Manufacturer: [**SOLEX ENERGY LTD**](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) Registry: **CEC Verified Engineering Specification**

SOLEX ENERGY LTD SMFB54HM10-410 is a 410.0 W STC (383.0 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.03% efficiency, 38.99 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 410.0 W

- **PTC Wattage** : 383.0 W

- **Voc @ 25C** : 38.99 V

- **Efficiency** : 21.03%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLEX ENERGY LTD SMFB54HM10-410 Compare Against Peer CEC Listings?

How SOLEX ENERGY LTD SOLEX ENERGY LTD SMFB54HM10-410 handles rooftop heat (383.0 W PTC), 8 kW sizing, and cold winter string voltage.

SOLEX ENERGY LTD builds the SOLEX ENERGY LTD SMFB54HM10-410 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 (410.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 38.99 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.06 A overcurrent floor served by a 25 A breaker.

## Where Does SOLEX ENERGY LTD SMFB54HM10-410 Fall Across Listed CEC Models?

Where SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLEX ENERGY LTD SMFB54HM10-410?

Percentile placement of SOLEX ENERGY LTD SMFB54HM10-410 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMFB54HM10-410?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMFB54HM10-410 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #8,539 / 21,677

### Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

### 21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.01 V at -20 C (13 max).

 8 kW Reference Array

### 20 Panels = 8,200 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,660 W PTC; NEC 690.8 OCPD floor is 21.06 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.99 * (1 + (-0.229/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.5 = 21.06 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMFB54HM10-410: Voc=38.99 V, beta_Voc=-0.229%/C, Isc=13.5 A, STC=410.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (589.7 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for SOLEX ENERGY LTD SMFB54HM10-410?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMFB54HM10-410.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMFB54HM10-410.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 383.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.99 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.85 V / 12.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.229 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.03% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLEX ENERGY LTD SMFB54HM10-410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.15 kW | 315 sq ft | $1,539 | $2,603 |
| **8 kW Class** | 20 | 8.2 kW | 420 sq ft | $2,052 | $3,470 |
| **10 kW Class** | 25 | 10.25 kW | 525 sq ft | $2,565 | $4,338 |

## Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMFB54HM10-410 architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMFB54HM10-410 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLEX ENERGY LTD SMFB54HM10-400** | 400.0 W | 373.4 W | 38.57 V | 31.47 V | 20.51% |
| **SOLEX ENERGY LTD SMFB54HM10-405** | 405.0 W | 378.2 W | 38.74 V | 31.64 V | 20.77% |
| **SOLEX ENERGY LTD SMFB54HM10-410** | 410.0 W | 383.0 W | 38.99 V | 31.85 V | 21.03% |
| **SOLEX ENERGY LTD SMFB54HM10-415** | 415.0 W | 387.8 W | 39.16 V | 32.02 V | 21.28% |
| **SOLEX ENERGY LTD SMFB54HM10-420** | 420.0 W | 392.6 W | 39.31 V | 32.21 V | 21.54% |

## How Many SOLEX ENERGY LTD SMFB54HM10-410 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLEX ENERGY LTD SMFB54HM10-410 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.99V and beta_Voc=-0.229%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.01 V | 13 panels | 559.1 V | 23 panels |
| **-10 C (14 F)** | 42.12 V | 14 panels | 589.7 V | 23 panels |
| **0 C (32 F)** | 41.22 V | 14 panels | 577.1 V | 24 panels |
| **25 C (77 F STC)** | 38.99 V | 15 panels | 584.9 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMFB54HM10-410?

Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W), including Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mf10-410w-usaptos1/) Aptos Solar Technology LLC | 410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| [**Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-mf10-410w-usaptos2/) Aptos Solar Technology LLC | 410.0 W | Tie (0 W) | 37.7 V | 21.13% | 94.3% |
| [**Auxin Solar AXN10M410B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m410b/) Auxin Solar | 410.0 W | Tie (0 W) | 37.54 V | 21.64% | 94.0% |
| [**DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M**](https://epri-peac.com/solar-equipment/modules/dongguan-sunworth-solar-energy-co-ltd/dongguan-sunworth-solar-energy-co-ltd-sw410m/) DONGGUAN SUNWORTH SOLAR ENERGY CO LTD | 410.0 W | Tie (0 W) | 37.51 V | 21.58% | 94.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMFB54HM10-410?

Evaluate SOLEX ENERGY LTD SMFB54HM10-410 (410.0 W STC, 38.99 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMFB54HM10-410 reaches 43.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMFB54HM10-410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLEX ENERGY LTD SMFB54HM10-410 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMFB54HM10-410 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for SOLEX ENERGY LTD SMFB54HM10-410?

Multiplying SOLEX ENERGY LTD SMFB54HM10-410's 13.5 A short-circuit current by 1.56 equals 21.06 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can SOLEX ENERGY LTD SMFB54HM10-410 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 13.5 A Isc; string inverters cap SOLEX ENERGY LTD SMFB54HM10-410 at 14 panels on 600 V.

### Is SOLEX ENERGY LTD SMFB54HM10-410 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLEX ENERGY LTD SMFB54HM10-410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

## Related Pages

Compare SOLEX ENERGY LTD equipment, Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1 specs, utility payback rates, and NEC string calculators alongside SOLEX ENERGY LTD SMFB54HM10-410.

[All SOLEX ENERGY LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLEX ENERGY LTD

- [All SOLEX ENERGY LTD Specs](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/)
- [SOLEX ENERGY LTD SMB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-555/)
- [SOLEX ENERGY LTD SMF72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-555/)
- [SOLEX ENERGY LTD SMFB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smfb72hm10-555/)
- [SOLEX ENERGY LTD SMB72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-535/)
- [SOLEX ENERGY LTD SMF72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-535/)