title: "Sonali Energees SS 270 Specs (270.0W, 43.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sonali-energees/sonali-energees-ss-270/
description: "CEC datasheet for Sonali Energees SS 270: 270.0W STC, 43.2V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Sonali Energees SS 270 — CEC Solar Module Specifications

Manufacturer: [**Sonali Energees**](https://epri-peac.com/solar-equipment/brands/sonali-energees/) Registry: **CEC Verified Engineering Specification**

Sonali Energees SS 270 is a 270.0 W STC (233.2 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 14.16% efficiency, 43.2 V Voc at 25 C, and 49.01 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 270.0 W

- **PTC Wattage** : 233.2 W

- **Voc @ 25C** : 43.2 V

- **Efficiency** : 14.16%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sonali Energees SS 270 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Sonali Energees SS 270 (Multi-c-Si) residential solar systems.

Homeowners evaluating Sonali Energees SS 270 need 23 panels for 6 kW or 30 panels (616 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (616 sq ft). Under NEC 690.7(A), beta_Voc (-0.384%/C) pushes open-circuit voltage to 49.01 V at 14 F and 50.66 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Sonali Energees SS 270 Fall Across Listed CEC Models?

Comparison of Sonali Energees SS 270 (270.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Sonali Energees SS 270?

Relative ranking of Sonali Energees SS 270 across nameplate watts, 86.4% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Sonali Energees SS 270?

Summary of Sonali Energees SS 270 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.

Rank #18,572 / 21,677

### 270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,764

### 14.16% Aperture Efficiency

Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 86.4% (rank #21,632).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.01 V at -10 C (588.1 V string) and 50.66 V at -20 C (11 max).

 8 kW Reference Array

### 30 Panels = 8,100 W STC

Occupies 57.2 m2 (616 sq ft) producing 6,996 W PTC; NEC 690.8 OCPD floor is 12.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.2 * (1 + (-0.384/100) * (-10 - 25)) = 49.01 V | OCPD = 1.56 * 8.05 = 12.56 A

Inputs from CEC Modules.csv for Sonali Energees SS 270: Voc=43.2 V, beta_Voc=-0.384%/C, Isc=8.05 A, STC=270.0 W, Area=1.907 m2.

**Result:** 12 panels max on 600 V (588.1 V); 30 panels for 8 kW (616 sq ft).

## What Are the Published CEC Specifications for Sonali Energees SS 270?

Complete CEC test sheet for Sonali Energees SS 270 including Isc (8.05 A), Voc (43.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Sonali Energees SS 270.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 233.2 W (86.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.0 V / 7.5 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.384 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.16% (1.907 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Sonali Energees SS 270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Sonali Energees SS 270.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.21 kW | 472 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 30 | 8.1 kW | 616 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 38 | 10.26 kW | 780 sq ft | $2,568 | $4,342 |

## How Many Sonali Energees SS 270 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Sonali Energees SS 270 (43.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=43.2V and beta_Voc=-0.384%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.66 V | 11 panels | 557.3 V | 19 panels |
| **-10 C (14 F)** | 49.01 V | 12 panels | 588.1 V | 20 panels |
| **0 C (32 F)** | 47.35 V | 12 panels | 568.2 V | 21 panels |
| **25 C (77 F STC)** | 43.2 V | 13 panels | 561.6 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Sonali Energees SS 270?

Four comparable CEC modules such as Anhui Rinengzhongtian Semiconductor Development QJM270-72 (270.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Anhui Rinengzhongtian Semiconductor Development QJM270-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm270-72/) Anhui Rinengzhongtian Semiconductor Development | 270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| [**Centrosolar America DP72 270**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-270/) Centrosolar America | 270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| [**AXITEC AC-270P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-156-72s/) AXITEC | 270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| [**Advance Power API-P265**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p265/) Advance Power | 265.0 W | -5.0 W | 43.27 V | 13.58% | 89.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sonali Energees SS 270?

Evaluate Sonali Energees SS 270 (270.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Sonali Energees SS 270 reaches 50.66 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 616 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (616 sq ft).
- 2026 tax credit baseline: cash residential installs of Sonali Energees SS 270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Sonali Energees SS 270 8 kW Residential Fit

Needs 30 modules (616 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM270-72.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sonali Energees SS 270 by Sonali Energees grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Sonali Energees SS 270 PTC wattage (233.2 W) lower than STC (270.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 233.2 W PTC (86.4% retention) across Sonali Energees SS 270's 1.907 m2 aperture.

### Who should skip Sonali Energees SS 270 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Sonali Energees SS 270 panels (616 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJM270-72.

### What is the 1,000 V commercial string limit for Sonali Energees SS 270?

On 1,000 V commercial inverters at -10 C (49.01 V cold Voc), Sonali Energees SS 270 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Sonali Energees SS 270.

## Related Pages

Compare Sonali Energees equipment, Anhui Rinengzhongtian Semiconductor Development QJM270-72 specs, utility payback rates, and NEC string calculators alongside Sonali Energees SS 270.

[All Sonali Energees Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sonali-energees/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sonali Energees

- [All Sonali Energees Specs](https://epri-peac.com/solar-equipment/brands/sonali-energees/)
- [Sonali Energees SS 315](https://epri-peac.com/solar-equipment/modules/sonali-energees/sonali-energees-ss-315/)
- [Sonali Energees SS 290](https://epri-peac.com/solar-equipment/modules/sonali-energees/sonali-energees-ss-290/)