title: "SOLEX ENERGY LTD SMFB60HM10-440 Specs (440.0W, 41.67V Voc)"
url: https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smfb60hm10-440/
description: "CEC datasheet for SOLEX ENERGY LTD SMFB60HM10-440: 440.0W STC, 41.67V Voc, 19-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# SOLEX ENERGY LTD SMFB60HM10-440 — CEC Solar Module Specifications

Manufacturer: [**SOLEX ENERGY LTD**](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) Registry: **CEC Verified Engineering Specification**

SOLEX ENERGY LTD SMFB60HM10-440 is a 440.0 W STC (410.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.28% efficiency, 41.67 V Voc at 25 C, and 45.01 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 410.6 W

- **Voc @ 25C** : 41.67 V

- **Efficiency** : 20.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLEX ENERGY LTD SMFB60HM10-440 Compare Against Peer CEC Listings?

How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB60HM10-440 handles rooftop heat (410.6 W PTC), 8 kW sizing, and cold winter string voltage.

SOLEX ENERGY LTD builds the SOLEX ENERGY LTD SMFB60HM10-440 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 (440.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Mid-range 41.67 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 20.81 A overcurrent floor served by a 25 A breaker.

## Where Does SOLEX ENERGY LTD SMFB60HM10-440 Fall Across Listed CEC Models?

Where SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLEX ENERGY LTD SMFB60HM10-440?

Percentile placement of SOLEX ENERGY LTD SMFB60HM10-440 across power density (202.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB60HM10-440?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB60HM10-440 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,406

### 20.28% Aperture Efficiency

Power density 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.01 V at -10 C (585.1 V string) and 45.96 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,801 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.67 * (1 + (-0.229/100) * (-10 - 25)) = 45.01 V | OCPD = 1.56 * 13.34 = 20.81 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB60HM10-440: Voc=41.67 V, beta_Voc=-0.229%/C, Isc=13.34 A, STC=440.0 W, Area=2.17 m2.

**Result:** 13 panels max on 600 V (585.1 V); 19 panels for 8 kW (444 sq ft).

## What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB60HM10-440?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB60HM10-440.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMFB60HM10-440.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 410.6 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.57 V / 12.73 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.229 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.28% (2.17 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLEX ENERGY LTD SMFB60HM10-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 327 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 444 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 537 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB60HM10-440 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMFB60HM10-440 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLEX ENERGY LTD SMFB60HM10-430** | 430.0 W | 401.1 W | 41.33 V | 34.23 V | 19.82% |
| **SOLEX ENERGY LTD SMFB60HM10-435** | 435.0 W | 405.8 W | 41.5 V | 34.4 V | 20.05% |
| **SOLEX ENERGY LTD SMFB60HM10-440** | 440.0 W | 410.6 W | 41.67 V | 34.57 V | 20.28% |
| **SOLEX ENERGY LTD SMFB60HM10-445** | 445.0 W | 415.4 W | 41.84 V | 34.74 V | 20.51% |

## How Many SOLEX ENERGY LTD SMFB60HM10-440 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLEX ENERGY LTD SMFB60HM10-440 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.67V and beta_Voc=-0.229%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.96 V | 13 panels | 597.5 V | 21 panels |
| **-10 C (14 F)** | 45.01 V | 13 panels | 585.1 V | 22 panels |
| **0 C (32 F)** | 44.06 V | 13 panels | 572.8 V | 22 panels |
| **25 C (77 F STC)** | 41.67 V | 14 panels | 583.4 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB60HM10-440?

Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W), including Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos1/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos2/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-440**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-440/) Elin Energy (Sirius PV) | 440.0 W | Tie (0 W) | 41.12 V | 20.47% | 94.2% |
| [**CertainTeed CTM10440HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/) CertainTeed | 440.0 W | Tie (0 W) | 41.02 V | 20.37% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB60HM10-440?

Evaluate SOLEX ENERGY LTD SMFB60HM10-440 (440.0 W STC, 41.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB60HM10-440 reaches 45.96 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (444 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB60HM10-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLEX ENERGY LTD SMFB60HM10-440 8 kW Residential Fit

Needs 19 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 410.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMFB60HM10-440 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SOLEX ENERGY LTD SMFB60HM10-440?

Multiplying SOLEX ENERGY LTD SMFB60HM10-440's 13.34 A short-circuit current by 1.56 equals 20.81 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can SOLEX ENERGY LTD SMFB60HM10-440 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.01 V cold Voc at 14 F and handles 13.34 A Isc; string inverters cap SOLEX ENERGY LTD SMFB60HM10-440 at 13 panels on 600 V.

### Is SOLEX ENERGY LTD SMFB60HM10-440 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLEX ENERGY LTD SMFB60HM10-440 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

## Related Pages

Compare SOLEX ENERGY LTD equipment, Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 specs, utility payback rates, and NEC string calculators alongside SOLEX ENERGY LTD SMFB60HM10-440.

[All SOLEX ENERGY LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLEX ENERGY LTD

- [All SOLEX ENERGY LTD Specs](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/)
- [SOLEX ENERGY LTD SMB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-555/)
- [SOLEX ENERGY LTD SMF72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-555/)
- [SOLEX ENERGY LTD SMFB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smfb72hm10-555/)
- [SOLEX ENERGY LTD SMB72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-535/)
- [SOLEX ENERGY LTD SMF72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-535/)