CEC PV Module

# SOLEX ENERGY LTD SMB60HM10-440 — CEC Solar Module Specifications

Manufacturer: [**SOLEX ENERGY LTD**](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) Registry: **CEC Verified Engineering Specification**

SOLEX ENERGY LTD SMB60HM10-440 is a 440.0 W STC (409.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.28% efficiency, 41.67 V Voc at 25 C, and 45.0 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 440.0 W

- **PTC Wattage** : 409.6 W

- **Voc @ 25C** : 41.67 V

- **Efficiency** : 20.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does SOLEX ENERGY LTD SMB60HM10-440 Compare Against Peer CEC Listings?

Solar engineering breakdown for SOLEX ENERGY LTD SMB60HM10-440: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 440.0 W STC and 409.6 W PTC, SOLEX ENERGY LTD SMB60HM10-440 sits +55.0 W vs all-CEC median (top 31.6%; higher than 68.4% of peers) among 21,677 listed modules. Power density reaches 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). Mid-range 41.67 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 rates 440.0 W.

## Where Does SOLEX ENERGY LTD SMB60HM10-440 Fall Across Listed CEC Models?

Distribution marker showing SOLEX ENERGY LTD SMB60HM10-440 (440.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define SOLEX ENERGY LTD SMB60HM10-440?

Dataset percentiles tracking SOLEX ENERGY LTD SMB60HM10-440 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for SOLEX ENERGY LTD SMB60HM10-440?

Benchmark highlights for SOLEX ENERGY LTD SMB60HM10-440 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

### Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,406

### 20.28% Aperture Efficiency

Power density 202.8 W/m2 (0.37 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.0 V at -10 C (585.0 V string) and 45.95 V at -20 C (13 max).

 8 kW Reference Array

### 19 Panels = 8,360 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,782 W PTC; NEC 690.8 OCPD floor is 20.81 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.67 * (1 + (-0.228/100) * (-10 - 25)) = 45.0 V | OCPD = 1.56 * 13.34 = 20.81 A

Inputs from CEC Modules.csv for SOLEX ENERGY LTD SMB60HM10-440: Voc=41.67 V, beta_Voc=-0.228%/C, Isc=13.34 A, STC=440.0 W, Area=2.17 m2.

**Result:** 13 panels max on 600 V (585.0 V); 19 panels for 8 kW (444 sq ft).

## What Are the Published CEC Specifications for SOLEX ENERGY LTD SMB60HM10-440?

Official CEC datasheet figures for SOLEX ENERGY LTD SMB60HM10-440 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for SOLEX ENERGY LTD SMB60HM10-440.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 409.6 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.57 V / 12.73 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.228 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.28% (2.17 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many SOLEX ENERGY LTD SMB60HM10-440 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many SOLEX ENERGY LTD SMB60HM10-440 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.16 kW | 327 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 19 | 8.36 kW | 444 sq ft | $2,092 | $3,538 |
| **10 kW Class** | 23 | 10.12 kW | 537 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This SOLEX ENERGY LTD Series?

Consolidated SOLEX ENERGY LTD wattage variants sharing the SOLEX ENERGY LTD SMB60HM10-440 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the SOLEX ENERGY LTD SMB60HM10-440 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **SOLEX ENERGY LTD SMB60HM10-430** | 430.0 W | 400.1 W | 41.33 V | 34.23 V | 19.82% |
| **SOLEX ENERGY LTD SMB60HM10-435** | 435.0 W | 404.9 W | 41.5 V | 34.4 V | 20.05% |
| **SOLEX ENERGY LTD SMB60HM10-440** | 440.0 W | 409.6 W | 41.67 V | 34.57 V | 20.28% |
| **SOLEX ENERGY LTD SMB60HM10-445** | 445.0 W | 414.4 W | 41.84 V | 34.74 V | 20.51% |

## How Many SOLEX ENERGY LTD SMB60HM10-440 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on SOLEX ENERGY LTD SMB60HM10-440 (45.0 V at 14 F).

Computed from Voc=41.67V and beta_Voc=-0.228%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.95 V | 13 panels | 597.4 V | 21 panels |
| **-10 C (14 F)** | 45.0 V | 13 panels | 585.0 V | 22 panels |
| **0 C (32 F)** | 44.05 V | 13 panels | 572.6 V | 22 panels |
| **25 C (77 F STC)** | 41.67 V | 14 panels | 583.4 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to SOLEX ENERGY LTD SMB60HM10-440?

Competing CEC solar panels closest to SOLEX ENERGY LTD SMB60HM10-440 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos1/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-mf10-440w-usaptos2/) Aptos Solar Technology LLC | 440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| [**Elin Energy (Sirius PV) ELNSM60M-HC-440**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm60m-hc-440/) Elin Energy (Sirius PV) | 440.0 W | Tie (0 W) | 41.12 V | 20.47% | 94.2% |
| [**CertainTeed CTM10440HC11-06**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-ctm10440hc11-06/) CertainTeed | 440.0 W | Tie (0 W) | 41.02 V | 20.37% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for SOLEX ENERGY LTD SMB60HM10-440?

Evaluate SOLEX ENERGY LTD SMB60HM10-440 (440.0 W STC, 41.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), SOLEX ENERGY LTD SMB60HM10-440 reaches 45.95 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (444 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLEX ENERGY LTD SMB60HM10-440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### SOLEX ENERGY LTD SMB60HM10-440 8 kW Residential Fit

Needs 19 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 409.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLEX ENERGY LTD SMB60HM10-440 by SOLEX ENERGY LTD grounded in CEC test data and NEC 690.7/690.8 limits.

### How many SOLEX ENERGY LTD SMB60HM10-440 panels fit on a 600 V winter solar string?

At -10 C (14 F), SOLEX ENERGY LTD SMB60HM10-440 cold Voc rises from 41.67 V to 45.0 V (beta_Voc -0.228%/C), capping a 600 V string at 13 panels (585.0 V).

### How much roof area does an 8 kW array of SOLEX ENERGY LTD SMB60HM10-440 need?

An 8 kW DC system uses 19 SOLEX ENERGY LTD SMB60HM10-440 modules (8,360 W STC / 7,782 W PTC), covering roughly 444 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

### How does SOLEX ENERGY LTD SMB60HM10-440 compare against Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1?

SOLEX ENERGY LTD SMB60HM10-440 outputs 440.0 W STC (41.67 V Voc, rank #6,418 of 21,677), while Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare SOLEX ENERGY LTD equipment, Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 specs, utility payback rates, and NEC string calculators alongside SOLEX ENERGY LTD SMB60HM10-440.

[All SOLEX ENERGY LTD Certified Solar Models](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From SOLEX ENERGY LTD

- [All SOLEX ENERGY LTD Specs](https://epri-peac.com/solar-equipment/brands/solex-energy-ltd/)
- [SOLEX ENERGY LTD SMB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-555/)
- [SOLEX ENERGY LTD SMF72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-555/)
- [SOLEX ENERGY LTD SMFB72HM10-555](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smfb72hm10-555/)
- [SOLEX ENERGY LTD SMB72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smb72hm10-535/)
- [SOLEX ENERGY LTD SMF72HM10-535](https://epri-peac.com/solar-equipment/modules/solex-energy-ltd/solex-energy-ltd-smf72hm10-535/)