distribution marker showing Sunflare Co FLEX60-185W (185.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Sunflare Co FLEX60-185W?

Dataset percentiles tracking Sunflare Co FLEX60-185W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## What Do the Dataset Ranks Show for Sunflare Co FLEX60-185W?

Benchmark highlights for Sunflare Co FLEX60-185W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #21,185 / 21,677

### 185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,592

### 11.28% Aperture Efficiency

Power density 112.8 W/m2 (8.63 percentage points below 19.91% CEC median). PTC/STC ratio: 99.4% (rank #1).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.46 V at -10 C (566.4 V string) and 41.56 V at -20 C (14 max).

 8 kW Reference Array

### 44 Panels = 8,140 W STC

Occupies 72.2 m2 (777 sq ft) producing 8,087 W PTC; NEC 690.8 OCPD floor is 11.75 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.63 * (1 + (-0.299/100) * (-10 - 25)) = 40.46 V | OCPD = 1.56 * 7.53 = 11.75 A

Inputs from CEC Modules.csv for Sunflare Co FLEX60-185W: Voc=36.63 V, beta_Voc=-0.299%/C, Isc=7.53 A, STC=185.0 W, Area=1.64 m2.

**Result:** 14 panels max on 600 V (566.4 V); 44 panels for 8 kW (777 sq ft).

## What Are the Published CEC Specifications for Sunflare Co FLEX60-185W?

Official CEC datasheet figures for Sunflare Co FLEX60-185W (Thin Film) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Sunflare Co FLEX60-185W.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 183.8 W (99.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.63 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 28.33 V / 6.53 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.299 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 11.28% (1.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Thin Film) | Monofacial backsheet |

## How Many Sunflare Co FLEX60-185W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunflare Co FLEX60-185W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 33 | 6.11 kW | 583 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 44 | 8.14 kW | 777 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 55 | 10.18 kW | 971 sq ft | $2,548 | $4,308 |

## Which Sibling Wattage & Trim Variants Belong to This Sunflare Co Series?

Consolidated Sunflare Co wattage variants sharing the Sunflare Co FLEX60-185W mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Sunflare Co FLEX60-185W wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Sunflare Co FLEX60-175W** | 175.0 W | 173.8 W | 35.95 V | 28.18 V | 10.67% |
| **Sunflare Co FLEX60-177W** | 177.0 W | 153.5 W | 36.14 V | 27.27 V | 10.79% |
| **Sunflare Co FLEX60-180W** | 180.0 W | 178.8 W | 36.4 V | 28.68 V | 10.98% |
| **Sunflare Co FLEX60-185W** | 185.0 W | 183.8 W | 36.63 V | 28.33 V | 11.28% |
| **Sunflare Co FLEX60-190W** | 190.0 W | 188.8 W | 36.93 V | 29.26 V | 11.59% |
| **Sunflare Co FLEX60-195W** | 195.0 W | 193.7 W | 37.6 V | 29.86 V | 11.89% |

## How Many Sunflare Co FLEX60-185W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunflare Co FLEX60-185W (40.46 V at 14 F).

Computed from Voc=36.63V and beta_Voc=-0.299%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.56 V | 14 panels | 581.8 V | 24 panels |
| **-10 C (14 F)** | 40.46 V | 14 panels | 566.4 V | 24 panels |
| **0 C (32 F)** | 39.37 V | 15 panels | 590.5 V | 25 panels |
| **25 C (77 F STC)** | 36.63 V | 16 panels | 586.1 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Sunflare Co FLEX60-185W?

Competing CEC solar panels closest to Sunflare Co FLEX60-185W in nameplate wattage and Voc, starting with Solartech Power SPM195P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Solartech Power SPM195P**](https://epri-peac.com/solar-equipment/modules/solartech-power/solartech-power-spm195p/) Solartech Power | 195.0 W | +10.0 W | 35.6 V | 11.96% | 83.8% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-P185**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-p185/) Hanwha Qcells (Qidong) Co Ltd | 185.0 W | Tie (0 W) | 32.5 V | 12.38% | 88.6% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-M190**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-m190/) Hanwha Qcells (Qidong) Co Ltd | 190.0 W | +5.0 W | 32.8 V | 12.72% | 88.7% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-M190B**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-m190b/) Hanwha Qcells (Qidong) Co Ltd | 190.0 W | +5.0 W | 32.8 V | 12.72% | 88.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sunflare Co FLEX60-185W?

Evaluate Sunflare Co FLEX60-185W (185.0 W STC, 36.63 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Sunflare Co FLEX60-185W reaches 41.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 777 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (777 sq ft).
- 2026 tax credit baseline: cash residential installs of Sunflare Co FLEX60-185W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Sunflare Co FLEX60-185W 8 kW Residential Fit

Needs 44 modules (777 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Solartech Power SPM195P.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 183.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunflare Co FLEX60-185W by Sunflare Co grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Sunflare Co FLEX60-185W panels fit on a 600 V winter solar string?

At -10 C (14 F), Sunflare Co FLEX60-185W cold Voc rises from 36.63 V to 40.46 V (beta_Voc -0.299%/C), capping a 600 V string at 14 panels (566.4 V).

### How much roof area does an 8 kW array of Sunflare Co FLEX60-185W need?

An 8 kW DC system uses 44 Sunflare Co FLEX60-185W modules (8,140 W STC / 8,087 W PTC), covering roughly 777 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

### How does Sunflare Co FLEX60-185W compare against Solartech Power SPM195P?

Sunflare Co FLEX60-185W outputs 185.0 W STC (36.63 V Voc, rank #21,185 of 21,677), while Solartech Power SPM195P delivers 195.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Sunflare Co equipment, Solartech Power SPM195P specs, utility payback rates, and NEC string calculators alongside Sunflare Co FLEX60-185W.

[All Sunflare Co Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sunflare-co/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sunflare Co

- [All Sunflare Co Specs](https://epri-peac.com/solar-equipment/brands/sunflare-co/)
- [Sunflare Co FLEX60-185W-M20](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex60-185w-m20/)
- [Sunflare Co FLEX60-180W-M20-A](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex60-180w-m20-a/)
- [Sunflare Co FLEX60-165W](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex60-165w/)
- [Sunflare Co FLEX60-165W-M20-A](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex60-165w-m20-a/)
- [Sunflare Co FLEX20-60W](https://epri-peac.com/solar-equipment/modules/sunflare-co/sunflare-co-flex20-60w/)
