CEC PV Module

# SOLEX ENERGY LTD SMB60HM10-460 — CEC Solar Module Specifications

Manufacturer: [**SOLEX ENERGY LTD**](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) Registry: **CEC Verified Engineering Specification**

SOLEX ENERGY LTD SMB60HM10-460 is a 460.0 W STC (428.8 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 21.2% efficiency, 42.31 V Voc at 25 C, and 45.69 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 460.0 W

- **PTC Wattage** : 428.8 W

- **Voc @ 25C** : 42.31 V

- **Efficiency** : 21.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLEX ENERGY LTD SMB60HM10-460 Compare Against Peer CEC Listings?

How SOLEX ENERGY LTD SOLEX ENERGY LTD SMB60HM10-460 handles rooftop heat (428.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLEX ENERGY LTD SMB60HM10-460 exhibits 13.69 A short-circuit current, requiring a 21.36 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,199 of 21,677 (50.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.1 m2 for an 8 kW system (22 panels for 10 kW). Mid-range 42.31 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does SOLEX ENERGY LTD SMB60HM10-460 Fall Across Listed CEC Models?

Where SOLEX ENERGY LTD SMB60HM10-460 (460.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define SOLEX ENERGY LTD SMB60HM10-460?

Percentile placement of SOLEX ENERGY LTD SMB60HM10-460 across power density (212.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMB60HM10-460?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLEX ENERGY LTD SMB60HM10-460 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #5,199 / 21,677

### Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,580

### 21.2% Aperture Efficiency

Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.69 V at -10 C (594.0 V string) and 46.65 V at -20 C (12 max).

 8 kW Reference Array

### 18 Panels = 8,280 W STC

Occupies 39.1 m2 (420 sq ft) producing 7,718 W PTC; NEC 690.8 OCPD floor is 21.36 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.31 * (1 + (-0.228/100) * (-10 - 25)) = 45.69 V | OCPD = 1.56 * 13.69 = 21.36 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMB60HM10-460: Voc=42.31 V, beta_Voc=-0.228%/C, Isc=13.69 A, STC=460.0 W, Area=2.17 m2.

**Result:** 13 panels max on 600 V (594.0 V); 18 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for SOLEX ENERGY LTD SMB60HM10-460?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLEX ENERGY LTD SMB60HM10-460.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMB60HM10-460.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 428.8 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 42.31 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 35.21 V / 13.07 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.228 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.2% (2.17 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLEX ENERGY LTD SMB60HM10-460 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLEX ENERGY LTD SMB60HM10-460 (460.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.44 kW | 327 sq ft | $1,612 | $2,726 |
| **8 kW Class** | 18 | 8.28 kW | 420 sq ft | $2,072 | $3,504 |
| **10 kW Class** | 22 | 10.12 kW | 514 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

All closely matched SOLEX ENERGY LTD wattages and cosmetic trims sharing the SOLEX ENERGY LTD SMB60HM10-460 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMB60HM10-460 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLEX ENERGY LTD SMB60HM10-450** | 450.0 W | 419.2 W | 41.99 V | 34.89 V | 20.74% |
| **SOLEX ENERGY LTD SMB60HM10-455** | 455.0 W | 424.0 W | 42.16 V | 35.06 V | 20.97% |
| **SOLEX ENERGY LTD SMB60HM10-460** | 460.0 W | 428.8 W | 42.31 V | 35.21 V | 21.2% |
| **SOLEX ENERGY LTD SMB60HM10-465** | 465.0 W | 433.6 W | 42.44 V | 35.34 V | 21.43% |

## How Many SOLEX ENERGY LTD SMB60HM10-460 Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLEX ENERGY LTD SMB60HM10-460 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=42.31V and beta_Voc=-0.228%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.65 V | 12 panels | 559.8 V | 21 panels |
| **-10 C (14 F)** | 45.69 V | 13 panels | 594.0 V | 21 panels |
| **0 C (32 F)** | 44.72 V | 13 panels | 581.4 V | 22 panels |
| **25 C (77 F STC)** | 42.31 V | 14 panels | 592.3 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMB60HM10-460?

Alternative CEC solar modules from competing brands near SOLEX ENERGY LTD SMB60HM10-460 (460.0 W), including Boviet Solar Technology Co Ltd BVM7610M-460-H-HC.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7610M-460-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7610m-460-h-hc/) Boviet Solar Technology Co Ltd | 460.0 W | Tie (0 W) | 42.49 V | 21.9% | 94.1% |
| [**EMMVEE Photovoltaic Power Private Limited E460HCM120-BT**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e460hcm120-bt/) EMMVEE Photovoltaic Power Private Limited | 460.0 W | Tie (0 W) | 42.52 V | 21.9% | 94.1% |
| [**Aptos Solar Technology LLC DNA-120-MF10-460W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-460w/) Aptos Solar Technology LLC | 460.0 W | Tie (0 W) | 41.7 V | 21.3% | 93.8% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-460**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-460/) Elin Energy (Sirius PV) | 460.0 W | Tie (0 W) | 41.52 V | 21.4% | 94.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMB60HM10-460?

Evaluate SOLEX ENERGY LTD SMB60HM10-460 (460.0 W STC, 42.31 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMB60HM10-460 reaches 46.65 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMB60HM10-460 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLEX ENERGY LTD SMB60HM10-460 8 kW Residential Fit

Needs 18 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7610M-460-H-HC.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 428.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMB60HM10-460 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is SOLEX ENERGY LTD SMB60HM10-460 PTC wattage (428.8 W) lower than STC (460.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 428.8 W PTC (93.2% retention) across SOLEX ENERGY LTD SMB60HM10-460's 2.17 m2 aperture.

### Who should skip SOLEX ENERGY LTD SMB60HM10-460 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 SOLEX ENERGY LTD SMB60HM10-460 panels (420 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM7610M-460-H-HC.

### What is the 1,000 V commercial string limit for SOLEX ENERGY LTD SMB60HM10-460?

On 1,000 V commercial inverters at -10 C (45.69 V cold Voc), SOLEX ENERGY LTD SMB60HM10-460 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SOLEX ENERGY LTD SMB60HM10-460.

## Related Pages

Compare SOLEX ENERGY LTD equipment, Boviet Solar Technology Co Ltd BVM7610M-460-H-HC specs, utility payback rates, and NEC string calculators alongside SOLEX ENERGY LTD SMB60HM10-460.

[All SOLEX ENERGY LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLEX ENERGY LTD

- [All SOLEX ENERGY LTD Specs](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/)
- [SOLEX ENERGY LTD SMB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-555/)
- [SOLEX ENERGY LTD SMF72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-555/)
- [SOLEX ENERGY LTD SMFB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smfb72hm10-555/)
- [SOLEX ENERGY LTD SMB72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-535/)
- [SOLEX ENERGY LTD SMF72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-535/)