title: "Sonali Energees USA LLC Specs (455.0W, 50.4V Voc)"
url: https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss144h-455mb/
description: "CEC datasheet for Sonali Energees USA LLC SS144H-455MB: 455.0W STC, 50.4V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Sonali Energees USA LLC SS144H-455MB — CEC Solar Module Specifications

Manufacturer: [**Sonali Energees USA LLC**](https://epri-peac.com/solar-equipment/brands/sonali-energees-usa-llc/) Registry: **CEC Verified Engineering Specification**

Sonali Energees USA LLC SS144H-455MB is a 455.0 W STC (425.5 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 20.87% efficiency, 50.4 V Voc at 25 C, and 55.37 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 455.0 W

- **PTC Wattage** : 425.5 W

- **Voc @ 25C** : 50.4 V

- **Efficiency** : 20.87%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Sonali Energees USA LLC SS144H-455MB Compare Against Peer CEC Listings?

How Sonali Energees USA LLC Sonali Energees USA LLC SS144H-455MB handles rooftop heat (425.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Sonali Energees USA LLC SS144H-455MB exhibits 11.41 A short-circuit current, requiring a 17.8 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #5,417 of 21,677 (45.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.2 m2 for an 8 kW system (22 panels for 10 kW). Higher 50.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Sonali Energees USA LLC SS144H-455MB Fall Across Listed CEC Models?

Where Sonali Energees USA LLC SS144H-455MB (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Sonali Energees USA LLC SS144H-455MB?

Percentile placement of Sonali Energees USA LLC SS144H-455MB across power density (208.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Sonali Energees USA LLC SS144H-455MB?

Four critical engineering numbers homeowners and solar installers check first when reviewing Sonali Energees USA LLC SS144H-455MB specifications.

Rank #5,417 / 21,677

### Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,998

### 20.87% Aperture Efficiency

Power density 208.7 W/m2 (0.96 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.37 V at -10 C (553.7 V string) and 56.8 V at -20 C (10 max).

 8 kW Reference Array

### 18 Panels = 8,190 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,659 W PTC; NEC 690.8 OCPD floor is 17.8 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.4 * (1 + (-0.282/100) * (-10 - 25)) = 55.37 V | OCPD = 1.56 * 11.41 = 17.8 A

Inputs from CEC Modules.csv for Sonali Energees USA LLC SS144H-455MB: Voc=50.4 V, beta_Voc=-0.282%/C, Isc=11.41 A, STC=455.0 W, Area=2.18 m2.

**Result:** 10 panels max on 600 V (553.7 V); 18 panels for 8 kW (422 sq ft).

## What Are the Published CEC Specifications for Sonali Energees USA LLC SS144H-455MB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Sonali Energees USA LLC SS144H-455MB.

Official California Energy Commission (NREL SAM) test parameters for Sonali Energees USA LLC SS144H-455MB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 425.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 50.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 11.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.8 V / 10.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.282 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.87% (2.18 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Sonali Energees USA LLC SS144H-455MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Sonali Energees USA LLC SS144H-455MB (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.37 kW | 329 sq ft | $1,594 | $2,696 |
| **8 kW Class** | 18 | 8.19 kW | 422 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 22 | 10.01 kW | 516 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Sonali Energees USA LLC Series?

All closely matched Sonali Energees USA LLC wattages and cosmetic trims sharing the Sonali Energees USA LLC SS144H-455MB architecture.

Sibling CEC listings grouped into the Sonali Energees USA LLC SS144H-455MB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Sonali Energees USA LLC SS144H-450MB** | 450.0 W | 420.7 W | 50.3 V | 41.6 V | 20.64% |
| **Sonali Energees USA LLC SS144H-455MB** | 455.0 W | 425.5 W | 50.4 V | 41.8 V | 20.87% |

## How Many Sonali Energees USA LLC SS144H-455MB Modules Fit in a Cold-Weather String?

Maximum series module counts for Sonali Energees USA LLC SS144H-455MB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.4V and beta_Voc=-0.282%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.8 V | 10 panels | 568.0 V | 17 panels |
| **-10 C (14 F)** | 55.37 V | 10 panels | 553.7 V | 18 panels |
| **0 C (32 F)** | 53.95 V | 11 panels | 593.5 V | 18 panels |
| **25 C (77 F STC)** | 50.4 V | 11 panels | 554.4 V | 19 panels |

## Which Cross-Brand Solar Modules Compare Closest to Sonali Energees USA LLC SS144H-455MB?

Alternative CEC solar modules from competing brands near Sonali Energees USA LLC SS144H-455MB (455.0 W), including HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s455xi/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.9% |
| [**HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455YI**](https://epri-peac.com/solar-equipment/modules/hd-hyundai-energy-solutions-co-ltd/hd-hyundai-energy-solutions-co-ltd-his-s455yi/) HD HYUNDAI ENERGY SOLUTIONS CO LTD | 455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.8% |
| [**Apollo Renewables Inc Apollo-M672BH-455TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m672bh-455tw/) Apollo Renewables Inc | 455.0 W | Tie (0 W) | 49.8 V | 21.16% | 93.5% |
| [**Bluesun Solar CoLtd BSM455M-72HPH**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-coltd/bluesun-solar-coltd-bsm455m-72hph/) Bluesun Solar CoLtd | 455.0 W | Tie (0 W) | 49.8 V | 20.97% | 92.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Sonali Energees USA LLC SS144H-455MB?

Evaluate Sonali Energees USA LLC SS144H-455MB (455.0 W STC, 50.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Sonali Energees USA LLC SS144H-455MB reaches 56.8 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 422 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (422 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Sonali Energees USA LLC SS144H-455MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Sonali Energees USA LLC SS144H-455MB 8 kW Residential Fit

Needs 18 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 425.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sonali Energees USA LLC SS144H-455MB by Sonali Energees USA LLC grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Sonali Energees USA LLC SS144H-455MB PTC wattage (425.5 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 425.5 W PTC (93.5% retention) across Sonali Energees USA LLC SS144H-455MB's 2.18 m2 aperture.

### Who should skip Sonali Energees USA LLC SS144H-455MB on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Sonali Energees USA LLC SS144H-455MB panels (422 sq ft) leave unusable roof gaps vs. HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

### What is the 1,000 V commercial string limit for Sonali Energees USA LLC SS144H-455MB?

On 1,000 V commercial inverters at -10 C (55.37 V cold Voc), Sonali Energees USA LLC SS144H-455MB fits up to 18 panels per series string.

## Related Pages

Compare Sonali Energees USA LLC equipment, HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI specs, utility payback rates, and NEC string calculators alongside Sonali Energees USA LLC SS144H-455MB.

[All Sonali Energees USA LLC Certified Solar Models](https://epri-peac.com/solar-equipment/brands/sonali-energees-usa-llc/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Sonali Energees USA LLC

- [All Sonali Energees USA LLC Specs](https://epri-peac.com/solar-equipment/brands/sonali-energees-usa-llc/)
- [Sonali Energees USA LLC SS-SHDB144-555/M](https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss-shdb144-555-m/)
- [Sonali Energees USA LLC SS144H-555MD](https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss144h-555md/)
- [Sonali Energees USA LLC SS144H-555MT](https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss144h-555mt/)
- [Sonali Energees USA LLC SS-550-144M-B](https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss-550-144m-b/)
- [Sonali Energees USA LLC SS-550-144M-W](https://epri-peac.com/solar-equipment/modules/sonali-energees-usa-llc/sonali-energees-usa-llc-ss-550-144m-w/)